MTU Onsite Energy Corpo...
|
| Part No. |
MTU12V4000DS1550
|
| OCR Text |
... fuel consumption ? l/hr g/kwh at 100% of power rating: 420.4 201 at 75% of power rating: 312.2 199 at 50% of power rating: 221.7 212 // liquid capacity (lubrication) total oil system capacity: l 260 engine jacket wat... |
| Description |
DIESEL GENERATOR SET
|
| File Size |
811.15K /
5 Page |
View
it Online |
Download Datasheet
|
| |
|
 |
MTU Onsite Energy Corpo...
|
| Part No. |
MTU12V4000DS1650
|
| OCR Text |
... fuel consumption ? l/hr g/kwh at 100% of power rating: 342.2 200 at 75% of power rating: 274.6 214 at 50% of power rating: 200.2 234 // liquid capacity (lubrication) total oil system capacity: l 260 engine jacket water ca... |
| Description |
DIESEL GENERATOR SET
|
| File Size |
658.99K /
6 Page |
View
it Online |
Download Datasheet
|
| |
|
 |
MTU Onsite Energy Corpo...
|
| Part No. |
MTU16V2000DS1000-3B
|
| OCR Text |
...el consumption ? gal/hr l/hr g/kwh at 100% of power rating: 56 214 219 at 75% of power rating: 42 158 216 at 50% of power rating: 28 106 217 // cooling/radiator system ambient capacity of radiator: c 40 max. restriction o... |
| Description |
DIESEL GENERATOR SET
|
| File Size |
1,043.68K /
4 Page |
View
it Online |
Download Datasheet
|
| |
|
 |
MTU Onsite Energy Corpo...
|
| Part No. |
MTU16V2000DS1000
|
| OCR Text |
...el consumption ? gal/hr l/hr g/kwh at 100% of power rating: 51 193 198 at 75% of power rating: 38 145 198 at 50% of power rating: 26 99 203 // cooling/radiator system ambient capacity of radiator: c 40 (optional 50) ? max... |
| Description |
DIESEL GENERATOR SET
|
| File Size |
1,044.43K /
4 Page |
View
it Online |
Download Datasheet
|
| |
|
 |
MTU Onsite Energy Corpo...
|
| Part No. |
MTU16V2000DS1050
|
| OCR Text |
...el consumption ? gal/hr l/hr g/kwh at 100% of power rating: 56 212 198 at 75% of power rating: 42 158 196 at 50% of power rating: 28 108 201 // cooling/radiator system water pump capacity: l/min (gpm) 667 (176) heat rej... |
| Description |
DIESEL GENERATOR SET
|
| File Size |
860.11K /
4 Page |
View
it Online |
Download Datasheet
|
| |
|
 |
MTU Onsite Energy Corpo...
|
| Part No. |
MTU16V2000DS1140
|
| OCR Text |
...el consumption ? gal/hr l/hr g/kwh at 100% of power rating: 57 214 200 at 75% of power rating: 42 158 196 at 50% of power rating: 28 108 201 // cooling/radiator system water pump capacity: l/min (gpm) 667 (176) heat rej... |
| Description |
DIESEL GENERATOR SET
|
| File Size |
1,227.37K /
4 Page |
View
it Online |
Download Datasheet
|
| |
|
 |
MTU Onsite Energy Corpo...
|
| Part No. |
MTU18V2000DS1290
|
| OCR Text |
...el consumption ? gal/hr l/hr g/kwh at 100% of power rating: 71 269 203 at 75% of power rating: 53 199 200 at 50% of power rating: 35 133 201 // cooling/radiator system water pump capacity: l/min (gpm) 667 (176) heat rej... |
| Description |
WATER CHARGE-AIR COOLING
|
| File Size |
1,202.02K /
4 Page |
View
it Online |
Download Datasheet
|
|

Price and Availability
|