 Bulletin I27402 rev. A 09/97
IRKD600.. SERIES
STANDARD DIODES SUPER MAGN-A-pak TM Power Modules
Features
High current capability 3000 VRMS isolating voltage with non-toxic substrate High surge capability High voltage ratings up to 2000V Industrial standard package UL E78996 approved
600 A
Typical Applications
Rectifying bridge for large motor drives Rectifying bridge for large UPS
Major Ratings and Characteristics
Parameters
I F(AV) @ TC I F(RMS) @ TC I FSM I 2t @ 50Hz @ 60Hz @ 50Hz @ 60Hz I 2t VRRM T STG TJ range range range
IRKD600..
600 100 942 100 19.0 20.1 1805 1683 18050 800 to 2000 - 40 to 150 - 40 to 150
Units
A C A C KA KA KA 2s KA 2s KA2s V C C
www.irf.com
1
IRKD600.. Series
Bulletin I27402 rev. A 09/97
ELECTRICAL SPECIFICATIONS Voltage Ratings
Voltage Type number Code
08 IRKD600.. 12 16 20
V RRM , maximum repetitive peak reverse voltage V
800 1200 1600 2000
VRSM , maximum nonrepetitive peak rev. voltage V
900 1300 1700 2100
I RRM max.
@ TJ max.
mA
50
Forward Conduction
Parameter
IF(AV) Maximum average forward current @ Case temperature IF(RMS) Maximum RMS forward current IFSM Maximum peak, one-cycle forward, non-repetitive surge current
IRKD600..
600 100 942 19.0 20.1 16.2 17.2
Units Conditions
A C A KA 180 conduction, half sine wave @ TC = 100C t = 10ms t = 8.3ms t = 10ms t = 8.3ms KA s
2
180 conduction, half sine wave
No voltage reapplied 100% VRRM reapplied No voltage reapplied 100% VRRM reapplied Sinusoidal half wave, Initial TJ = TJ max.
It
2
Maximum I t for fusing
2
1805 1683 1319 1230
t = 10ms t = 8.3ms t = 10ms t = 8.3ms
I2 t
Maximum I2 t for fusing
18050 0.70 0.77 0.28 0.25 1.24
KA 2s t = 0.1 to 10ms, no voltage reapplied V (16.7% x x I F(AV) < I < x IF(AV)), T J = TJ max. (I > x I F(AV)), TJ = TJ max. m (16.7% x x I F(AV) < I < x IF(AV)), T J = TJ max. (I > x I F(AV)), TJ = TJ max. V Ipk = 1800A, TJ = 25C, tp = 10ms sine pulse
VF(TO)1 Low level value of threshold voltage VF(TO)2 High level value of threshold voltage r f1 r f2 VFM Low level value of forward slope resistance High level value of forward slope resistance Maximum forward voltage drop
Blocking
Parameter
VINS IRRM RMS isolation voltage Maximum peak reverse and off-state leakage current
IRKD600..
3000 50
Units Conditions
V mA t=1s TJ = TJ max., rated VRRM applied
2
www.irf.com
IRKD600.. Series
Bulletin I27402 rev. A 09/97
Thermal and Mechanical Specifications
Parameter
TJ Tstg RthJC Max. junction operating temperature range Max. storage temperature range Max. thermal resistance, junction to case RthC-hs Max. thermal resistance, case to heatsink T Mounting torque 10%SMAP to heatsink busbar to SMAP wt Approximate weight Case style 6-8 12 - 15 1500 g See outline table Nm
A mounting compound is recommended and the torque should be rechecked after a period of 3 hours to allow for the spread of the compound
IRKD600..
- 40 to 150 - 40 to 150 0.065
Units Conditions
C
K/W
Per junction, DC operation
0.02
K/W
SUPER MAGN-A-pak
RthJC Conduction
(The following table shows the increment of thermal resistance RthJC when devices operate at different conduction angles than DC)
Conduction angle
180 120 90 60 30
Sinusoidal conduction Rectangular conduction
0.009 0.011 0.014 0.021 0.037 0.006 0.011 0.015 0.022 0.038
Units
Conditions
K/W
TJ = TJ max.
Ordering Information Table
1
Device Code
~
IRK
1 1 2 3 4 Module type
D
2
600
3
-
20
4
+ 2
Circuit configuration D = 2 diodes in series Current rating Voltage code: Code x 100 = VRRM (See Voltage Ratings Table)
3
www.irf.com
3
IRKD600.. Series
Bulletin I27402 rev. A 09/97
Outline Table
All dimensions in millimeters (inches)
Maximum Allowable Case Temperature (C)
140 130 120 110 100
IRKD600.. Series R thJC (DC) = 0.065 K/W
Maximum Allowable Case Temperature (C)
150
150 140 130 120 110 100 30 90 80 0 200 400 600 800 1000 Average Forward Current (A) 60 90 120 180 DC
Conduction Period
IRKD600.. Series R thJC(DC) = 0.065 K/W
Conduction Angle
30 90 80 0 100 200 300
60
90 120 180
400
500
600
700
Average Forward Current (A)
Fig. 1 - Current Ratings Characteristics
Fig. 2 - Current Ratings Characteristics
4
www.irf.com
IRKD600.. Series
Bulletin I27402 rev. A 09/97
Maximum Average Forward Power Loss (W)
Maximum Average Forward Power Loss (W) 700 600 500 400 300 200 100 0 0 100 200 300 400 500 600 Average Forward Current (A)
Conduction Angle
1000 900 800 700 600 500 400 300 200 100 0 0 200 400 600 800 1000 Average Forward Current (A) IRKD600.. Series Per Junction T J= 150C RMS Limit
Conduction Period
180 120 90 60 30 RMS Limit
DC 180 120 90 60 30
IRKD600.. Series Per Junction TJ = 150C
Fig. 3 - Forward Power Loss Characteristics
Peak Half Sine Wave Forward Current (A) 18000
Fig. 4 - Forward Power Loss Characteristics
20000 18000 16000 14000 12000 10000 8000 6000 4000 0.01 IRKD600.. Series Per Junction 0.1 Pulse Train Duration (s) 1
Peak Half Sine Wave Forward Current (A)
At Any Rated Load Condition And With Rated V RRM Applied Following Surge. 16000 Initial TJ = 150C @ 60 Hz 0.0083 s 14000 @ 50 Hz 0.0100 s 12000 10000 8000 6000 4000 1 10 100
Number Of Equal Amplitude Half Cycle Curre nt Pulses (N)
Maximum Non Repetitive Surge Current Versus Pulse Train Duration. Initial T J = 150C No Voltage Reapplied Rated VRRM Reapplied
IRKD600.. Series Per Junction
Fig. 5 - Maximum Non-Repetitive Surge Current
1000
Fig. 6 - Maximum Non-Repetitive Surge Current
Maximum Total Forward Power Loss (W)
SA R th
0.
DC 800
0. 08
06 0.
K/ W
04
W
K/
W K/
= 02 0.
0. 1
600
180 (Sine)
0 .1
K/ W 6K /W
2
W K/ -D elt a
400 IRKD600.. Series Per Junction TJ = 150C 0 200 400 600 800
0.2 5K /W 0.3 5K /W 0.5 K /W
R
200
0 0 1000 25 50 75 100 125 150
Total RMS Output Current (A)
Maximum Allowable Ambient Temperature (C)
Fig. 7 - Forward Power Loss Characteristics
www.irf.com
5
IRKD600.. Series
Bulletin I27402 rev. A 09/97
3000
R th
02 0.
Maximum Total Power Loss (W)
2500 2000 1500 1000 500 0 0 200 400
180 (Sine) 180 (Rect)
K /W K/ W 0. 05 K/ W
0. 04
0. 0 8
0.12
0. 03
SA
W K/
= 01 0. W K/ ta el -D R
K/ W
K/W
2 x IRKD600.. Series 0.2 K /W Single Phase Bridge Conn ected T J = 150C 600 800 1000 0 1200 25 50 75 100 125 150
Total Output Current (A)
Maximum Allowable Ambient Temperature (C)
Fig. 8 - Forward Power Loss Characteristics
4500
Rt
Maximum Total Power Loss (W)
4000 3500 3000 2500 2000 1500 1000 500 0 0 300 600 900 1200 1500 0 1800 3 x IRKD600.. Series Three Phase Bridge Connected T J = 150C
0.
A hS
=
120 (Rect)
02
01 0. /W K
K/ W
0 .0 3
-
K/ W
D e lta R
/W 0 .0 8 K/ W 0.12 K /W
0.0 5K
0.2 K /W
25
50
75
100
125
150
Total Output Current (A)
Maximum Allowable Ambient Temperature (C)
Fig. 9 - Forward Power Loss Characteristics
10000 Instantaneous Forward Current (A)
0.1 IRKD600.. Series Per Junction
1000 T J= 25C T J= 150C
Transient Thermal Impedance Z thJ C (K/W)
0.01
Steady State Value: R thJC = 0.065 K/W (DC Operation) 0.001 0.001 0.01 0.1 1 10 100
IRKD600.. Series Per Junction 100 0.5 1 1.5 2 2.5 3 3.5
Instantaneous Forward Voltage (V)
Square Wave Pulse Duration (s)
Fig. 10 - Forward Voltage Drop Characteristics
Fig. 11 - Thermal Impedance ZthJC Characteristic
6
www.irf.com


▲Up To Search▲   

 
Price & Availability of 2195

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X