Part Number Hot Search : 
P5KE64 26S3R3 3194B ITD3020 8GXXX SXX48 HA13614 101111F
Product Description
Full Text Search
 

To Download 74AC163 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 74AC163 * 74ACT163 Synchronous Presettable Binary Counter
November 1988 Revised February 2000
74AC163 * 74ACT163 Synchronous Presettable Binary Counter
General Description
The AC/ACT163 are high-speed synchronous modulo-16 binary counters. They are synchronously presettable for application in programmable dividers and have two types of Count Enable inputs plus a Terminal Count output for versatility in forming synchronous multistage counters. The AC/ACT163 has a Synchronous Reset input that overrides counting and parallel loading and allows the outputs to be simultaneously reset on the rising edge of the clock.
Features
s ICC reduced by 50% s Synchronous counting and loading s High-speed synchronous expansion s Typical count rate of 125 MHz s Outputs source/sink 24 mA s ACT163 has TTL-compatible inputs
Ordering Code:
Order Number 74AC163SC 74AC163SJ 74AC163MTC 74AC163PC 74ACT163SC 74ACT163SJ 74ACT163MTC 74ACT163PC Package Number M16A M16D MTC16 N16E M16A M16D MTC16 N16E Package Description 16-Lead Small Outline Integrated Circuit (SOIC), JEDEC MS-012, 0.150" Narrow Body 16-Lead Small Outline Package, (SOP), EIAJ TYPE II, 5.3mm Wide 16-Lead Thin Shrink Small Outline Package (TSSOP), JEDEC MO-153, 4.4mm Wide 16-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300" Wide 16-Lead Small Outline Integrated Circuit (SOIC), JEDEC MS-012, 0.150" Narrow Body 16-Lead Small Outline Package, (SOP), EIAJ TYPE II, 5.3mm Wide 16-Lead Thin Shrink Small Outline Package (TSSOP), JEDEC MO-153, 4.4mm Wide 16-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300" Wide
Device also available in Tape and Reel. Specify by appending suffix letter "X" to the ordering code.
Connection Diagram
Pin Descriptions
Pin Names CEP CET CP SR P0-P3 PE Q0-Q3 TC Description Count Enable Parallel Input Count Enable Trickle Input Clock Pulse Input Synchronous Reset Input Parallel Data Inputs Parallel Enable Input Flip-Flop Outputs Terminal Count Output
(c) 2000 Fairchild Semiconductor Corporation
DS009932
www.fairchildsemi.com
74AC163 * 74ACT163
Logic Symbols
Functional Description
The AC/ACT163 counts in modulo-16 binary sequence. From state 15 (HHHH) it increments to state 0 (LLLL). The clock inputs of all flip-flops are driven in parallel through a clock buffer. Thus all changes of the Q outputs occur as a result of, and synchronous with, the LOW-to-HIGH transition of the CP input signal. The circuits have four fundamental modes of operation, in order of precedence: synchronous reset, parallel load, count-up and hold. Four control inputs--Synchronous Reset (SR), Parallel Enable (PE), Count Enable Parallel (CEP) and Count Enable Trickle (CET)--determine the mode of operation, as shown in the Mode Select Table. A LOW signal on SR overrides counting and parallel loading and allows all outputs to go LOW on the next rising edge of CP. A LOW signal on PE overrides counting and allows information on the Parallel Data (Pn) inputs to be loaded into the flip-flops on the next rising edge of CP. With PE and SR HIGH, CEP and CET permit counting when both are HIGH. Conversely, a LOW signal on either CEP or CET inhibits counting. The AC/ACT163 uses D-type edge-triggered flip-flops and changing the SR, PE, CEP and CET inputs when the CP is in either state does not cause errors, provided that the recommended setup and hold times, with respect to the rising edge of CP, are observed. The Terminal Count (TC) output is HIGH when CET is HIGH and counter is in state 15. To implement synchronous multistage counters, the TC outputs can be used with the CEP and CET inputs in two different ways. Action on the Rising Clock Edge () Figure 1 shows the connections for simple ripple carry, in which the clock period must be longer than the CP to TC delay of the first stage, plus the cumulative CET to TC delays of the intermediate stages, plus the CET to CP setup time of the last stage. This total delay plus setup time sets the upper limit on clock frequency. For faster clock rates, the carry lookahead connections shown in Figure 2 are recommended. In this scheme the ripple delay through the intermediate stages commences with the same clock that causes the first stage to tick over from max to min in the Up mode, or min to max in the Down mode, to start its final cycle. Since this final cycle takes 16 clocks to complete, there is plenty of time for the ripple to progress through the intermediate stages. The critical timing that limits the clock period is the CP to TC delay of the first stage plus the CEP to CP setup time of the last stage. The TC output is subject to decoding spikes due to internal race conditions and is therefore not recommended for use as a clock or asynchronous reset for flip-flops, registers or counters. Logic Equations: Count Enable = CEP * CET * PE TC = Q0 * Q1 * Q2 * Q3 * CET
IEEE/IEC
Mode Select Table
SR PE CET CEP
L H H H H
X L H H H
X X H L X
X X H X L
Reset (Clear) Load (Pn Qn) Count (Increment) No Change (Hold) No Change (Hold)
H = HIGH Voltage Level L = LOW Voltage Level X = Immaterial
www.fairchildsemi.com
2
74AC163 * 74ACT163
State Diagram
FIGURE 1.
FIGURE 2.
Block Diagram
Please note that this diagram is provided only for the understanding of logic operations and should not be used to estimate propagation delays.
3
www.fairchildsemi.com
74AC163 * 74ACT163
Absolute Maximum Ratings(Note 1)
Supply Voltage (VCC) DC Input Diode Current (IIK) VI = -0.5V VI = VCC + 0.5V DC Input Voltage (VI) DC Output Diode Current (IOK) VO = -0.5V VO = VCC + 0.5V DC Output Voltage (VO) DC Output Source or Sink Current (IO) DC VCC or Ground Current per Output Pin (ICC or IGND) Storage Temperature (TSTG) Junction Temperature (TJ) PDIP 140C 50 mA -65C to +150C 50 mA -20 mA +20 mA -0.5V to VCC + 0.5V -20 mA +20 mA -0.5V to VCC + 0.5V -0.5V to +7.0V
Recommended Operating Conditions
Supply Voltage (VCC) AC ACT Input Voltage (VI) Output Voltage (VO) Operating Temperature (TA) Minimum Input Edge Rate (V/t) AC Devices VIN from 30% to 70% of VCC VCC @ 3.3V, 4.5V, 5.5V Minimum Input Edge Rate (V/t) ACT Devices VIN from 0.8V to 2.0V VCC @ 4.5V, 5.5V 125 mV/ns
Note 1: Absolute maximum ratings are those values beyond which damage to the device may occur. The databook specifications should be met, without exception, to ensure that the system design is reliable over its power supply, temperature, and output/input loading variables. Fairchild does not recommend operation of circuits outside databook specifications.
2.0V to 6.0V 4.5V to 5.5V 0V to VCC 0V to VCC -40C to +85C
125 mV/ns
DC Electrical Characteristics for AC
Symbol VIH Parameter Minimum HIGH Level Input Voltage VIL Maximum LOW Level Input Voltage VOH Minimum HIGH Level Output Voltage VCC (V) 3.0 4.5 5.5 3.0 4.5 5.5 3.0 4.5 5.5 3.0 4.5 5.5 VOL Maximum LOW Level Output Voltage 3.0 4.5 5.5 3.0 4.5 5.5 IIN (Note 4) Maximum Input Leakage Current IOLD IOHD ICC (Note 4) Minimum Dynamic Output Current (Note 3) Maximum Quiescent Supply Current 5.5 5.5 5.5 5.5 4.0 0.002 0.001 0.001 TA = +25C Typ 1.5 2.25 2.75 1.5 2.25 2.75 2.99 4.49 5.49 2.1 3.15 3.85 0.9 1.35 1.65 2.9 4.4 5.4 2.56 3.86 4.86 0.1 0.1 0.1 0.36 0.36 0.36 0.1 TA = -40C to +85C Guaranteed Limits 2.1 3.15 3.85 0.9 1.35 1.65 2.9 4.4 5.4 VIN = VIL or VIH 2.46 3.76 4.76 0.1 0.1 0.1 VIN = VILor VIH 0.44 0.44 0.44 1.0 75 -75 40.0 A mA mA A V IOL = 12 mA IOL = 24 mA IOL = 24 mA (Note 2) VI = VCC, GND VOLD = 1.65V Max VOHD = 3.85V Min VIN = VCC or GND V IOUT = 50 A V IOH = -12 mA IOH = -24 mA IOH = -24 mA (Note 2) V IOUT = -50 A V VOUT = 0.1V or VCC - 0.1V V Units Conditions VOUT = 0.1V or VCC - 0.1V
Note 2: All outputs loaded; thresholds on input associated with output under test. Note 3: Maximum test duration 2.0 ms, one output loaded at a time. Note 4: IIN and ICC @ 3.0V are guaranteed to be less than or equal to the respective limit @ 5.5V VCC.
www.fairchildsemi.com
4
74AC163 * 74ACT163
DC Electrical Characteristics for ACT
Symbol VIH VIL VOH Parameter Minimum HIGH Level Input Voltage Maximum LOW Level Input Voltage Minimum HIGH Level Output Voltage VCC (V) 4.5 5.5 4.5 5.5 4.5 5.5 4.5 5.5 VOL Maximum LOW Level Output Voltage 4.5 5.5 4.5 5.5 IIN ICCT IOLD IOHD ICC Maximum Input Leakage Current Maximum ICC/Input Minimum Dynamic Output Current (Note 6) Maximum Quiescent Supply Current
Note 5: All outputs loaded; thresholds on input associated with output under test. Note 6: Maximum test duration 2.0 ms, one output loaded at a time.
TA = +25C Typ 1.5 1.5 1.5 1.5 4.49 5.49 2.0 0.8 0.8 4.4 5.4 3.86 4.86 0.001 0.001 0.1 0.1 0.36 0.36 0.1 0.6 2.0
TA = -40C to +85C Guaranteed Limits 2.0 2.0 0.8 0.8 4.4 5.4 3.76 4.76 0.1 0.1 0.44 0.44 1.0 1.5 75 -75
Units V V V
Conditions VOUT = 0.1V or VCC - 0.1V VOUT = 0.1V or VCC - 0.1V IOUT = -50 A VIN = VIL or VIH
V
IOH = -24 mA IOH = -24 mA (Note 5)
V
IOUT = 50 A VIN = VIL or VIH
V A mA mA mA A
IOL = 24 mA IOL = 24 mA (Note 5) VI = VCC, GND VI = VCC - 2.1V VOLD = 1.65V Max VOHD = 3.85V Min VIN = VCC or GND
5.5 5.5 5.5 5.5 5.5
4.0
40.0
AC Electrical Characteristics for AC
VCC Symbol Parameter (V) (Note 7) fMAX Maximum Clock Frequency tPLH Propagation Delay, CP to Qn (PE Input HIGH or LOW) tPHL Propagation Delay, CP to Qn (PE Input HIGH or LOW) tPLH Propagation Delay CP to TC tPHL Propagation Delay CP to TC tPLH Propagation Delay CET to TC tPHL Propagation Delay CET to TC
Note 7: Voltage Range 3.3 is 3.3V 0.3V Voltage Range 5.0 is 5.0V 0.5V
TA = +25C CL = 50 pF Min 70 110 2.0 1.5 1.5 1.5 3.0 2.0 3.5 2.0 2.0 1.5 2.5 2.0 Typ 95 140 7.5 5.5 8.5 6.0 9.5 7.0 11.0 8.0 7.5 5.5 8.5 6.0 12.5 9.0 12.0 9.5 15.0 10.5 14.0 11.0 9.5 6.5 11.0 8.5 Max
TA = -40C to +85C CL = 50 pF Min 60 MHz 95 1.5 1.0 1.5 1.5 2.5 1.5 2.5 2.0 1.5 1.0 2.0 1.5 13.5 ns 9.5 13.0 ns 10.0 16.5 ns 11.5 15.5 ns 11.5 11.0 ns 7.5 12.5 ns 9.5 Max Units
3.3 5.0 3.3 5.0 3.3 5.0 3.3 5.0 3.3 5.0 3.3 5.0 3.3 5.0
5
www.fairchildsemi.com
74AC163 * 74ACT163
AC Operating Requirements for AC
VCC Symbol Parameter (V) (Note 8) tS Setup Time, HIGH or LOW Pn to CP tH Hold Time, HIGH or LOW Pn to CP tS Setup Time, HIGH or LOW SR to CP tH Hold Time, HIGH or LOW SR to CP tS Setup Time, HIGH or LOW PE to CP tH Hold Time, HIGH or LOW PE to CP tS Setup Time, HIGH or LOW CEP or CET to CP tH Hold Time, HIGH or LOW CEP or CET to CP tW Clock Pulse Width (Load) HIGH or LOW tW Clock Pulse Width (Count) HIGH or LOW
Note 8: Voltage Range 3.3 is 3.3V 0.3V Voltage Range 5.0 is 5.0V 0.5V
TA = +25C CL = 50 pF Typ 5.5 4.0 -7.0 -5.0 5.5 4.0 -7.5 -5.5 5.5 4.0 -7.5 -5.0 3.5 2.5 -4.5 -3.0 3.0 2.0 3.0 2.0
TA = -40C to +85C CL = 50 pF Guaranteed Minimum Units
3.3 5.0 3.3 5.0 3.3 5.0 3.3 5.0 3.3 5.0 3.3 5.0 3.3 5.0 3.3 5.0 3.3 5.0 3.3 5.0
13.5 8.5 -1.0 0 14.0 9.5 -1.0 -0.5 11.5 7.5 -1.0 -0.5 6.0 4.5 0 0 3.5 2.5 4.0 3.0
16.0 ns 10.5 -0.5 0 16.5 ns 11.0 -0.5 0 14.0 ns 8.5 -0.5 0 7.0 ns 5.0 0 ns 0.5 4.0 ns 3.0 4.5 ns 3.5 ns ns ns
AC Electrical Characteristics for ACT
VCC Symbol Parameter (V) (Note 9) fMAX tPLH Maximum Clock Frequency Propagation Delay, CP to Qn (PE Input HIGH or LOW) tPHL Propagation Delay, CP to Qn (PE Input HIGH or LOW) tPLH Propagation Delay 5.0 CP to TC tPHL Propagation Delay 5.0 CP to TC tPLH Propagation Delay 5.0 CET to TC tPHL Propagation Delay 5.0 CET to TC
Note 9: Voltage Range 5.0 is 5.0V 0.5V
TA = +25C CL = 50 pF Min 120 1.5 Typ 140 5.5 10.0 Max
TA = -40C to +85C CL = 50 pF Min 105 1.5 11.0 Max MHz ns Units
5.0 5.0
5.0
1.5
6.0
11.0
1.5
12.0
ns
2.5
7.0
11.5
2.0
13.5
ns
3.0
8.0
13.5
2.0
15.0
ns
2.0
5.5
9.0
1.5
10.5
ns
2.0
6.0
10.0
2.0
11.0
ns
www.fairchildsemi.com
6
74AC163 * 74ACT163
AC Operating Requirements for ACT
VCC Symbol Parameter (V) (Note 10) tS Setup Time, HIGH or LOW 5.0 Pn to CP tH Hold Time, HIGH or LOW 5.0 Pn to CP tS Setup Time, HIGH or LOW 5.0 SR to CP tH Hold Time, HIGH or LOW 5.0 SR to CP tS Setup Time, HIGH or LOW 5.0 PE to CP tH Hold Time, HIGH or LOW 5.0 PE to CP tS Setup Time, HIGH or LOW 5.0 CEP or CET to CP tH Hold Time, HIGH or LOW 5.0 CEP or CET to CP tW Clock Pulse Width (Load) 5.0 HIGH or LOW tW Clock Pulse Width 5.0 (Count) HIGH or LOW
Note 10: Voltage Range 5.0 is 5.0V 0.5V
TA = +25C CL = 50 pF Typ 4.0
TA = -40C to +85C CL = 50 pF Guaranteed Minimum Units
10.0
12.0
ns
-5.0
0.5
0.5
ns
4.0
10.0
11.5
ns
-5.5
-0.5
-0.5
ns
4.0
8.5
10.5
ns
-5.5
-0.5
0
ns
2.5
5.5
6.5
ns
-3.0
0
0.5
ns
2.0
3.5
3.5
ns
2.0
3.5
3.5
ns
Capacitance
Symbol CIN CPD Parameter Input Capacitance Power Dissipation Capacitance Typ 4.5 45.0 Units pF pF VCC = OPEN VCC = 5.0V Conditions
7
www.fairchildsemi.com
74AC163 * 74ACT163
Physical Dimensions inches (millimeters) unless otherwise noted
16-Lead Small Outline Integrated Circuit (SOIC), JEDEC MS-012, 0.150" Narrow Body Package Number M16A
www.fairchildsemi.com
8
74AC163 * 74ACT163
Physical Dimensions inches (millimeters) unless otherwise noted (Continued)
16-Lead Small Outline Package (SOP), EIAJ TYPE II, 5.3mm Wide Package Number M16D
9
www.fairchildsemi.com
74AC163 * 74ACT163
Physical Dimensions inches (millimeters) unless otherwise noted (Continued)
16-Lead Thin Shrink Small Outline Package (TSSOP), JEDEC MO-153, 4.4mm Wide Package Number MTC16
www.fairchildsemi.com
10
74AC163 * 74ACT163 Synchronous Presettable Binary Counter
Physical Dimensions inches (millimeters) unless otherwise noted (Continued)
16-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300" Wide Package Number N16E
Fairchild does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and Fairchild reserves the right at any time without notice to change said circuitry and specifications. LIFE SUPPORT POLICY FAIRCHILD'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. 11 2. A critical component in any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. www.fairchildsemi.com
www.fairchildsemi.com


▲Up To Search▲   

 
Price & Availability of 74AC163

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X