![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Features Regulated Converters 3W DIP Package Isolated Dual Outputs Vout1 / Vout2 Input / Output 2KVDC Isolation min. UL94V-0 Package Material Continuous Short Circuit Protection Auto-Restarting (V1) Wide Input 2:1 Internal SMD design 100% Burned In ECONOLINE DC/DC-Converter REC3DRWI/A Series 3 Watt DIP24 Isolated Dual Output Selection Guide Part Number DIP24 REC3-050505DRWI/A REC3-050509DRWI/A REC3-050512DRWI/A REC3-050515DRWI/A REC3-120505DRWI/A REC3-120509DRWI/A REC3-120512DRWI/A REC3-120515DRWI/A REC3-240505DRWI/A REC3-240509DRWI/A REC3-240512DRWI/A REC3-240515DRWI/A REC3-480505DRWI/A REC3-480509DRWI/A REC3-480512DRWI/A REC3-480515DRWI/A Input Voltage (VDC) 4.5-9 4.5-9 4.5-9 4.5-9 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 36-72 36-72 36-72 36-72 Output Voltage Vout1(VDC) 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Output Current at Vout1(mA) 300* 300* 300* 300* 300* 300* 300* 300* 300* 300* 300* 300* 300* 300* 300* 300* Output Voltage 5 9 12 15 5 9 12 15 5 9 12 15 5 9 12 15 Output Current 300 167 125 100 300 167 125 100 300 167 125 100 300 167 125 100 Vout2(VDC) at Vout2(mA) EN-60950-1 Certified EN-60601-1 Certified UL-60950-1 Certified * V1 min. load 100mA to supply V2 well * add suffix "M" for Metal Case, e.g. REC3-240505DRWI/AM For alternative custom output voltage and power combinations, please contact Recom Technical Support Specifications (Core Operating Area) Input Voltage Range Output Voltage Accuracy Line Voltage Regulation Load Voltage Regulation (10% to 100% full load ) Output Ripple and Noise (at 20MHz BW) Operating Frequency No Load Power Consumption Isolation Voltage Input / Output (tested for 1 second) Vout1 / Vout2 (tested for 1 second) Rated Working Voltage (long term isolation) Isolation Capacitance Isolation Resistance Short Circuit Protection (V1) Operating Temperature Range (free air convection) Storage Temperature Range Vin=5V Vin=12, 24, 48V 2:1 2% max. 0.4% max. 0.6% max. 50mVp-p max. 100kHz typ. 300mW max. 2000VDC min. 500VDC min. see Application Notes 40pF typ. 1 G min. Continuous -40C to +80C (see Graph) -40C to +85C (see Graph) -55C to +125C continued on next page www.recom-international.com January-2007 109 ECONOLINE DC/DC-Converter Specifications (Core Operating Area) Relative Humidity Case Material Thermal Impedance Package Weight MTBF (+25C) (+80C) Detailed Information see Application Notes chapter "MTBF" REC3-DRWI/A Series 95% RH Non-Conductive Plastic Natural convection using MIL-HDBK 217F using MIL-HDBK 217F 20C/W for metal case 13g 877 x 10 hours 138 x 103 hours 3 Derating-Graph (Ambient Temperature) Vin = 5V 100 80 (2W) 67 60 (1.5W) 50 40 Vin = 12, 24, 48V 100 80 (2W) 67 60 (1.5W) 50 40 Output Power (%) Output Power (%) 20 0 Safe Operating Area 0 50 150 20 0 -40 Safe Operating Area 0 50 150 100 80 105 96 Operating Temperature C -40 100 85 105 98 Operating Temperature C Package Style and Pinning (mm) Wide Input 2:1 3rd angle projection 24 PIN DIP Package 32.00 10.20 3.81 4.60 0.51 20.30 Pin Connections Pin # 2 3 Dual -Vin -Vin +Vout 2 -Vout 2 +Vout 1 -Vout 1 +Vin +Vin 15.24 9 11 14 16 22 23 Recommended Footprint Details 1.00 o+0.15/0 23 Bottom View 23 22 16 14 Top View 9 11 NC = No Connection XX.X 0.5 mm XX.XX 0.25 mm 2.54 2.54 110 January-2007 www.recom-international.com |
Price & Availability of REC3-050505DRWIA
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |