If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Bulletin I2059 rev. C 03/03 400U(R) SERIES STANDARD RECOVERY DIODES Stud Version Features Wide current range High surge current capabilities Stud cathode and stud anode version Standard JEDEC types 400A Typical Applications Converters Power supplies Machine tool controls High power drives Major Ratings and Characteristics Parameters IF(AV) @ TC IF(RMS) IFSM @ 50Hz @ 60Hz I2t @ 50Hz @ 60Hz V RRM range TJ 400U/R 400 120 630 8250 8640 340 311 800 to 1600 - 40 to 200 Units A C A A A KA2s KA2s V C case style DO-205AB (DO-9) www.irf.com 1 400U(R) Series Bulletin I2059 rev. C 03/03 ELECTRICAL SPECIFICATIONS Voltage Ratings Voltage Type number Code 80 400U(R) 120 160 VRRM , maximum repetitive peak reverse voltage V 800 1200 1600 VRSM , maximum nonrepetitive peak rev. voltage V 900 1300 1700 IRRM max. @ TJ = TJ max. mA 15 Forward Conduction Parameter I F(AV) Max. average forward current @ Case temperature I F(RMS) Max. RMS forward current I FSM Max. peak, one-cycle forward, non-repetitive surge current 400U(R) 400 120 630 8250 8640 6940 7270 Units Conditions A C A DC @ 110C case temperature t = 10ms A t = 8.3ms t = 10ms t = 8.3ms t = 10ms KA2s t = 8.3ms t = 10ms t = 8.3ms KA2s No voltage reapplied 100% VRRM reapplied No voltage reapplied 100% VRRM reapplied Sinusoidal half wave, Initial TJ = TJ max. 180 conduction, half sine wave I 2t Maximum I2t for fusing 340 311 241 220 I 2 t Maximum I2t for fusing 3400 0.77 t = 0.1 to 10ms, no voltage reapplied (16.7% x x IF(AV) < I < x IF(AV)), TJ = TJ max. V F(TO)1 Low level value of threshold voltage V F(TO)2 High level value of threshold voltage r f1 r f2 V FM Low level value of forward slope resistance High level value of forward slope resistance Max. forward voltage drop V 0.85 (I > x IF(AV)),TJ = TJ max. (16.7% x x IF(AV) < I < x IF(AV)), TJ = TJ max. m 0.49 1.62 V (I > x IF(AV)),TJ = TJ max. Ipk= 1500A, TJ = TJ max, tp = 10ms sinusoidal wave 0.49 Thermal and Mechanical Specifications Parameter TJ Tstg RthJC RthCS T wt Max. junction operating temperature range Max. storage temperature range Max. thermal resistance, junction to case Max. thermal resistance, case to heatsink Max. allowed mounting torque 10% Approximate weight Case style 400U(R) -40 to 200 -40 to 200 0.15 0.04 27 250 Units C Conditions K/W Nm g DC operation Mounting surface, smooth, flat and greased Not lubricated threads DO-205AB (DO-9) See Outline Table 2 www.irf.com 400U(R) Series Bulletin I2059 rev. C 03/03 RthJC Conduction (The following table shows the increment of thermal resistence RthJC when devices operate at different conduction angles than DC) Conduction angle 180 120 90 60 30 Sinusoidal conduction 0.020 0.023 0.029 0.042 0.073 Rectangular conduction Units 0.013 0.023 0.031 0.044 0.074 K/W Conditions TJ = TJ max. Ordering Information Table Device Code 40 1 0 2 U 3 R 4 160 5 D 6 1 2 3 4 5 6 - 40 0 U = Essential Part Number = Standard Recovery Device = Stud Normal Polarity (Cathode to Stud) None = Stud Normal Polarity (Cathode to Stud) R = Stud Reverse Polarity (Anode to Stud) Voltage code: Code x 10 = VRRM (See Voltage Ratings table) Diffused diode NOTE: For Metric device M16 x 1.5 Contact Factory Outline Table Conforms to JEDEC DO-205AB (DO-9) All dimensions in millimeters (inches) * FOR METRIC DEVICE: M16 X 1.5 CONTACT FACTORY www.irf.com 3 400U(R) Series Bulletin I2059 rev. C 03/03 Maximum Allowable Case Temperature (C) 200 190 180 170 160 150 140 130 120 110 100 90 80 0 Maximum Allowable Case Temperature (C) 200 190 180 170 160 150 140 130 120 30 60 90 120 DC 180 400U/R 400U/R Conduction Angle Conduction Period 180 120 30 60 90 110 0 100 200 300 400 500 Average Forward Current (A) Fig. 2 - Current Ratings Characteristics 50 100 150 200 250 300 350 400 450 Average Forward Current (A) Fig. 1 - Current Ratings Characteristics Maximum Average Forward Power Loss (W) 550 500 450 400 350 300 250 200 150 100 Conduction Angle 180 120 90 60 30 RMS Limit 1 0. = SA Rth 0. 2 W K/ K/ W 0.3 K/ W 0.4 K/W /W 4K 0.0 R elta -D 0.6 K/W 1 K/ W 1.8 K/W 50 400U/R 0 10 50 100 150 200 250 300 350 400 450 30 50 70 90 110 130 150 170 190 Average Forward Current (A) Maximum Allowable Ambient Temperature (C) Fig. 3 - Forward Power Loss Characteristics Maximum Average Forward Power Loss (W) 800 700 600 500 400 300 200 100 0 50 150 250 350 400U/R RMS Limit Conduction Period DC 180 120 90 60 30 A hS Rt = /W 4K 0.0 aR elt -D 0.1 K/ W 0.2 K/ W 0.3 K/W 0.4 K/W 0.6 K/W 1 K/W 1.8 K/W 450 550 650 30 50 70 90 110 130 150 170 190 10 Maximum Allowable Ambient Temperature (C) Average Forward Current (A) Fig. 4 - Forward Power Loss Characteristics 4 www.irf.com 400U(R) Series Bulletin I2059 rev. C 03/03 Peak Half Sine Wave Forward Current (A) 8000 7000 6000 5000 4000 3000 2000 1 Peak Half Sine Wave Forward Current (A) At Any Rated Load Condition And With Rated Vrrm Applied Following Surge. Initial Tj = 190C @ 60 Hz 0.0083 s @ 50 Hz 0.0100 s 9000 8000 7000 6000 5000 4000 3000 2000 Maximum Non Repetitive Surge Current Versus Pulse Train Duration. Initial Tj = 190C No Voltage Reapplied Rated Vrrm Reapplied 400U/R 400U/R 10 100 1000 0.01 0.1 Pulse Train Duration (s) 1 Number Of Equal Amplitude Half Cycle Current Pulses (N) Fig. 5 - Maximum Non-Repetitive Surge Current Fig. 6 - Maximum Non-Repetitive Surge Current 10000 Instantaneous Forward Current (A) 400U/R 1000 Tj = 25C Tj = 190C 100 0.5 1 1.5 2 2.5 Instantaneous Forward Voltage (V) Fig. 7 - Forward Voltage Drop Characteristics Transient Thermal Impedance ZthJC (K/W) 1 Steady State Value: RthJC = 0.15 K/W (DC Operation) 0.1 0.01 400U/R 0.001 0.001 0.01 0.1 Square Wave Pulse Duration (s) 1 10 Fig. 8 - Thermal Impedance Z thJC Characteristic www.irf.com 5 400U(R) Series Bulletin I2059 rev. C 03/03 Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level. Qualification Standards can be found on IR's Web site. IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 03/03 6 www.irf.com |
Price & Availability of 400UR80D
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |