If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
ISOLATED DC/DC CONVERTERS 48V Input / 5V/2A or 12V/1A or 24V/0.5A Output 07LC-10T Series * * * * * Isolated High Efficiency High Power Density Excellent Thermal Performance Output Over-voltage Protection * * Low Cost OCP/SCP Description The 07LC-10T Series converters are isolated DC/DC converters that operate from a nominal 48V source. These converters provide up to 12W of output power. These units are designed to be highly efficient and costeffective. Features include remote on/off, short circuit protection, over-current protection, and output overvoltage protection. These converters are provided in a compact, industry standard package. Part Selection Output Voltage 5V 12V 24V Input Voltage 36 - 72V 36 - 72V 36 - 72V Max. Output Current 2A 1A 0.5A Max. Output Power 10W 12W 12W Typical Efficiency 82% 83% 85% Model Number 07LC-10T050 07LC-10T120 07LC-10T240 Note: Add "G" suffix at the end of the model number to indicate Tray Packaging. Absolute Maximum Ratings Parameter Input Voltage (continuous) Input Voltage (peak/surge) Remote On/Off (Active Low) Remote On/Off (Active High) Output Power Ambient Temperature Storage Temperature Min -0.3V -0.3V -0.3V 0C -40C Typ Max 72V 100V 18V 7V 12W 70C 125C Notes 100ms non-repetitive Input Specifications Parameter Input Voltage Input Current (no load) Input Current (full load) Remote Off Input Current (Active Low) Remote Off Input Current (Active High) Input Reflected Ripple Current (pk-pk) Input Reflected Ripple Current (RMS) I2t Inrush Current Transient Turn-on Voltage Threshold Min 36V Typ 25mA 5mA 15mA 5mA 0.039A2s 30V Max 72V 40mA 0.45 A 10mA 10mA 30mA 10mA 0.062A2s Notes Tested with simulated source impedance of 10uH, 5Hz to 20MHz; use a 47uF/100V electrolytic capacitor with ESR = 1 ohm max. at 200KHz at 25C Note: All specifications are typical at nominal input, full load at 25C unless otherwise stated. Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com ISOLATED DC/DC CONVERTERS 48V Input / 5V/2A or 12V/1A or 24V/0.5A Output Output Specifications Parameter Output Voltage Set Point VO=5V VO=12V VO=24V VO=5V VO=12V VO=24V Min 4.850V 11.64V 23.28V 0.2A 0.1A 0.05A 0uF 0uF 0uF Typ 5.00V 12.00V 24.00V 10mV 20 mV 35 mV 15mV 36 mV 48 mV 75mV 3A 1.5A 0.75A TBD 18mV 21mV 45mV 60mV 80mV 120mV 2mS 0% 100mV 100uS 100mV 100uS 150mV 150uS 150mV 150uS 350mV 200uS 350mV 200uS Max 5.150V 12.36V 24.72V 15 mV 36 mV 48 mV 25 mV 60 mV 80 mV 150mV 2A 1A 0.5A 30mV 40mV 70mV 100mV 120mV 180mV 3% 800uF 100uF 20uF 150mV 150uS 150mV 150uS 250mV 200uS 250mV 200uS 500mV 250uS 500mV 250uS Notes Vin=48V for all outputs Line Regulation Load Regulation VO=5V VO=12V VO=24V Regulation Over Temperature (0C to 70C) Output Current VO=5V VO=12V VO=24V Current Limit Threshold (VO= 90% VO, nom) VO=5V VO=12V VO=24V Short Circuit Surge Transient Ripple and Noise (RMS) VO=5V VO=12V VO=24V Ripple and Noise (pk-pk) VO=5V VO=12V VO=24V Turn on Time Overshoot at Turn on Output Capacitance VO=5V VO=12V VO=24V Transient Response 50% ~ 100% Max Load 100% ~ 50% Max Load 50% ~ 100% Max Load 100% ~ 50% Max Load 50% ~ 100% Max Load 100% ~ 50% Max Load Overshoot Settling Time Overshoot Settling Time Overshoot Settling Time Overshoot Settling Time Overshoot Settling Time Overshoot Settling Time A2s 0 - 20MHz Bandwidth with 1uF ceramic load capacitance 0 - 20MHz Bandwidth with 1uF ceramic load capacitance VO=5V VO=12V di/dt = 0.1A/uS; Vin = 48V; Ta = 25C and 1uF ceramic capacitance VO=24V Note: All specifications are typical at nominal input, full load at 25C unless otherwise stated. Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com ISOLATED DC/DC CONVERTERS 48V Input / 5V/2A or 12V/1A or 24V/0.5A Output General Specifications Parameter Efficiency VO=5V VO=12V VO=24V Switching Frequency Output Trim Range Protection Features Overvoltage Protection Setpoint VO=5V VO=12V VO=24V MTBF Isolation Dimensions Inches (L x W x H) Millimeters (L x W x H) Weight 78% 79% 81% 200KHz 95%VO 82% 83% 85% 250KHz 300KHz 105%VO Vin=48V, IO= IO, max Min Typ Max Notes For all outputs - 6.8V 15V 30V 2,000,000 hours 1500 V 1.91 x 0.98 x 0.477 48.51 x 24.89 x 12.12 10.3g Calculated Per Bell Core TR-332 (IO = Nomal; Ta = 25C) - - Note: All specifications are typical at 25C unless otherwise stated. Control Specifications Parameter Remote On/Off Signal Low (Unit On) Active Low Signal High (Unit Off) Signal Low (Unit Off) Active High Signal High (Unit On) Min -0.3V 2.4V -0.3V 2.4V Typ Max 0.8V 18V 0.8V 7V Notes The remote on/off pin open, Unit On. Output Trim Equations Equations for calculating the trim resistor (in k) given the desired adjusted voltage (Vadj) and the nominal output voltage of the converter (Vnom) are shown below. The Trim Down resistor should be connected between the Trim pin and Vout. The Trim Up resistor should be connected between the Trim pin and Ground. Only one of the resistors should be used for any given application. Vout Rtrimdown Module Trim TrimDown nom adj GND R = V A -V -B RTrimUp = Vadj C -D - Vnom A 489.490 113.550 56.410 Vout Module Trim GND Rtrimup Vnom 24 12 5 B 28.310 16.990 51.200 C 26.660 13.020 18.228 D 6.810 6.490 36.500 Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com ISOLATED DC/DC CONVERTERS 48V Input / 5V/2A or 12V/1A or 24V/0.5A Output Efficiency Data 90.00% 85.00% EFFICIENCY 80.00% 75.00% 70.00% 65.00% 60.00% 55.00% 50.00% 0.00 0.50 1.00 1.50 2.00 OUTPUT CURRENT (A) 36V 48V 72V 90.00% 85.00% 80.00% 75.00% 70.00% 65.00% 60.00% 55.00% 50.00% 0.00 0.20 0.40 0.60 0.80 1.00 OUTPUT CURRENT (A) EFFICIENCY 36V 48V 72V 07LC-10T050 07LC-10T120 90.00% 85.00% 80.00% EFFICIENCY 75.00% 70.00% 65.00% 60.00% 55.00% 50.00% 0.05 0.13 0.25 0.38 0.50 36V 48V 72V OUTPUT CURRENT 07LC-10T240 Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com ISOLATED DC/DC CONVERTERS 48V Input / 5V/2A or 12V/1A or 24V/0.5A Output Thermal Derating Curves Vo=5V, Io=2A Vo=12V, Io=1A Vo=24V, Io=0.5A Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com ISOLATED DC/DC CONVERTERS 48V Input / 5V/2A or 12V/1A or 24V/0.5A Output Pin Connections Pin 1 2 3 4 5 6 Function Vin+ VinRemote On/Off Vo+ Trim Vo- Note: Remote On/Off pin open, unit on. (c)2004 Bel Fuse Inc. Specifications subject to change without notice. 120304 CORPORATE Bel Fuse Inc. 206 Van Vorst Street Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com FAR EAST Bel Fuse Ltd. 8F/ 8 Luk Hop Street San Po Kong Kowloon, Hong Kong Tel 852-2328-5515 Fax 852-2352-3706 www.belfuse.com EUROPE Bel Fuse Europe Ltd. Preston Technology Management Centre Marsh Lane, Suite G7, Preston Lancashire, PR1 8UD, U.K. Tel 44-1772-556601 Fax 44-1772-888366 www.belfuse.com |
Price & Availability of 07LC-10T240 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |