![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
HIGH-SPEED 64K x 18 SYNCHRONOUS PIPELINED DUAL-PORT STATIC RAM Features x x IDT709389L x x x x True Dual-Ported memory cells which allow simultaneous access of the same memory location High-speed clock to data access - Commercial: 7.5/9/12ns (max.) Low-power operation - IDT709389L Active: 1.2W (typ.) Standby: 2.5mW (typ.) Flow-Through or Pipelined output mode on either Port via the FT/PIPE pins Counter enable and reset features Dual chip enables allow for depth expansion without additional logic x x x x x Full synchronous operation on both ports - 4ns setup to clock and 0ns hold on all control, data, and address inputs - Data input, address, and control registers - Fast 7.5ns clock to data out in the Pipelined output mode - Self-timed write allows fast cycle time - 12ns cycle time, 83MHz operation in Pipelined output mode Separate upper-byte and lower-byte controls for multiplexed bus and bus matching compatibility TTL- compatible, single 5V (10%) power supply Industrial temperature range (-40C to +85C) is available for selected speeds Available in a 100-pin Thin Quad Flatpack (TQFP) package Functional Block Diagram R/WL UBL CE0L R/WR UBR CE0R CE1L LBL OEL 1 0 0/1 1 0 0/1 CE1R LBR OER FT/PIPEL 0/1 1b 0b ba 1a 0a 0a 1a a b 0b 1b 0/1 FT/PIPER I/O9L-I/O17L I/O0L-I/O8L I/O Control I/O9R-I/O17R I/O Control I/O0R-I/O8R A15L A0L CLKL Counter/ Address Reg. MEMORY ARRAY Counter/ Address Reg. A15R A0R CLKR ADSL CNTENL CNTRSTL ADSR CNTENR CNTRSTR 4844 drw 01 JANUARY 2001 1 (c)2000 Integrated Device Technology, Inc. DSC-4844/3 IDT709389L High-Speed 64K x 18 Synchronous Pipelined Dual-Port Static RAM Industrial and Commercial Temperature Ranges Description The IDT709389 is a high-speed 64K x 18 bit synchronous DualPort RAM. The memory array utilizes Dual-Port memory cells to allow simultaneous access of any address from both ports. Registers on control, data, and address inputs provide minimal setup and hold times. The timing latitude provided by this approach allows systems to be designed with very short cycle times. With an input data register, the IDT709389 has been optimized for applications having unidirectional or bidirectional data flow in bursts. An automatic power down feature, controlled by CE0 and CE1, permits the on-chip circuitry of each port to enter a very low standby power mode. Fabricated using IDT's CMOS high-performance technology, these devices typically operate on only 1.2W of power. Pin Configurations(1,2,3) INDEX A9L A10L A11L A12L A13L A14L A15L LBL UBL CE0L CE1L CNTRSTL R/WL OEL Vcc FT/PIPEL I/O17L I/O16L GND I/O15L I/O14L I/O13L I/O12L I/O11L I/O10L 100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76 1 75 2 74 3 73 4 72 5 71 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 70 69 68 67 66 A8L A7L A6L A5L A4L A3L A2L A1L A0L CNTENL CLKL ADSL GND GND ADSR CLKR CNTENR A0R A1R A2R A3R A4R A5R A6R A7R 65 64 63 62 61 60 59 58 57 56 55 54 53 709389PF PN100-1(4) 100-Pin TQFP Top View(5) 52 51 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 A8R A9R A10R A11R A12R A13R A14R A15R LBR UBR CE0R CE1R CNTRSTR R/WR GND OER FT/PIPER I/O17R GND I/O16R I/O15R I/O14R I/O13R I/O12R I/O11R 4844 drw 02 NOTES: 1. All VCC pins must be connected to power supply. 2. All GND pins must be connected to ground. 3. Package body is approximately 14mm x 14mm x 1.4mm 4. This package code is used to reference the package diagram. 5. This text does not indicate orientation of the actual part-marking. I/O9L I/O8L Vcc I/O7L I/O6L I/O5L I/O4L I/O3L I/O2L GND I/O1L I/O0L GND I/O0R I/O1R I/O2R I/O3R I/O4R I/O5R I/O6R Vcc I/O7R I/O8R I/O9R I/O10R 2 6.42 IDT709389L High-Speed 64K x 18 Synchronous Pipelined Dual-Port Static RAM Industrial and Commercial Temperature Ranges Pin Names Left Port CE0L, CE1L R/WL OEL A0L - A15L I/O0L - I/O17L CLKL UBL LBL ADSL CNTENL CNTRSTL FT/PIPEL Right Port CE0R, CE1R R/WR OER A0R - A15R I/O0R - I/O17R CLKR UBR LBR ADSR CNTENR CNTRSTR FT/PIPER VCC GND Names Chip Enables Read/Write Enable Output Enable Address Data Input/Output Clock Upper Byte Select Lower Byte Select Address Strobe Counter Enable Counter Reset Flow-Through/Pipeline Power Ground 4844 tbl 01 Truth Table IRead/Write and Enable Control(1,2,3) OE X X X X X X L L L H CLK X CE0 H X L L L L L L L L CE1 X L H H H H H H H H UB X X H L H L L H L L LB X X H H L L H L L L R/W X X X L L L H H H X Upper Byte I/O9-17 High-Z High-Z High-Z DATAIN High-Z DATAIN DATAOUT High-Z DATAOUT High-Z Lower Byte I/O0-8 High-Z High-Z High-Z High-Z DATAIN DATAIN High-Z DATAOUT DATAOUT High-Z Mode Deselected--Power Down Deselected--Power Down Both Bytes Deselected Write to Upper Byte Only Write to Lower Byte Only Write to Both Bytes Read Upper Byte Only Read Lower Byte Only Read Both Bytes Outputs Disabled 4844 tbl 02 NOTES: 1. "H" = VIH, "L" = VIL, "X" = Don't Care. 2. ADS, CNTEN, CNTRST = X. 3. OE is an asynchronous input signal. 6.42 3 IDT709389L High-Speed 64K x 18 Synchronous Pipelined Dual-Port Static RAM Industrial and Commercial Temperature Ranges Truth Table IIAddress Counter Control(1,2,6) Address X An An X Previous Address X X Ap Ap Addr Used 0 An Ap Ap + 1 CLK ADS X L H H (4) CNTEN X X H L (5) CNTRST L H H H I/O(3) DI/O(0) DI/O(n) DI/O(p) DI/O(p+1) Mode Counter Reset to Address 0 External Address Utilized External Address Blocked--Counter Disabled (Ap reused) Counter Enable--Internal Address Generation 4844 tbl 03 NOTES: 1. "H" = VIH, "L" = VIL, "X" = Don't Care. 2. CE0, LB, UB, and OE = VIL; CE1 and R/W = VIH. 3. Outputs configured in Flow-Through Output mode: if outputs are in Pipelined mode the data out will be delayed by one cycle. 4. ADS is independent of all other signals including CE0, CE1, UB and LB. 5. The address counter advances if CNTEN = VIL on the rising edge of CLK, regardless of all other signals including CE0, CE1, UB and LB. 6. While an external address is being loaded (ADS = VIL), R/W = VIH is recommended to ensure data is not written arbitrarily. Recommended Operating Recommended DC Operating Temperature and Supply Voltage(1) Conditions Grade Commercial Industrial Ambient Temperature(2) 0OC to +70OC -40OC to +85OC GND 0V 0V Vcc 5.0V + 10% 5.0V + 10% 4844 tbl 04 Symbol VCC GND VIH VIL Parameter Supply Voltage Ground Input High Voltage Input Low Voltage Min. 4.5 0 2.2 -0.5(2) Typ. 5.0 0 ____ Max. 5.5 0 6.0(1) 0.8 Unit V V V V 4844 tbl 05 NOTES: 1. Industrial temperature: for specific speeds, packages and powers contact your sales office. 2. This is the parameter TA. This is the "instant on" case temperature. ____ NOTES: 1. VTERM must not exceed Vcc + 10%. 2. VIL > -1.5V for pulse width less than 10ns. Absolute Maximum Ratings(1) Symbol VTERM (2) Capacitance(1) Unit V Symbol CIN COUT (3) Rating Terminal Voltage with Respect to GND Temperature Under Bias Storage Temperature DC Output Current Commercial & Industrial -0.5 to +7.0 (TA = +25C, f = 1.0MHz) Parameter Input Capacitance Output Capacitance Conditions(2) VIN = 3dV VOUT = 3dV Max. 9 10 Unit pF pF 4844 tbl 07 TBIAS TSTG IOUT -55 to +125 -65 to +150 50 o C C o mA 4844 tbl 06 NOTES: 1. These parameters are determined by device characterization, but are not production tested. 2. 3dV references the interpolated capacitance when the input and output switch from 0V to 3V or from 3V to 0V. 3. COUT also references CI/O. NOTES: 1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. 2. VTERM must not exceed Vcc + 10% for more than 25% of the cycle time or 10ns maximum, and is limited to < 20mA for the period of VTERM > Vcc + 10%. 4 6.42 IDT709389L High-Speed 64K x 18 Synchronous Pipelined Dual-Port Static RAM Industrial and Commercial Temperature Ranges DC Electrical Characteristics Over the Operating Temperature Supply Voltage Range (VCC = 5.0V 10%) 709389L Symbol |ILI| |ILO| VOL VOH Parameter Input Leakage Current(1) Output Leakage Current Output Low Voltage Output High Voltage Test Conditions VCC = 5.5V, VIN = 0V to VCC CE0 = VIH or CE1 = VIL, VOUT = 0V to VCC IOL = +4mA IOH = -4mA Min. ___ Max. 5 5 0.4 ___ Unit A A V V 4844 tbl 08 ___ ___ 2.4 NOTE: 1. At Vcc < 2.0V input leakages are undefined. DC Electrical Characteristics Over the Operating Temperature and Supply Voltage Range(3,6) (VCC = 5V 10%) 709389L7 Com'l Only Symbol ICC Parameter Dynamic Operating Current (Both Ports Active) Standby Current (Both Ports - TTL Level Inputs) Standby Current (One Port - TTL Level Inputs) Full Standby Current (Both Ports CMOS Level Inputs) Full Standby Current (One Port CMOS Level Inputs) Test Condition CEL and CER= VIL Outputs Disabled f = fMAX(1) CEL = CER = VIH f = fMAX(1) CE"A" = VIL and CE"B" = VIH(3) Active Port Outputs Disabled, f=fMAX(1) Both Ports CER and CEL > VCC - 0.2V VIN > VCC - 0.2V or VIN < 0.2V, f = 0(2) CE"A" < 0.2V and CE"B" > VCC - 0.2V(5) VIN > VCC - 0.2V or VIN < 0.2V, Active Port Outp uts Disabled, f = fMAX(1) Version COM'L IND COM'L IND COM'L IND COM'L IND COM'L IND L L L L L L L L L L Typ.(4) 275 ____ 709389L9 Com'l Only Typ.(4) 250 ____ 709389L12 Com'l Only Typ.(4) 230 ____ Max. 465 ____ Max. 400 ____ Max. 355 ____ Unit mA ISB1 95 ____ 150 ____ 80 ____ 135 ____ 70 ____ 110 ____ mA ISB2 200 ____ 295 ____ 175 ____ 275 ____ 150 ____ 240 ____ mA ISB3 0.5 ____ 3 ____ 0.5 ____ 3 ____ 0.5 ____ 3 ____ mA ISB4 190 ____ 290 ____ 170 ____ 270 ____ 140 ____ 225 ____ mA NOTES: 1. At f = fMAX, address and control lines (except Output Enable) are cycling at the maximum frequency clock cycle of 1/tCYC, using "AC TEST CONDITIONS" at input levels of GND to 3V. 2. f = 0 means no address, clock, or control lines change. Applies only to input at CMOS level standby. 3. Port "A" may be either left or right port. Port "B" is the opposite from port "A". 4. Vcc = 5V, TA = 25C for Typ, and are not production tested. ICC DC(f=0) = 150mA (Typ). 5. CEX = VIL means CE0X = VIL and CE1X = VIH CEX = VIH means CE0X = VIH or CE1X = VIL CEX < 0.2V means CE0X < 0.2V and CE1X > VCC - 0.2V CEX > VCC - 0.2V means CE0X > VCC - 0.2V or CE1X < 0.2V "X" represents "L" for left port or "R" for right port. 6. Industrial temperature: for specific speeds, packages and powers contact your sales office. 4844 tbl 09 6.42 5 IDT709389L High-Speed 64K x 18 Synchronous Pipelined Dual-Port Static RAM Industrial and Commercial Temperature Ranges AC Test Conditions Input Pulse Levels Input Rise/Fall Times Input Timing Reference Levels Output Reference Levels Output Load GND to 3.0V 3ns Max. 1.5V 1.5V Figures 1,2 and 3 4844 tbl 10 5V 893 DATAOUT 347 30pF DATAOUT 347 5V 893 5pF* 4844 drw 04 4844 drw 05 Figure 1. AC Output Test load. Figure 2. Output Test Load (For tCKLZ, tCKHZ, tOLZ, and tOHZ). *Including scope and jig. 8 7 6 5 tCD1, tCD2 (Typical, ns) 4 3 2 1 0 -1 - 10pF is the I/O capacitance of this device, and 30pF is the AC Test Load Capacitance 20 40 60 80 100 120 140 160 180 200 Capacitance (pF) 4844 drw 06 Figure 3. Typical Output Derating (Lumped Capacitive Load). 6 6.42 IDT709389L High-Speed 64K x 18 Synchronous Pipelined Dual-Port Static RAM Industrial and Commercial Temperature Ranges AC Electrical Characteristics Over the Operating Temperature Range (Read and Write Cycle Timing)(3,4) (VCC = 5V 10%, TA = 0C to +70C) 709389L7 Com'l Only Symbol tCYC1 tCYC2 tCH1 tCL1 tCH2 tCL2 tR tF tSA tHA tSC tHC tSB tHB tSW tHW tSD tHD tSAD tHAD tSCN tHCN tSRST tHRST tOE tOLZ tOHZ tCD1 tCD2 tDC tCKHZ tCKLZ Clock Cycle Time (Flow-Through)(2) Clock Cycle Time (Pipelined) (2) (2) 709389L9 Com'l Only Min. 25 15 12 12 6 6 ____ 709389L12 Com'l Only Min. 30 20 12 12 8 8 ____ Parameter Min. 22 12 7.5 7.5 5 5 ____ Max. ____ ____ Max. ____ ____ Max. ____ ____ Unit ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns Clock High Time (Flow-Through) ____ ____ ____ ____ ____ ____ ____ ____ ____ Clock Low Time (Flow-Through)(2) Clock High Time (Pipelined) Clock Low Time (Pipelined) Clock Rise Time Clock Fall Time Address Setup Time Address Hold Time Chip Enable Setup Time Chip Enable Hold Time Byte Enable Setup Time Byte Enable Hold Time R/W Setup Time R/W Hold Time Input Data Setup Time Input Data Hold Time ADS Setup Time ADS Hold Time CNTEN Setup Time CNTEN Hold Time CNTRST Setup Time CNTRST Hold Time Output Enable to Data Valid Output Enable to Output Low-Z (1) (1) (2) (2) ____ ____ ____ 3 3 ____ ____ 3 3 ____ ____ 3 3 ____ ____ ____ ____ ____ 4 0 4 0 4 0 4 0 4 0 4 0 4 0 4 0 ____ 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 ____ 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ 9 ____ 12 ____ 12 ____ 2 1 ____ ____ 2 1 ____ ____ 2 1 ____ ____ Output Enable to Output High-Z 7 18 7.5 ____ 7 20 9 ____ 7 25 12 ____ Clock to Data Valid (Flow-Through)(2) Clock to Data Valid (Pipelined)(2) Data Output Hold After Clock High Clock High to Output High-Z(1) Clock High to Output Low-Z (1) 2 2 2 2 2 2 2 2 2 9 ____ 9 ____ 9 ____ Port-to-Port Delay tCWDD tCCS Write Port Clock High to Read Data Delay Clock-to-Clock Setup Time ____ 28 10 ____ 35 15 ____ 40 15 ns ns ____ ____ ____ 4844 tbl 11 NOTES: 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). This parameter is guaranteed by device characterization, but is not production tested. 2. The Pipelined output parameters (tCYC2, tCD2) to either the Left or Right ports when FT/PIPE = VIH. Flow-Through parameters (tCYC1, tCD1) apply when FT/PIPE = VIL for that port. 3. All input signals are synchronous with respect to the clock except for the asynchronous Output Enable (OE), FT/PIPER and FT/PIPEL. 4. Industrial temperature: for specific speeds, packages and powers contact your sales office. 6.42 7 IDT709389L High-Speed 64K x 18 Synchronous Pipelined Dual-Port Static RAM Industrial and Commercial Temperature Ranges Timing Waveform of Read Cycle for Flow-Through Output (FT/PIPE"X" = VIL)(3,7) tCYC1 tCH1 CLK CE0 tSC CE1 tSB UB, LB R/W tHB tSB tHB tHC tSC (4) tCL1 tHC tSW tSA tHW tHA An + 1 tCD1 tDC Qn tCKLZ (1) ADDRESS (5) An An + 2 An + 3 tCKHZ (1) DATAOUT Qn + 1 tOHZ (1) Qn + 2 tOLZ (1) tDC OE (2) tOE 4844 drw 07 Timing Waveform of Read Cycle for Pipelined Operation (FT/PIPE"X" = VIH)(3,7) tCYC2 tCH2 CLK CE0 tSC CE1 UB, LB tSB tHB tSB (6) tCL2 tHC tSC (4) tHC tHB R/W tSW tSA tHW tHA An + 1 (1 Latency) An + 2 tDC Qn tCKLZ (1) ADDRESS (5) An An + 3 tCD2 DATAOUT Qn + 1 tOHZ (1) Qn + 2 tOLZ (1) (6) OE (2) tOE NOTES: 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 2. OE is asynchronously controlled; all other inputs are synchronous to the rising clock edge. 3. ADS = VIL, CNTEN and CNTRST = VIH. 4. The output is disabled (High-Impedance state) by CE0 = VIH, CE1 = VIL, UB = VIH, or LB = VIH following the next rising edge of the clock. Refer to Truth Table 1. 5. Addresses do not have to be accessed sequentially since ADS = VIL constantly loads the address on the rising edge of the CLK; numbers are for reference use only. 6. If UB or LB was HIGH, then the Upper Byte and/or Lower Byte of DATAOUT for Qn + 2 would be disabled (High-Impedance state). 7. "X" here denotes Left or Right port. The diagram is with respect to that port. 4844 drw 08 8 6.42 IDT709389L High-Speed 64K x 18 Synchronous Pipelined Dual-Port Static RAM Industrial and Commercial Temperature Ranges Timing Waveform of a Bank Select Pipelined Read(1,2) tCH2 CLK tSA ADDRESS(B1) tHA A0 tSC tHC tSC tCD2 DATAOUT(B1) tSA ADDRESS(B2) tHA A0 A1 A2 A3 A4 A5 A6 Q0 tDC tHC tCD2 tCKHZ Q1 tDC (3) tCYC2 tCL2 A1 A2 A3 A4 A5 A6 CE0(B1) tCD2 Q3 tCKLZ (3) tCKHZ (3) tSC CE0(B2) tSC tHC tHC tCD2 DATAOUT(B2) tCKLZ (3) tCKHZ (3) Q2 tCD2 tCKLZ (3) 4844 drw 09 Q4 Timing Waveform of Write with Port-to-Port Flow-Through Read(4,5,7) CLK "A" tSW R/W "A" tSA ADDRESS "A" tHA NO MATCH tHW MATCH tSD DATAIN "A" tHD VALID tCCS CLK "B" (6) tCD1 R/W "B" tSW tSA ADDRESS "B" tHW tHA NO MATCH MATCH tCWDD DATAOUT "B" tDC (6) tCD1 VALID VALID tDC 4844 drw 10 NOTES: 1. B1 Represents Bank #1; B2 Represents Bank #2. Each Bank consists of one IDT709389 for this waveform, and are setup for depth expansion in this example. ADDRESS(B1) = ADDRESS(B2) in this situation. 2. UB, LB, OE, and ADS = VIL; CE1(B1), CE1(B2), R/W, CNTEN, and CNTRST = VIH. 3. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 4. CE0, UB, LB, and ADS = VIL; CE1, CNTEN, and CNTRST = VIH. 5. OE = VIL for the Right Port, which is being read from. OE = VIH for the Left Port, which is being written to. 6. If tCCS < maximum specified, then data from right port READ is not valid until the maximum specified for tCWDD. If tCCS > maximum specified, then data from right port READ is not valid until tCCS + tCD1. tCWDD does not apply in this case. 7. All timing is the same for both Left and Right ports. Port "A" may be either Left or Right port. Port "B" is the opposite from Port "A". 6.42 9 IDT709389L High-Speed 64K x 18 Synchronous Pipelined Dual-Port Static RAM Industrial and Commercial Temperature Ranges Timing Waveform of Pipelined Read-to-Write-to-Read (OE = VIL)(3) tCYC2 tCH2 tCL2 CLK CE0 tSC tHC CE1 tSB UB, LB tSW tHW R/W tSW tHW tHB ADDRESS (4) An tSA tHA An +1 An + 2 An + 2 tSD tHD Dn + 2 An + 3 An + 4 DATAIN (2) tCD2 Qn READ tCKHZ (1) tCKLZ (1) tCD2 Qn + 3 DATAOUT NOP (5) WRITE READ 4844 drw 11 . Timing Waveforn of Pipelined Read-to-Write-to-Read (OE Controlled)(3) tCYC2 tCH2 CLK CE0 tSC CE1 tSB UB, LB tSW tHW R/W tSW tHW tHB tHC tCL2 ADDRESS (4) An tSA tHA An +1 An + 2 tSD tHD An + 3 An + 4 An + 5 DATAIN (2) tCD2 Qn tOHZ(1) Dn + 2 Dn + 3 tCKLZ(1) tCD2 Qn + 4 DATAOUT OE READ WRITE READ . 4844 drw 12 NOTES: 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 2. Output state (High, Low, or High-impedance) is determined by the previous cycle control signals. 3. CE0, UB, LB, and ADS = VIL; CE1, CNTEN, and CNTRST = VIH. "NOP" is "No Operation". 4. Addresses do not have to be accessed sequentially since ADS = VIL constantly loads the address on the rising edge of the CLK; numbers are for reference use only. 5. "NOP" is "No Operation." Data in memory at the selected address may be corrupted and should be re-written to guarantee data integrity. 10 6.42 IDT709389L High-Speed 64K x 18 Synchronous Pipelined Dual-Port Static RAM Industrial and Commercial Temperature Ranges Timing Waveform of Flow-Through Read-to-Write-to-Read (OE = VIL)(3) tCH1 CLK tCYC1 tCL1 CE0 tSC CE1 tSB UB, LB tSW tHW R/W tSW tHW tHB tHC ADDRESS (4) tSA DATAIN (2) An tHA An +1 An + 2 An + 2 tSD tHD Dn + 2 An + 3 An + 4 tCD1 Qn tDC READ tCD1 Qn + 1 tCKHZ (5) NOP (1) tCD1 Qn + 3 tCKLZ WRITE (1) tCD1 DATAOUT tDC READ 4844 drw 13 Timing Waveform of Flow-Through Read-to-Write-to-Read (OE Controlled)(3) tCYC1 tCH1 tCL1 CLK CE0 tSC CE1 tSB UB, LB tSW tHW R/W ADDRESS (4) tHC tHB tSW tHW An tHA An +1 An + 2 tSD tHD Dn + 2 (2) An + 3 An + 4 An + 5 tSA DATAIN Dn + 3 tCD1 Qn tDC tOE tCD1 (1) tCD1 Qn + 4 tDC DATAOUT tOHZ OE READ (1) tCKLZ WRITE READ 4844 drw 14 NOTES: 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 2. Output state (High, Low, or High-impedance is determined by the previous cycle control signals. 3. CE0, UB, LB, and ADS = VIL; CE1, CNTEN, and CNTRST = VIH. "NOP" is "No Operation". 4. Addresses do not have to be accessed sequentially since ADS = VIL constantly loads the address on the rising edge of the CLK; numbers are for reference use only. 5. "NOP" is "No Operation." Data in memory at the selected address may be corrupted and should be re-written to guarantee data integrity. 6.42 11 IDT709389L High-Speed 64K x 18 Synchronous Pipelined Dual-Port Static RAM Industrial and Commercial Temperature Ranges Timing Waveform of Pipelined Read with Address Counter Advance(1) tCH2 CLK tSA ADDRESS tHA tCYC2 tCL2 An tSAD tHAD ADS tSAD tHAD CNTEN tCD2 DATAOUT Qx - 1(2) Qx tDC READ EXTERNAL ADDRESS READ WITH COUNTER Qn tSCN tHCN Qn + 1 Qn + 2(2) Qn + 3 COUNTER HOLD READ WITH COUNTER 4844 drw 15 Timing Waveform of Flow-Through Read with Address Counter Advance(1) tCH1 CLK tSA ADDRESS tHA tCYC1 tCL1 An tSAD tHAD ADS tSAD tHAD tSCN tHCN CNTEN tCD1 DATAOUT Qx(2) tDC READ EXTERNAL ADDRESS READ WITH COUNTER COUNTER HOLD READ WITH COUNTER 4844 drw 16 Qn Qn + 1 Qn + 2 Qn + 3(2) Qn + 4 NOTES: 1. CE0, OE, UB, and LB = VIL; CE1, R/W, and CNTRST = VIH. 2. If there is no address change via ADS = VIL (loading a new address) or CNTEN = VIL (advancing the address), i.e. ADS = VIH and CNTEN = VIH, then the data output remains constant for subsequent clocks. 12 6.42 IDT709389L High-Speed 64K x 18 Synchronous Pipelined Dual-Port Static RAM Industrial and Commercial Temperature Ranges Timing Waveform of Write with Address Counter Advance (Flow-Through or Pipelined Outputs)(1) tCH2 CLK tSA ADDRESS tHA An tCYC2 tCL2 INTERNAL(3) ADDRESS tSAD tHAD ADS An(7) An + 1 An + 2 An + 3 An + 4 CNTEN tSD tHD DATAIN Dn WRITE EXTERNAL ADDRESS Dn + 1 Dn + 1 Dn + 2 Dn + 3 Dn + 4 WRITE WRITE WITH COUNTER COUNTER HOLD WRITE WITH COUNTER 4844 drw 17 Timing Waveform of Counter Reset (Pipelined Outputs)(2) tCH2 CLK tSA tHA ADDRESS(4) INTERNAL(3) ADDRESS Ax(6) tSW tHW R/W ADS CNTEN tSRST tHRST CNTRST DATAIN DATAOUT(5) COUNTER(6) RESET WRITE ADDRESS 0 READ ADDRESS 0 READ ADDRESS 1 tSD tHD D0 Q0 READ ADDRESS n Q1 READ ADDRESS n+1 4844 drw 18 tCYC2 tCL2 An An + 1 An + 2 0 1 An An + 1 Qn . NOTES: 1. CE0, UB, LB, and R/W = VIL; CE1 and CNTRST = VIH. 2. CE0, UB, LB = VIL; CE1 = VIH. 3. The "Internal Address" is equal to the "External Address" when ADS = VIL and equals the counter output when ADS = VIH. 4. Addresses do not have to be accessed sequentially since ADS = VIL constantly loads the address on the rising edge of the CLK; numbers are for reference use only. 5. Output state (High, Low, or High-impedance) is determined by the previous cycle control signals. 6. No dead cycle exists during counter reset. A READ or WRITE cycle may be coincidental with the counter reset cycle. 7. CNTEN = VIL advances Internal Address from `An' to `An +1'. The transition shown indicates the time required for the counter to advance. The `An +1' Address is written to during this cycle. 6.42 13 IDT709389L High-Speed 64K x 18 Synchronous Pipelined Dual-Port Static RAM Industrial and Commercial Temperature Ranges A Functional Description The IDT709389 provides a true synchronous Dual-Port Static RAM interface. Registered inputs provide minimal set-up and hold times on address, data, and all critical control inputs. All internal registers are clocked on the rising edge of the clock signal, however, the self-timed internal write pulse is independent of the LOW to HIGH transition of the clock signal. An asynchronous output enable is provided to ease asynchronous bus interfacing. Counter enable inputs are also provided to stall the operation of the address counters for fast interleaved memory applications. CE0 = VIH or CE1 = VIL for one clock cycle will power down the internal circuitry to reduce static power consumption. Multiple chip enables allow easier banking of multiple IDT709389's for depth expansion configurations. When the Pipelined output mode is enabled, two cycles are required with CE0 = VIL and CE1 = VIH to reactivate the outputs. Depth and Width Expansion The IDT709389 features dual chip enables (refer to Truth Table I) in order to facilitate rapid and simple depth expansion with no requirements for external logic. Figure 4 illustrates how to control the various chip enables in order to expand two devices in depth. The 709389 can also be used in applications requiring expanded width, as indicated in Figure 4. Since the banks are allocated at the discretion of the user, the external controller can be set up to drive the input signals for the various devices as required to allow for 36-bit or wider applications. A16 IDT709389 CE0 CE1 VCC IDT709389 CE0 CE1 VCC Control Inputs Control Inputs IDT709389 CE1 CE0 IDT709389 CE1 CE0 CNTRST CLK ADS CNTEN R/W UB, LB OE Control Inputs Control Inputs 4844 drw 19 Figure 4. Depth and Width Expansion with IDT709389 14 6.42 IDT709389L High-Speed 64K x 18 Synchronous Pipelined Dual-Port Static RAM Industrial and Commercial Temperature Ranges Ordering Information IDT XXXXX Device Type A Power 99 Speed A Package A Process/ Temperature Range Blank I(1) Commercial (0C to +70C) Industrial (-40C to +85C) PF 100-pin TQFP (PN100-1) 7 9 12 L Commercial Only Commercial Only Commercial Only Low Power Speed in nanoseconds 709389 1152K (64K x 18-Bit) Synchronous Dual-Port RAM 4844 drw 20 NOTE: 1. Industrial temperature range is available. For specific speeds, packages and powers contact your sales office. Datasheet Document History 9/30/99: 11/10/99: 12/22/99: 1/10/01: Initial Public Release Replaced IDT logo Page 1 Added missing diamond Page 4 Changed information in Truth Table II Increased storage temperature parameter Clarified TA parameter Page 5 DC Electrical parameters-changed wording from "open" to "disabled" Changed 200mV to 0mV in notes Removed Preliminary status CORPORATE HEADQUARTERS 2975 Stender Way Santa Clara, CA 95054 for SALES: 800-345-7015 or 408-727-611 6 fax: 408-492-8674 www.idt.com 6.42 15 for Tech Support: 831-754-4613 DualPortHelp@idt.com The IDT logo is a registered trademark of Integrated Device Technology, Inc. |
Price & Availability of IDT709389L
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |