19-2443; Rev 1; 2/03 50V Isolated, 3.0V to 5.5V, 250kbps, 2 Tx/2 Rx, RS-232 Transceiver General Description The MAX3250 is a 3.0V to 5.5V powered, 50V isolated EIA/TIA-232 and V.28/V.24 communications interface with high data-rate capabilities. The MAX3250 is a dual die part that operates with up to 50V difference between the RS-232 side and the logic side (ISOCOM to GND). This makes the device ideal for operation in noisy conditions with high common-mode voltages. This feature prevents damage to the device if RS-232 lines are inadvertently short-circuited to a +24V or 48V power bus. The MAX3250 is powered by a single 3V to 5.5V supply on the logic side. Power is transferred from the logic side to the isolated side by 100V external capacitors. The MAX3250 has two receivers (Rx) and two drivers (Tx) and is guaranteed to run at data rates of 250kbps while maintaining RS-232 output levels. The transceivers have a proprietary low-dropout transmitter output stage, delivering true RS-232 performance from a 3V to 5.5V supply with a dual charge pump. The device features a FAULT open-drain output to signal an excessive isolated-side voltage condition on any of the RS232 inputs. This output can drive an alarm LED or can be monitored by the processor to prevent operation under these conditions. The receiver outputs are high impedance in shutdown, allowing multiple interfaces (IrDA, RS-232, RS-485) to be connected to the same UART. The MAX3250 is available in a space-saving 28-pin SSOP package. o 50V Isolation o 20A Supply Current in Shutdown o 250kbps Guaranteed Data Rate o FAULT Output o High-Impedance Transmitter and Receiver Outputs in Shutdown o Space-Saving SSOP Package o Inductorless/Transformerless Design Simplifies EMI Compliance o Low-Cost Replacement for Opto-Isolated Transceivers o Meets EIA/TIA-232 Specifications Down to 3.0V Features MAX3250 Ordering Information PART MAX3250CAI MAX3250EAI TEMP RANGE 0C to +70C -40C to +85C PIN-PACKAGE 28 SSOP 28 SSOP Pin Configuration TOP VIEW C1- 1 R1OUT 2 R2OUT 3 T1IN 4 T2IN 5 N.C. 6 N.C. 7 C1+ 8 C3+ 9 V+ 10 C3- 11 C4+ 12 C4- 13 28 VCC 27 C226 GND 25 FAULT 24 SHDN Applications Industrial Control Programmable Logic Controller Point-of-Sale Equipment PC-to-Router Connections Diagnostic Ports Telecom Equipment MAX3250 23 N.C. 22 N.C. 21 C2+ 20 ISOVCC 19 R1IN 18 R2IN 17 T1OUT 16 T2OUT 15 ISOCOM Typical Operating Circuit appears at end of data sheet. V- 14 SSOP ________________________________________________________________ Maxim Integrated Products 1 For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at 1-888-629-4642, or visit Maxim's website at www.maxim-ic.com. 50V Isolated, 3.0V to 5.5V, 250kbps, 2 TX/2 RX, RS-232 Transceiver MAX3250 ABSOLUTE MAXIMUM RATINGS All Voltages Referenced to GND, Unless Otherwise Noted. VCC ...........................................................................-0.3V to +6V ISOCOM...............................................................................80V ISOVCC to ISOCOM..................................................-0.3V to +6V V+ to ISOCOM (Note 1)............................................-0.3V to +7V V- to ISOCOM (Note 1)............................................+0.3V to -7V V+ + |V-| (Note 1) ...................................................................13V Input Voltages T_IN, SHDN ...........................................................-0.3V to +6V R_IN to ISOCOM...............................................................25V Output Voltages T_OUT to ISOCOM ........................................................13.2V R_OUT .....................................................-0.3V to (VCC + 0.3V) FAULT....................................................................-0.3V to +6V C1-, C2- ......................................................-0.3V to (VCC + 0.3V) C1+, C2+, C3+, C3-, C4+, C4to ISOCOM ......................................-0.3V to (ISOVCC + 0.3V) T_OUT Current ..............30mA (continuous), 50mA (peak, 10s) R_IN Current..................30mA (continuous), 50mA (peak, 10s) ISOCOM Current ...........30mA (continuous), 50mA (peak, 10s) Short-Circuit Duration T_OUT to ISOCOM .................Continuous Continuous Power Dissipation (TA = +70C) 28-Pin SSOP (derate 9.5mW/C above +70C) ...........762mW Operating Temperature Ranges MAX3250CAI .....................................................0C to +70C MAX3250EAI...................................................-40C to +85C Storage Temperature Range .............................-65C to +150C Lead Temperature (soldering, 10s) .................................+300C Note 1: V+ and V- can have a maximum magnitude of 7V, but their absolute difference cannot exceed 13V. Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. ELECTRICAL CHARACTERISTICS (VCC = 3.0V to 5.5V, see Typical Operating Circuit and Table 1 for capacitor values, ISOCOM = GND, TA = TMIN to TMAX, unless otherwise noted. Typical values are at VCC = 3.3V and TA = +25C.) (Note 2) PARAMETER DC CHARACTERISTICS Supply Current Supply Current Shutdown Maximum Ground Differential Isolation Resistance LOGIC INPUTS Input Logic Low Input Logic High Transmitter Input Hysteresis Input Leakage Current RECEIVER OUTPUTS Output Leakage Current Output Voltage Low Output Voltage High FAULT OUTPUT Output Voltage Low (Open Drain) Output Leakage Current FAULT Trip Level SHDN = GND IOUT = 1.6mA IOUT = -1.0mA VCC - 0.6 VCC - 0.1 -10 0.05 +10 0.4 A V V T_IN, SHDN -1 T_IN, SHDN T_IN, SHDN VCC = 3.3V VCC = 5.0V 2.0 2.4 0.5 0.01 +1 0.8 V V V A SHDN = VCC, no load SHDN = GND, VISOCOM = GND SHDN = GND, VISOCOM = 50V |VGND - VISOCOM| Between GND and ISOCOM 60 15 20 35 45 350 50 mA A V k CONDITIONS MIN TYP MAX UNITS IOUT = 5mA FAULT not asserted |VGND - VISOCOM| 55 0.4 1 V A V 2 _______________________________________________________________________________________ 50V Isolated, 3.0V to 5.5V, 250kbps, 2 TX/2 RX, RS-232 Transceiver ELECTRICAL CHARACTERISTICS (continued) (VCC = 3.0V to 5.5V, see Typical Operating Circuit and Table 1 for capacitor values, ISOCOM = GND, TA = TMIN to TMAX, unless otherwise noted. Typical values are at VCC = 3.3V and TA = +25C.) (Note 2) PARAMETER RECEIVER INPUTS (relative to ISOCOM) Input Voltage Range Input Threshold Low Input Threshold High Input Hysteresis Input Resistance Output Voltage Swing Output Resistance Output Short-Circuit Current Output Leakage Current VCC = 0 or 3V to 5.5V, T_OUT = 12V, SHDN = GND TA = +25C All transmitter outputs loaded with 3k to ISOCOM ISOVCC = V+ = V- = 0V, T_OUT = 2V 3 5.0 300 -60 -25 TRANSMITTER OUTPUTS (relative to ISOCOM) 5.4 10M +60 +25 V mA A TA = +25C TA = +25C VCC = 3.3V VCC = 5.0V VCC = 3.3V VCC = 5.0V 2.4 2.4 -25 1.2 1.3 1.6 1.7 0.5 5 7 +25 0.6 0.8 V V V V k CONDITIONS MIN TYP MAX UNITS MAX3250 TIMING CHARACTERISTICS (VCC = 3.0V to 5.5V, see Typical Operating Circuit and Table 1 for capacitor values, ISOCOM = GND, TA = TMIN to TMAX, unless otherwise noted. Typical values are at VCC = 3.3V and TA = +25C.) PARAMETER Maximum Data Rate Receiver Propagation Delay Receiver Skew Transmitter Skew CONDITIONS RL = 3k, CL = 1000pF to ISOCOM, one transmitter R_IN to R_OUT, CL = 150pF to GND |tPHL - tPLH| |tPHL - tPLH| (Note 3) VCC = 3.3V, TA = +25C, RL = 3k to 7k to ISOCOM, measured from +3V to -3V or -3V to +3V CL = 150pF to 1000pF to ISOCOM CL = 150pF to 2500pF to ISOCOM 6 4 0.3 0.5 VISOCOM = GND VISOCOM = 50V 300 350 MIN 250 0.4 100 120 30 V/s 30 s s s TYP MAX UNITS kbps s ns ns Transition-Region Slew Rate FAULT Propagation Delay Time to Shutdown Time to Exit Shutdown Note 2: All currents into the device are positive; all currents out of the device are negative. All voltages are referenced to device ground, unless otherwise noted. Note 3: Transmitter skew is measured at the transmitter zero crosspoints. _______________________________________________________________________________________ 3 50V Isolated, 3.0V to 5.5V, 250kbps, 2 TX/2 RX, RS-232 Transceiver MAX3250 Typical Operating Characteristics (VCC = 3.3V, 250kbps data rate, see Typical Operating Circuit and Table 1 for capacitor values, all transmitters loaded with 3k and CL to ISOCOM, TA = +25C, unless otherwise noted.) TRANSMITTER OUTPUT VOLTAGE vs. LOAD CAPACITANCE MAX3250 toc01 SLEW RATE vs. LOAD CAPACITANCE MAX3250 toc02 OPERATING SUPPLY CURRENT vs. LOAD CAPACITANCE 80 SUPPLY CURRENT (mA) 70 60 50 40 30 20 120kbps 20kbps 250kbps T1 TRANSMITTING AT 250kbps T2 TRANSMITTING AT 20kbps MAX3250 toc03 8 TRANSMITTER OUTPUT VOLTAGE (V) 6 VOUT+ 4 2 0 -2 -4 -6 0 1000 2000 3000 4000 VOUTT1 TRANSMITTING AT 250kbps T2 TRANSMITTING AT 20kbps 30 25 SLEW RATE (V/s) 20 15 10 5 FOR DATA RATES UP TO 250kbps 0 +SLEW -SLEW 90 10 0 4000 5000 0 1000 2000 3000 4000 5000 5000 0 1000 2000 3000 LOAD CAPACITANCE (pF) LOAD CAPACITANCE (pF) LOAD CAPACITANCE (pF) TIME TO EXIT SHUTDOWN VISOCOM = 0V SHUTDOWN CURRENT vs. TEMPERATURE SHDN 5V/div SUPPLY CURRENT (A) ISOCOM = -50V MAX3250 toc05 MAX3250 toc04 400 300 200 100 0 -100 -200 -300 ISOCOM = +50V TOUT 5V/div ISOCOM = 0V 100s/div -40 -15 10 35 60 85 TEMPERATURE (C) PEAK GROUND OFFSET VOLTAGE vs. FREQUENCY VCC = 5V 50 PEAK GROUND OFFSET (V) 40 30 20 10 0 0 100 200 300 400 500 600 VCC = 3.3V MAX3250 toc06 COMMON-MODE FAULT RESPONSE MAX3250 toc07 60 ISOCOM 50V/div FAULT 5V/div 4ms/div FREQUENCY (Hz) 4 _______________________________________________________________________________________ 50V Isolated, 3.0V to 5.5V, 250kbps, 2 TX/2 RX, RS-232 Transceiver Pin Description PIN 1 2 3 4 5 6, 22, 23 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 24 25 26 27 28 NAME C1R1OUT R2OUT T1IN T2IN N.C. N.C. C1+ C3+ V+ C3C4+ C4VISOCOM T2OUT T1OUT R2IN R1IN ISOVCC C2+ SHDN FAULT GND C2VCC FUNCTION Negative Terminal of the Power Isolation Capacitor. Connect a 100V capacitor from C1- to C1+. See Table 1 for values. TTL/CMOS Receiver Output TTL/CMOS Receiver Output TTL/CMOS Transmitter Input TTL/CMOS Transmitter Input No Connection. Not internally connected. No Connection. Leave unconnected or connect to ISOCOM. Positive Terminal of the Power Isolation Capacitor. Connect a 100V capacitor from C1+ to C1-. See Table 1 for values. Positive Terminal of the Voltage-Doubler Charge-Pump Capacitor. Connect a 0.1F capacitor from C3+ to C3-. +5.5V Generated by the Charge Pump, Referenced to ISOCOM. Bypass V+ to ISOCOM with a 0.47F capacitor. Negative Terminal of the Voltage-Doubler Charge-Pump Capacitor. Connect a 0.1F capacitor from C3- to C3+. Positive Terminal of the Inverting Charge-Pump Capacitor. Connect a 0.47F capacitor from C4+ to C4-. Negative Terminal of the Inverting Charge-Pump Capacitor. Connect a 0.47F capacitor from C4- to C4+. -5.5V Generated by the Charge Pump, Referenced to ISOCOM. Bypass V- to ISOCOM with a 0.47F capacitor. Isolated Ground RS-232 Transmitter Output RS-232 Transmitter Output RS-232 Receiver Input RS-232 Receiver Input Internally Generated Isolated Power-Supply Voltage, Referenced to ISOCOM. Bypass ISOVCC to ISOCOM with a 1F capacitor. Positive Terminal of the Power Isolation Capacitor. Connect a 100V capacitor from C2+ to C2-. See Table 1 for values. Shutdown Control. Drive SHDN low to enter low-power shutdown mode. Drive SHDN high or connect to VCC for normal operation. Overvoltage Indicator. Active low, open drain. Ground Negative Terminal of the Power Isolation Capacitor. Connect a 100V capacitor from C2- to C2+. See Table 1 for values. 3.0V to 5.5V Supply Voltage. Bypass VCC to GND with a 1F capacitor. MAX3250 _______________________________________________________________________________________ 5 50V Isolated, 3.0V to 5.5V, 250kbps, 2 TX/2 RX, RS-232 Transceiver MAX3250 TIN1 TOUT1 ROUT1 RIN1 TIN2 TOUT2 ROUT2 RIN2 SHDN FAULT OSC ISOVCC V+ MAX3250 VCC RS-232 CHARGE PUMP C3+ C3C4+ C4V- FAULT DETECTOR POWER CONTROLLER GND C1- C2- C1+ C2+ ISOCOM Figure 1. Functional Diagram Detailed Description The MAX3250 is a 3.0V to 5.5V powered, 50V isolated EIA/TIA-232 and V.28/V.24 communications interface with high data-rate capabilities. The MAX3250 is a dual die part that operates with up to 50V difference between the RS-232 side and the logic side (ISOCOM to GND). This makes the device ideal for operation in noisy conditions with high common-mode voltages. This feature prevents damage to the device if RS-232 lines are inadvertently short-circuited to a +24V or 48V power bus. The MAX3250 typically draws 15mA of supply current when unloaded. Supply current drops to 20A when the device is placed in shutdown mode. 6 The MAX3250 has two receivers and two drivers and is guaranteed to operate at data rates up to 250kbps. The device features a FAULT open-drain output to signal an excessive isolated-side voltage condition on any of the RS-232 inputs. This output can drive an alarm LED or can be monitored by the processor to prevent operation under these conditions. The receiver outputs are high impedance in shutdown, allowing multiple interfaces (IrDA, RS-232, RS-485) to be connected to the same UART (Figure 1). The MAX3250 is a low-cost replacement for opto-isolated transceivers. Isolated Power Supply The MAX3250 drives a high-frequency square wave into C1 and a complementary square wave into C2. These _______________________________________________________________________________________ 50V Isolated, 3.0V to 5.5V, 250kbps, 2 TX/2 RX, RS-232 Transceiver AC waveforms are rectified on the isolated side of the dual die to power its internal circuitry (ISOV CC ). Capacitor C6 filters the output of the rectifier. See the Typical Operating Circuit. The power controller works in a dual power mode. Power is maximum when the isolated power supply is below its regulation point. Power is reduced when the isolated power supply is above its regulation point. RS-232 Receivers The receivers convert RS-232 signals to CMOS-logic output levels. The receivers' outputs are forced into a high-impedance state when the device is in shutdown. This allows a single UART to multiplex between different protocols. MAX3250 Low-Power Shutdown Mode Shutdown mode is obtained by driving SHDN low. In shutdown, the devices typically draw only 20A of supply current and no power is transferred across the isolation capacitors. The charge pumps are disabled, and the receiver outputs and transmitter outputs are high impedance. When exiting shutdown the charge pumps and transmitter outputs are fully operational in typically 500s (Figure 3). Connect SHDN to VCC if the shutdown mode is not used. Dual Charge-Pump Voltage Converter The RS-232 drivers are powered from a regulated dual charge pump that provides output voltages of +5.5V (doubling charge pump) and -5.5V (inverting charge pump) relative to ISOCOM over the 3.0V to 5.5V VCC range. The charge pumps are powered from ISOV CC and operate in a discontinuous mode. If the output voltages are less than 5.5V, the charge pumps are enabled. If the output voltages exceed 5.5V, the charge pumps are disabled. Each charge pump requires a flying capacitor (C3, C4) and a reservoir capacitor (C7, C8) to generate the V+ and V- supplies. Applications Information Power Isolation Capacitors The values for capacitors C1 and C2 are important for proper operation of the device. These capacitors should be 0.047F for 4.5V to 5.5V operation, and 0.47F for 3.0V to 3.6V operation. Smaller values result in insufficient supply voltage on the isolated side. Larger values are not allowed. Capacitor C9 provides an AC feedback path for proper controller operation. Connect C9 from ISOCOM to GND. The values for C1, C2, and C9 determine the maximum frequency and amplitude of the voltage difference between the local and isolated ground. Table 1 shows proper capacitance values. RS-232 Transmitters The transmitters are inverting level translators that convert TTL/CMOS-logic levels to 5.0V EIA/TIA-232-compliant levels. They guarantee a 250kbps data rate with worstcase loads of 3k in parallel with 1000pF to ISOCOM. In shutdown, the transmitters are disabled and the outputs are forced into a high-impedance state. When powered off or shut down, the outputs can be driven up to 12V relative to ISOCOM. The transmitter inputs do not have pullup resistors. All unused inputs should be connected to VCC or GND. TRANSMITTER OUTPUT VOLTAGE (V) 6 5 4 3 2 1 0 -1 -2 -3 -4 -5 -6 0 VCC = 3.0V VOUT+ SHDN 5V/div T1OUT T1 VOUT1+ VCC T2 VOUT2- 2V/div VOUTVCC = 3.3V 1 2 3 4 5 6 7 8 100s/div T2OUT LOAD CURRENT PER TRANSMITTER (mA) Figure 2. Transmitter Output Voltage vs. Load Current per Transmitter Figure 3. Transmitter Outputs when Exiting Shutdown or Powering Up 7 _______________________________________________________________________________________ 50V Isolated, 3.0V to 5.5V, 250kbps, 2 TX/2 RX, RS-232 Transceiver MAX3250 Table 1. Required Capacitor Values VCC (V) 3.0 to 3.6 4.5 to 5.5 C1, C2 (F) 0.47 0.047 C3 (F) 0.1 0.1 C4, C7, C8 (F) 0.47 0.47 C5, C6 (F) 1 1 C9 (nF) 10 10 To achieve full isolation capability, C1, C2, and C9 should be rated for 100V or higher operation and be X7R or X5R type or metalized film dielectric. Y5V and Z5U dielectrics should be avoided as their voltage and temperature coefficients make their power-transfer capabilities insufficient. Maximum Voltage Between ISOCOM and Logic GND High values of applied isolation voltage and frequency can cause ripple on ISOVCC, V+, V-, and in extreme cases on VCC. Therefore, it is recommended that the isolation-voltage and frequency be limited to the values shown in the Typical Operating Characteristics. Insert a 1k 1/4W resistor in series with any isolation test voltage when testing for maximum values of applied isolation voltage. Exceeding the maximum limits of voltage and frequency (see the Typical Operating Characteristics) could trigger a holding current in the internal ESD-protection device if the 80V isolation limit is exceeded. This resistor should not be used in normal application. Charge-Pump and Bypass Capacitors Capacitors C3-C8 should be X7R or X5R type dielectric. Their voltage rating needs to be 10V or higher. Layout Information Because the MAX3250 is intended for systems requiring 50V isolation, some consideration in component placement is necessary. A 20mil air gap should isolate the logic side and the isolated RS-232 side, across the N.C. pins (pin numbers 6, 7, 22, and 23) of the MAX3250. The only components that cross this air gap should be C1, C2, and C9, which should all have a minimum 100V rating. All capacitors should be located as close to the MAX3250 as possible. Transmitter Outputs when Exiting Shutdown Figure 3 shows two transmitter outputs when exiting shutdown mode. As they become active, the two transmitter outputs are shown going to opposite RS-232 levels (one transmitter input is high, the other is low). Each transmitter is loaded with 3k in parallel with 2500pF. The transmitter outputs display no ringing or undesirable transients as they come out of shutdown. Note that the transmitters are enabled only when the magnitude of V- exceeds approximately -3V. 8 _______________________________________________________________________________________ 50V Isolated, 3.0V to 5.5V, 250kbps, 2 TX/2 RX, RS-232 Transceiver Typical Operating Circuit VCC C5 1F VCC RIN1 TOUT1 FAULT SHDN MICRO TIN1 ROUT1 TIN2 ROUT2 C1+ C1C2+ C2GND C9 10nF ISOCOM RIN2 TOUT2 C4+ C4 0.47F C3 0.1F CABLE REMOTE MICRO REMOTE XCVR MAX3250 MAX3250 C4C3+ C3V+ VISOVCC C6 1F C1 0.47F C2 0.47F C8 0.47F C7 0.47F 50V GND OFFSET REMOTE GROUND Chip Information TRANSISTOR COUNT: 2094 PROCESS: BiCMOS _______________________________________________________________________________________ 9 50V Isolated, 3.0V to 5.5V, 250kbps, 2 TX/2 RX, RS-232 Transceiver MAX3250 Package Information (The package drawing(s) in this data sheet may not reflect the most current specifications. For the latest package outline information, go to www.maxim-ic.com/packages.) SSOP.EPS 2 1 INCHES DIM A A1 B C E H D E e H L MIN 0.068 0.002 0.010 MAX 0.078 0.008 0.015 MILLIMETERS MIN 1.73 0.05 0.25 MAX 1.99 0.21 0.38 D D D D D INCHES MIN 0.239 0.239 0.278 0.317 0.397 MAX 0.249 0.249 0.289 0.328 0.407 MILLIMETERS MIN 6.07 6.07 7.07 8.07 10.07 MAX 6.33 6.33 7.33 8.33 10.33 N 14L 16L 20L 24L 28L 0.20 0.09 0.004 0.008 SEE VARIATIONS 0.205 0.301 0.025 0 0.212 0.311 0.037 8 5.20 7.65 0.63 0 5.38 7.90 0.95 8 0.0256 BSC 0.65 BSC N A C B e D A1 L NOTES: 1. D&E DO NOT INCLUDE MOLD FLASH. 2. MOLD FLASH OR PROTRUSIONS NOT TO EXCEED .15 MM (.006"). 3. CONTROLLING DIMENSION: MILLIMETERS. 4. MEETS JEDEC MO150. 5. LEADS TO BE COPLANAR WITHIN 0.10 MM. PROPRIETARY INFORMATION TITLE: PACKAGE OUTLINE, SSOP, 5.3 MM APPROVAL DOCUMENT CONTROL NO. REV. 21-0056 1 1 C Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. 10 ____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 (c) 2003 Maxim Integrated Products Printed USA is a registered trademark of Maxim Integrated Products. |
Price & Availability of MAX3250
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |