![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Voltage Transducer AV 100-2000 For the electronic measurement of voltages : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high voltage) and the secondary circuit (electronic circuit). VPN = 2000 V Electrical data VPN VPmax Primary nominal r.m.s. voltage Primary voltage measuring range Non-measurable overload Primary input resistance Measuring resistance @ VC=11.4V @ VC=22.8V Secondary nominal r.m.s. current Supply voltage ( 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 min Max Common mode voltage and R.m.s. voltage for partial discharge extinction @ 10pC 2000 V 30001) V 4500 (1s/h) VDC 17.8M RM min RM max 0 47 0 184 50 mA DC 12 .. 24 V 50+IS mA 6.5 kV U HT+ + U HT- 4.2 k VDC UHT+ - U HT- VPMAX 2.2 kV Features * Insulated plastic case recognized according to UL 94-V0 VP RP RM * Included primary resistor. ISN VC IC Vd Advantages * * * * * * * Low power Excellent accuracy Very good linearity Low thermal drift Low response time High bandwidth High immunity to external interference * Low disturbance in common mode. Ve Accuracy - Dynamic performance data XG XG XG Overall Accuracy @ VPN , TA = + 25C Overall Accuracy @ VPN , TA = - 25 .. + 70C Overall Accuracy @ VPN , TA = - 40 .. + 85C Linearity @ TA = 25C Offset current @ VP = 0, TA = 25C Response time @ 10 % of VPN Frequency bandwidth (- 3 dB) 0.7 1.5 1.7 < 0.1 0.15 < 12 DC .. 13 % % % % mA s kHz Applications * AC variable speed drives and servo motor drives L IO tr f * Static converters for DC motor drives * Battery supplied applications * Uninterruptible Power Supplies (UPS) General data TA TS m Ambient operating temperature Ambient storage temperature Mass Standards - 40 .. + 85 C - 50 .. + 90 C 375 g EN 50155 (01.12.02) EN 50124-1 (01.03.01) NFF16101/2 (01.10.88) * Power supplies for welding applications . Note : 1) Up to 2200 Vpk, 500 ms every 60 minutes & 2600 Vpk, 500 ms,12 times/year. 030805/2 LEM Components Dimensions AV 100-2000 (in mm. 1 mm = 0.0394 inch) Front view Left view HT+ HT+ M - Secondary terminals Terminal + : Supply voltage +12 .. 24 V Terminal M : Measure Terminal - : Supply voltage - 12 .. 24V Connection AV 100-2000 Top view Mechanical characteristics * General tolerance * Transducer fastening 1 mm 2 holes 6.5 mm Distance between holes 124mm * Fastening & connection of primary 2 x M5 * Fastening & connection of secondary 3 x M5 or 3 Faston 6.35 x 0.8mm Output connections must be made with screened cables * Recommended fastening torque 2.2 Nm or 1.62 Lb - Ft. Remarks * IS is positive when VP is applied on terminal +HT. * This is a standard model. For different versions, please contact us. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. |
Price & Availability of AV100-2000
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |