SENSITRON SEMICONDUCTOR TECHNICAL DATA Datasheet 4165, Rev. B SPM6G060-120D Three-Phase IGBT BRIDGE, With Gate Driver and Optical Isolation DESCRIPTION: A 1200 VOLT, 60 AMP, THREE PHASE IGBT BRIDGE ELECTRICAL CHARACTERISTICS PER IGBT DEVICE (Tj=250C UNLESS OTHERWISE SPECIFIED) SYMBOL MIN TYP MAX UNIT PARAMETER IGBT SPECIFICATIONS Collector to Emitter Breakdown Voltage IC = 500 A, VGE = 0V Continuous Collector Current TC = 25 OC O BVCES IC ICM VGE IGES ICES 1200 - - 60 40 100 +/-20 +/- 200 V A A V nA TC = 90 C Pulsed Collector Current, Pulse Width limited by TjMax Gate to Emitter Voltage Gate-Emitter Leakage Current , VGE = +/-20V Zero Gate Voltage Collector Current VCE = 1200 V, VGE=0V Ti=25oC VCE = 800 V, VGE=0V Ti=125oC Collector to Emitter Saturation Voltage, IC = 40A, VGE = 15V, Maximum Thermal Resistance Maximum operating Junction Temperature Maximum Storage Junction Temperature Tj = 25 C Tj = 125 C O O 1 10 VCE(SAT) 1.9 2.1 RJC Tjmax Tjmax -40 -55 2.3 0.6 150 150 o mA mA V C/W o o C C * 221 West Industry Court Deer Park, NY 11729 (631) 586 7600 FAX (631) 242 9798 * * World Wide Web Site - http://www.sensitron.com * E-mail Address - sales@sensitron.com * Page 1 of 6 SPM6G060-120D SENSITRON TECHNICAL DATA Datasheet 4165, Rev. B Over-Temperature Shutdown Over-Temperature Shutdown Over-Temperature Output Over-Temperature Shutdown Hysteresis Tsd Tso 90 100 10 20 115 o C 10mV/oC o C ULTRAFAST DIODES RATING AND CHARACTERISTICS Diode Peak Inverse Voltage Continuous Forward Current, TC = 90 C Forward Pulse Current, Pulse Width limited by TjMax Diode Forward Voltage, IF = 40A, Tj = 25 C Tj = 125 OC Diode Reverse Recovery Time (IF=40A, VRR=600V , di/dt=800 A/s) Maximum Thermal Resistance O O PIV IF IFp VF 1200 - 1.8 1.8 40 100 2.3 V A A V trr RJC - 240 - 1.0 nsec o C/W Gate Driver Supply Voltage Input On Current Opto-Isolator Logic High Input Threshold Input Reverse Breakdown Voltage Input Forward Voltage @ Iin = 5mA Under Voltage Lockout ITRIP Reference Voltage (1) VCC HIN, LIN Ith BVin VF VCCUV Itrip-ref tond tr toffd tf - 10 2 5.0 11.5 2.5 - 15 20 5.0 V mA mA V V V V nsec 1.6 1.5 2.6 TBD TBD TBD TBD 1.7 12.5 2.7 - Input-to-Output Turn On Delay Output Turn On Rise Time Input-to-Output Turn Off Delay Output Turn Off Fall Time @ VCC=400V, IC=40A, TC = 25 Input-Output Isolation Voltage 1500 - - V (1) ITRIP Cycle-by cycle current limit is internally set to 43A peak. The set point can be lowered by connecting a resistor between Itrip-ref and Gnd. The set point can be increased by connecting a resistor between Itrip-ref and +5V ref * 221 West Industry Court Deer Park, NY 11729 (631) 586 7600 FAX (631) 242 9798 * * World Wide Web Site - http://www.sensitron.com * E-mail Address - sales@sensitron.com * Page 2 of 6 SPM6G060-120D SENSITRON TECHNICAL DATA Datasheet 4165, Rev. B Pin Description Pin Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Function Isolated Input for High-side IGBT of Phase A Return for Input at 1 NC Isolated Input for Low-side IGBT of Phase A Return for Input at 4 NC Isolated Input for High-side IGBT of Phase B Return for Input at 7 NC Isolated Input for Low-side IGBT of Phase B Return for Input at 10 Isolated Input for High-side IGBT of Phase C Return for Input at 12 Isolated Input for Low-side IGBT of Phase C Return for Input at 14 NC NC Pin Number 18 19 20 21 22 23 24 25 26 27 28 &29 30 & 31 32 & 33 34 & 35 36 & 37 Case Function NC +15V Input +15V Rtn (Signal Ground) SD (3) (3) Fault Output (3) (3) Fault Clear Input +5V Output Over-Current Trip Set Point (3) DC Bus Current Output with Total Gain of 0.06 V/A Case Temperature Output with Gain of 0.010 V/oC Phase A Output Phase B Output Phase C Output DC Bus "+VDC Return" DC Bus "+VDC" Input Isolated From All Terminals * 221 West Industry Court Deer Park, NY 11729 (631) 586 7600 FAX (631) 242 9798 * * World Wide Web Site - http://www.sensitron.com * E-mail Address - sales@sensitron.com * Page 3 of 6 SPM6G060-120D SENSITRON TECHNICAL DATA Datasheet 4165, Rev. B Package Drawing Top View (All dimensions are in inches, tolerance is +/- 0.010") 3.05 * 221 West Industry Court Deer Park, NY 11729 (631) 586 7600 FAX (631) 242 9798 * * World Wide Web Site - http://www.sensitron.com * E-mail Address - sales@sensitron.com * Page 4 of 6 SPM6G060-120D SENSITRON TECHNICAL DATA Datasheet 4165, Rev. B Package Pin Locations (All dimensions are in inches; tolerance is +/- 0.005" unless otherwise specified) * 221 West Industry Court Deer Park, NY 11729 (631) 586 7600 FAX (631) 242 9798 * * World Wide Web Site - http://www.sensitron.com * E-mail Address - sales@sensitron.com * Page 5 of 6 SPM6G060-120D SENSITRON TECHNICAL DATA Datasheet 4165, Rev. B Application Notes: a- Shutdown Feature: 1- Pin 21, SD, is a dual function input/output, active low input. It is internally pulled high. As a low input, it shuts down all IGBTs regardless of the Hin and Lin signals. 2- SD is also internally activated by the over-temperature shutdown, over-current limit, undervoltage shutdown, and desaturation protection. 3- Over-temperature shutdown, and over-current limit are not latching features. 4- Under-voltage shutdown is automatically reset once the VCC rises above the 12.1V threshold limit. 5- Desaturation shutdown is a latching feature and internally reset. 6- When any of the internal protection features is activated, SD is pulled down. 7- SD can be used to shutdown all IGBTs by an external command. An open collector switch shall be used to pull down SD externally. 8- Also, SD can be used as a fault condition output. Low output at SD indicates a fault situation. b- Fault Output Feature: 1- Pin 22, Flt is a dual function pin. It is internally pulled high. If pulled down, it will freeze the status of all the six IGBTs regardless of the Hin and Lin signals 2- Pin 22 as an output reports desaturation protection activation. When desaturation protection is activated a low output for about 9 sec is reported. 3- If any other protection feature is activated, it will not be reported by Pin 22. c- Fault Clear Output: 1- Pin 23, Flt-Clr is a fault clear input. It can be used to reset a latching fault condition, due to desaturation protection. 2- Pin 23 is internally pulled down. A latching fault due to desaturation can be cleared by pulling high this input. 3- An internal fault clear is activated after 100 sec delay. If desired to clear the fault earlier, this input can be used. d- Signal Ground: Pin 20, Signal Gnd is a the signal ground for all signals at Pins 19 through 27. This ground is internally connected to the +VDC Rtn. No external connection shall be established between Signal Gnd and +VDC Rtn. * 221 West Industry Court Deer Park, NY 11729 (631) 586 7600 FAX (631) 242 9798 * * World Wide Web Site - http://www.sensitron.com * E-mail Address - sales@sensitron.com * Page 6 of 6 |
Price & Availability of SPM6G060-120D
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |