![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
VDE HIGH ELECTRICAL & MECHANICAL NOISE IMMUNITY RELAY 10 .394 JQ RELAYS 20 .787 FEATURES * High electrical noise immunity * High switching capacity in a compact package * High sensitivity: 200 mW (1a), 400 mW (1c) * High surge voltage: 8,000 V between contacts and coil * UL, CSA, VDE, TUV, SEMKO approved * Class B coil insulation type available mm inch 15.6 .614 SPECIFICATIONS Contact Arrangement Standard type High capacity type 1 Form A, 1 Form C 100 m Silver alloy 5 A 125 V AC 10 A 125 V AC 2 A 250 V AC 5 A 250 V AC 5 A 30 V DC 5 A 30 V DC 5 A 125 V AC 10 A 125 V AC 2 A 250 V AC 5 A 250 V AC 3 A 30 V AC 5 A 30 V DC 2 A 125 V AC 3 A 125 V AC 1 A 250 V AC 2 A 250 V AC 1 A 30 V DC 1 A 30 V DC Characteristics Max. operating speed Initial insulation resistance*1 Initial Between open contacts breakdown voltage*2 Between contacts and coil Surge voltage between contact and coil*3 Operate time*4 (at nominal voltage) Release time*4 (at nominal voltage)(without diode) Temperature rise*5 Functional*6 Shock resistance Destructive*7 Vibration resistance Functional*8 Destructive 20 cpm Min. 1,000 M at 500 V DC 1a: 1,000 Vrms for 1 min. 1c: 750 Vrms for 1 min. 4,000 Vrms for 1 min. 8,000 V Approx. 5 ms Approx. 2 ms Max. 45C Min. 294 m/s2 {30 G} Min. 980 m/s2 {100 G} 98 m/s2 {10 G}, 10 to 55 Hz at double amplitude of 1.6 mm 117.6 m/s2 {12 G}, 10 to 55 Hz at double amplitude of 2.0 mm -40C to +85C -40F to +185F 5 to 85% R.H. Approx. 7 g .25 oz Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material 1a Nominal switching capacity N.O. 1c N.C. Rating (resistive) Max. switching power 1a 625 VA, 150 W 1,250 VA, 150 W N.O. 625 VA, 90 W 1,250 V AC, 150 W 1c N.C. 250 VA, 30 W 500 V AC, 30 W Max. switching voltage 250 V AC, 110 V DC (0.3A) Max. switching current N.O.: 5 A N.C.: 2 A N.O.: 10 A N.C.: 3 A Expected mechanical life 107 (at 180 cpm)(min. operations) Conditions for operation, Ambient transport and storage*9 temp.*10 (Not freezing and condensHumidity ing at low temperature) Expected electrical life (min. operations) Type 1a Switching capacity 5 A 125 V AC 3 A 125 V AC 2 A 250 V AC 5 A 30 V DC 5 A 125 V AC 2 A 250 V AC 3 A 30 V DC 2 A 125 V AC 1 A 250 V AC 1 A 30 V DC 10 A 125 V AC 5 A 250 V AC 5 A 30 V DC 10 A 125 V AC 5 A 250 V AC 5 A 30 V DC 3 A 125 V AC 2 A 250 V AC 1 A 30 V DC No. of operations 5x104 2x105 2x105 105 5x104 2x105 105 2x105 2x105 105 5x104 5x104 105 5x104 5x104 105 2x105 2x105 105 Unit weight Remarks * *1 *2 *3 *4 *5 Specifications will vary with foreign standards certification ratings. Measurement at same location as "Initial breakdown voltage" section Detection current: 10 mA Wave is standard shock voltage of 1.2 x 50s according to JEC-212-1981 Excluding contact bounce time Measured conditions Resistive, nominal voltage applied to the coil. Contact carrying current: 5 A, at 70C 158F Resistive, nominal voltage applied to the coil. Contact carrying current: 10 A, at 70C 158F Standard type 1c N.O. Standard type High capacity type N.C. *6 *7 *8 *9 *10 1a High capacity type 1c N.C. N.O. Half-wave pulse of sine wave: 11ms; detection time: 10s Half-wave pulse of sine wave: 6ms Detection time: 10s Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24). When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1C 33.8F with 20C 68F as a reference) and use a coil impressed voltage that is within the maximum allowable voltage range. Coil (at 20C 68F) Nominal operating power 1a: 200 mW 1c: 400 mW 71 JQ TYPICAL APPLICATIONS * Air conditioners * Refrigerators * Microwave ovens * Heaters ORDERING INFORMATION Ex. Contact arrangement 1a: 1 Form A 1: 1 Form C JQ 1a P B 12 V Contact capacity Nil: Standard P: High capacity Coil insulation class Nil: Class E coil insulation B: Class B coil insulation Coil voltage (DC) 5, 6, 9, 12, 18, 24, 48* V UL/CSA, VDE, SEMKO approved type is standard. * Available only for 1 Form C type TYPES AND COIL DATA at 20C 68F Part No. JQ1a-5V JQ1a-6V JQ1a-9V JQ1A-12V JQ1a-18V JQ1a-24V JQ1aP-5V JQ1aP-6V JQ1aP-9V JQ1aP-12V JQ1aP-18V JQ1aP-24V JQ1-5V JQ1-6V JQ1-9V JQ1-12V JQ1-18V JQ1-24V JQ1-48V JQ1P-5V JQ1P-6V JQ1P-9V JQ1P-12V JQ1P-18V JQ1P-24V JQ1P-48V Nominal voltage, V DC 5 6 9 12 18 24 5 6 9 12 18 24 5 6 9 12 18 24 48 5 6 9 12 18 24 48 Pick-up voltage, V DC (min.) 3.75 4.5 6.75 9 13.5 18 4 4.8 7.2 9.6 14.4 19.2 3.75 4.5 6.75 9 13.5 18 36 4 4.8 7.2 9.6 14.4 19.2 38.4 Drop-out voltage, V DC (min.) 0.25 0.3 0.45 0.6 0.9 1.2 0.25 0.3 0.45 0.6 0.9 1.2 0.25 0.3 0.45 0.6 0.9 1.2 2.4 0.25 0.3 0.45 0.6 0.9 1.2 2.4 Nominal operating current, mA 40 33.3 22.2 16.7 11.1 8.3 40 33.3 22.2 16.7 11.1 8.3 80 66.7 44.4 33.3 22.2 16.7 8.3 80 66.7 44.4 33.3 22.2 16.7 8.3 Nominal operating power, mW Coil resistance, (10%) 125 180 405 720 1,620 2,880 125 180 405 720 1,620 2,880 62.5 90 202.5 360 810 1,440 5,760 62.5 90 202.5 360 810 1,440 5,760 Max. allowable voltage, V DC Standard type 200 180% of nominal voltage (at 20C 68F) 1 Form A High capacity type 200 130% of nominal voltage (at 85C 185F) Standard type 400 150% of nominal voltage (at 20C 68F) 1 Form C High capacity type 400 110% of nominal voltage (at 85C 185F) 72 JQ DIMENSIONS 1 Form A 10 .394 20 .787 mm inch 1 Form A Schematic (Bottom view) 1 Form C COM N.O. Coil N.C. COM N.O. 15.6 .614 0.4 .016 7.62 .300 4.2 .165 0.5 dia. .020 dia. 10.16 .400 0.3 .012 7.62 .300 0.3 .012 7.62 .300 0.8 .031 Coil 1 Form C 10 .394 20 .787 PC board pattern (Copper-side view) 1 Form A 1FormC 10.16 .400 7.62 .300 4-1.3 dia. 4-.051 dia. 10.16 .400 7.62 .300 5-1.3 dia. 5-.051 dia. 15.6 .614 0.4 .016 7.62 .300 4.2 .165 0.5 dia. .020 dia. 10.16 .400 0.3 .012 5.08 .200 2.54 .100 0.3 .012 0.3 .012 7.62 .300 0.8 .031 7.62 .300 7.62 .300 Tolerance: 0.1 .004 Dimension : Max. 1mm .039 inch 1 to 5mm .039 to .118 inch Min. 5mm .118 inch General tolerance 0.2 .008 0.3 .012 0.4 .016 REFERENCE DATA Max. switching capacity (1 Form A type) 100 Contact current, A Max. switching capacity (1 Form C type) 100 AC resistive load (High capacity type) N.O. side AC resistive load (Standard type) N.O. side 10 5 3 2 AC resistive load 1 (High capacity type) N.C. side AC resistive load (Standard type) N.C. side Contact current, A AC resistive load (High capacity type) 10 5 1 AC resistive load (Standard type) 10 100 277 Contact voltage, V 1,000 10 100 277 Contact voltage, V 1,000 Standard type 1-(1). Operate & release time (1 Form A type) Tested sample: JQ1A-12V, 25 pcs. 1-(2). Operate & release time (1 Form C type) Tested sample: JQ1-24V, 25 pcs. 2. Life curve Ambient temperature: room temperature 100 Operate & release time, ms Operate & release time, ms 8 8 Life, x104 125V AC resistive load 6 Operate time 4 Max. Max. Min. Min. 6 Operate time 4 Max. Max. Min. Min. Release time 0 80 100 120 150 10 250V AC resistive load 2 Release time 0 2 1 80 100 120 150 0 1 2 3 4 5 Coil applied voltage, %V Coil applied voltage, %V Contact current, A 73 JQ 3-(1). Coil temperature rise (1 Form A type) Contact carrying current: 3 A, 5 A Measured portion: Inside the coil 50 Temperature rise, C Temperature rise, C 3-(2). Coil temperature rise (1 Form C type) Contact carrying current: 3 A, 5 A Measured portion: Inside the coil 70 60 5 A at 70C 50 3 A at 70C 40 5 A at 85C 30 3 A at 85C 20 10 40 5 A at 70C 5 A at 85C 30 20 3 A at 70C 3 A at 85C 10 0 100 110 120 130 140 150 160 170 180 190 Coil applied voltage, %V 0 100 110 120 130 140 150 160 Coil applied voltage, %V 4-(1). Ambient temperature characteristics (1 Form A type) Tested sample: JQ1a-24V Contact carrying current: 3 A, 5 A 400 Coil applied voltage, %V 4-(2). Ambient temperature characteristics (1 Form C type) Tested sample: JQ1-24V Contact carrying current: 3 A, 5 A 400 Coil applied voltage, %V 300 1 2 200 3 5 100 7 0 20 30 40 50 60 70 80 90 6 4 300 1 200 5 100 6 0 20 30 40 7 50 60 70 80 90 2 3 4 Ambient temperature, C Ambient temperature, C 1 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130C 266F) (Carrying current: 3 A) 2 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130C 266F) (Carrying current: 5 A) 3 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115C 239F) (Carrying current: 3 A) 4 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115C 239F) (Carrying current: 5 A) 5 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 5 A) 6 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 3 A) 7 Pick-up voltage High capacity type 1-(1). Operate & release time (1 Form A type) Tested sample: JQ1aP-12V, 25 pcs. Operate & release time, ms 1-(2). Operate & release time (1 Form C type) Tested sample: JQ1P-12V, 25 pcs. Operate & release time, ms 2. Life curve Ambient temperature: room temperature 100 8 8 Life, x104 6 Operate time 6 Operate time 4 Max. Max. Min. Min. 125V AC resistive load 10 4 2 Max. Min. Max. Min. Release time 2 Release time 250V AC resistive load 0 80 100 120 150 0 80 100 120 150 1 0 2 4 6 8 10 Coil applied voltage, %V Coil applied voltage, %V Contact current, A 3-(1). Coil temperature rise (1 Form A type) Contact carrying current: 5 A, 10 A Measured portion: Inside the coil 70 Temperature rise, C 3-(2). Coil temperature rise (1 Form C type) Contact carrying current: 5 A, 10 A Measured portion: Inside the coil 70 10 A at 85C Temperature rise, C 60 10 A at 70C 50 40 30 20 10 5 A at 70C 5 A at 85C 60 10 A at 85C 50 10 A at 70C 40 30 5 A at 85C 20 10 0 100 120 140 160 180 5 A at 70C 0 100 110 120 130 140 150 160 Coil applied voltage, %V Coil applied voltage, %V 74 JQ 4-(1). Ambient temperature characteristics (1 Form A type) Tested sample: JQ1aP-24V Contact carrying current: 5 A, 10 A 400 Coil applied voltage, %V Coil applied voltage, %V 1 300 2 4-(2). Ambient temperature characteristics (1 Form C type) Tested sample: JQ1P-24V Contact carrying current: 5 A, 10 A 400 300 1 2 200 5 100 3 4 200 5 100 6 0 20 30 3 4 7 40 50 60 70 80 90 0 20 6 30 40 7 50 60 70 80 90 Ambient temperature, C Ambient temperature, C 1 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130C 266F) (Carrying current: 5 A) 2 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130C 266F) (Carrying current: 10 A) 3 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115C 239F) (Carrying current: 5 A) 4 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115C 239F) (Carrying current: 10 A) 5 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 10 A) 6 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 5 A) 7 Pick-up voltage For Cautions for Use, see Relay Technical Information (Page 11 to 39). 12/27/2002 All Rights Reserved, (c) Copyright Matsushita Electric Works, Ltd. 75 Go To Online Catalog |
Price & Availability of JQ1A-12V
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |