![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Voltage Transducer AV100 Series For the electronic measurement of voltages : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high voltage) and the secondary circuit (electronic circuit). VPN = 50...1500 V Electrical data Primary nominal R.m.s or DC voltage Primary Voltage R.m.s. voltage for AC Type 1) measuring range isolation test (50 Hz/1min) VPN (V) VPmax (V) Vd (kV) 50 75 3.3 AV 100-50 125 187.5 3.3 AV 100-125 150 225 3.3 AV 100-150 250 375 3.3 AV 100-250 500 750 3.3 AV 100-500 750 1125 4.3 AV 100-750 1000 1500 5.5 AV 100-1000 1500 2250 6.5 AV 100-1500 Not measurable overload 2 x VPmax (1s/h) VDC Measuring resistance RM min RM max @ VC=11.4V 0 47 @ VC=22.8V 0 184 Secondary nominal r.m.s. current 50 mA Supply voltage ( 5 %) DC 12 .. 24 V Current consumption 50+IS mA Max Common mode voltage U HT+ + U HT- 4.2 k VDC and UHT+ - U HT- VPMAX R.m.s. voltage for partial discharge 1.1 2) kV extinction @ 10pC 2.2 3) kV Features * Insulated plastic case recognized according to UL 94-V0. * Included primary resistor Advantages * * * * * * * Low power Excellent accuracy Very good linearity Low thermal drift Low response time High bandwidth High immunity to external interference * Low disturbance in common mode. VP RM ISN VC Ic Ve Applications * AC variable speed drives and servo motor drives Accuracy - Dynamic performance data XG XG XG Overall Accuracy @ VPN , TA = + 25C Overall Accuracy @ VPN , TA = - 25 .. + 70C Overall Accuracy @ VPN , TA = - 40 .. + 85C Linearity @ TA = 25C Offset current @ VP = 0, TA = 25C Response time @ 10 % of VPmax Frequency bandwidth (- 3 dB) 0.7 % 1.5 % 1.7 % < 0.1 % 0.15 mA Between 10 and 13 s DC .. 13 kHz L IO tr f * Static converters for DC motor drives * Battery supplied applications * Uninterruptible Power Supplies (UPS) * Power supplies for welding applications . General data TA TS m Ambient operating temperature Ambient storage temperature Mass Standards - 40 .. + 85 - 50 .. + 90 375 EN 50155 EN 50124-1 NFF16101/2 C C g Notes : 1) Between primary and secondary 2) For models AV 100-50 to 750 3) For models AV 100-1000 & AV 100-1500 030523/4 LEM Components Dimensions AV100 Series (in mm. 1 mm = 0.0394 inch) Front view Left view HT+ HT+ M - Secondary terminals Terminal + : Supply voltage +12 .. 24 V Terminal M : Measure Terminal - : Supply voltage - 12 .. 24V Connection AV100 AV100 TOP view Mechanical characteristics * General tolerance * Fastening 1 mm 2 holes 6.5 mm Distance between holes axes : 124mm * Fastening & connection of primary 2 x M5 * Fastening & connection of secondary 3 x M5 or 3 Faston 6.35 x 0.8mm Output connections must be made with screened cables * Fastening torque: 2.2 Nm Remarks * IS is positive when VP is applied on terminal +HT. * This is a standard model. For different versions, please contact us. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. |
Price & Availability of AV100-500
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |