If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Features 4:1 Wide Input Voltage Range 15 Watts Output Power 1.6kVDC Isolation UL Certified Fixed Operating Frequency Six-Sided Continuous Shield International Safety Standard Approvals Standard 50.8 x40.6x10.2mm Package Efficiency to 82% POWERLINE DC/DC-Converter RP15S_DEW Series 15 Watt Single & Dual Output Selection Guide 24V and 48V Input Types Part Number Input Range VDC 9-36 9-36 9-36 18-75 18-75 18-75 9-36 9-36 9-36 18-75 18-75 18-75 Output Voltage VDC 5 12 15 5 12 15 5 12 15 5 12 15 Output Current mA 3000 1250 1000 3000 1250 1000 1500 625 500 1500 625 500 Input (4) Current mA 822 801 801 411 401 401 822 801 801 411 401 401 Efficiency(5) Capacitive(6) Load max. % F 79 82 82 80 82 82 80 82 82 80 82 82 6800 890 570 6800 890 570 1700 300 200 1700 300 200 RP15-2405SEW RP15-2412SEW RP15-2415SEW RP15-4805SEW RP15-4812SEW RP15-4815SEW RP15-2405DEW RP15-2412DEW RP15-2415DEW RP15-4805DEW RP15-4812DEW RP15-4815DEW UL-60950-1 Certified Derating-Graph (Ambient Temperature) RP15-4805SEW 125 100 75 Output Power (%) 50 25 50 60 70 Ambient Temperature Range (C) 0 -40 -25 -10 0 80 90 100 125 100 75 Output Power (%) RP15-4805SEW With Heat Sink Natural Convection 50 25 Natural Convection 0 -40 -25 -10 0 50 60 Ambient Temperature Range (C) 70 80 90 100 Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number not shown here please contact our technical customer service at info@recom-development.at 236 July-2006 www.recom-international.com POWERLINE DC/DC-Converter Typical Characteristics RP15-S_DEW Series RP15-4805SEW Efficiency VS Output load 83 82 81 80 79 78 77 76 70 65 50 0.5 RP15-4805SEW Efficiency VS Input Voltage 83 82 81 80 79 78 77 76 75 74 73 36 Efficiency (%) Efficiency (%) 40 45 50 55 60 65 70 75 1 1.5 2 2.5 3 Input Voltage (V) Output Load (A) Specifications (typical at nominal input and 25C unless otherwise noted) Input Voltage Range Input Filter Input Surge Voltage (100 ms max.) Input Reflected Ripple (nominal Vin and full load) (see Note 3) Start Up Time (nominal Vin and constant resistor load) Remote ON/OFF ( see Note 7) ( Positive logic ) Remote OFF input current Output Power Output Voltage Accuracy (full Load and nominal Vin) Output Voltage Adjustability Minimum Load (see Note 1) Line Regulation (low line, high line at full load) Load Regulation (25% to 100% full load) Cross Regulation (asymmetrical load 25%/100% full load) Ripple and Noise (20MHz bandwith) Temperature Coefficient Transient Response (25% load step change) Over Voltage Protection Zener diode clamp (only single) Over Load Protection (% of full load at nominal Vin) Short Circuit Protection Efficiency Isolation Voltage 5V 12V 15V Single Dual DC-DC ON DC-DC OFF Nominal input 24V Input 48V Input 24V nominal input 48V nominal input 9-36VDC 18-75VDC Pi Type 50VDC 100VDC 20mAp-p 20ms typ. Open or 3.5V < Vr < 12V Short or 0V < Vr < 1.2V 20mA 15W max. 2% 10% 10% of full load 0.5% 1% 5% 5% 75mVp-p 0.02%/C max. 500s 6.2V 15V 18V 150% typ Hiccup, automatic recovery see Selection Guide" table 1600VDC min. continued on next page www.recom-international.com July-2006 237 POWERLINE DC/DC-Converter Specifications (typical at nominal input and 25C unless otherwise noted) Isolation Resistance Isolation Capacitance Operating Frequency Operating Temperature Range Maximum Case Temperature Storage Temperature Range Thermal Impedance (see Note 8) Thermal Shock Vibration Relative Humidity Case Material Base Material Potting Material Conducted Emissions (see Note 9) Radiated Emissions ESD Radiated Immunity Fast Transient Surge Conducted Immunity Weight Dimensions MTBF (see Note 2) EN55022 EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 RP15-S_DEW Series 109 min. 300pF max. 270kHz typ. -40C to +85C(with derating) +100C -55C to +105C Natural convection Natural convection with Heat Sink 10C/Watt 8.24C/Watt MIL-STD-810D 10-55Hz, 2G, 30 Min. along X, Y and Z 5% to 95% RH Nickel plated copper Non-conductive black plastic Epoxy (UL94-V0) Level A Level A Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 48g 50.8 x 40.6 x 10.2mm 2041 x 103 hours Notes : 1. The RP15 series requires a minimum of 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices, however they may not meet all listed specification. 2. BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40C (Ground fixed and controlled environment). 3. Simulated source impedance of 12H. 12H inductor in series with +Vin. 4. Maximum value at nominal input voltage and full load of standard type. 5. Typical value at nominal input voltage and full load. 6. Test by minimum Vin and constant resistor load. 7. The pin voltage is referenced to negative input. 8. Heat-sink option, Thermal impedance is 8.24C/Watt for natural convection and the P/N is 7G-0011A. 9. See application notes for EMI-filtering. 238 July-2006 www.recom-international.com POWERLINE DC/DC-Converter Package Style and Pinning (mm) RP15-S_DEW Series 3rd angle projection 50.10 10.20 dia. 1.0 5.6 40.60 45.70 5 17.80 Bottom View 5.10 15.20 1 2 10.20 6 12.70 Pin Connections Pin # 1 2 4 5 6 7 8 Single +Vin -Vin CTRL No Pin +Vout -Vout Trim Dual +Vin -Vin CTRL +Vout Com -Vout Trim 7 4 10.20 8 17.80 Pin Pitch Tolerance 0.35 mm External Output Trimming Output can be externally trimmed by using the method shown below. ( ) for dual output trim 7(7) Trim Up RU 8(8) Trim Down RD 8(8) 6(5) www.recom-international.com July-2006 239 |
Price & Availability of RP15-2405SEW06
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |