![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Energy Management Compact Transducer for AC Measurements Type CVT-DIN AV1/AV4/AV5 * For AC current/voltage measurement * Field adjustment capability * For DIN-rail mounting * Degree of protection: IP 50 Product Description Compact transducer for AC current/voltage measurements with field adjustment capability. The housing is for DIN-rail mounting and ensures a degree of protection of IP 50. Ordering Key Model Range code Measurement Power supply Setpoints Rated output Calibration CVT-DIN AV5AD01X Type Selection Range code AV1: AV4: AV5: 100 VAC - 1 AAC (max. 120 VAC - 1.2 A) 100 VAC - 5 AAC (max. 120 VAC - 6 A) 500 VAC - 5 AAC (max.600VAC- 6 A) Power supply A: B: C: D: 24 VAC, -15% +10%, 50/60 Hz 1) 48 VAC, -15% +10%, 50/60 Hz 1) 115 VAC, -15% +10%, 50/60 Hz 1) 230 VAC, -15% +10%, 50/60 Hz (standard) Rated output 1: 2: 3: 4: Analogue output 0 to 20 mA (standard) Analogue output 4 to 20 mADC 1) Analogue output 0 to 10 VDC 1) Analogue output 0 to 1 VDC 1) Calibration X: Y: Standard calibration Special calibration, use "Y" followed by requested value 1) On request Input Specifications Accuracy (@ 25C 5C, R.H. 60%) Additional errors: Humidity Input frequency Magnetic field Ripple Rated input AV1: AV4: AV5: 0.5% f.s., (0.1 ln/Un to 1 In/Un) The given accuracy already includes: frequency, power supply, output load influences < 0.3%, 60% to 90% R.H. < 0.4%, 62 to 400 Hz < 0.5%, @ 400 A/m 1% according to IEC 60688-1 and EN 60688-1 1 A (1 V internal shunt/1 imp)/ 100 VAC (200 k impedance) 5 A (250 mV internal shunt/ 0,05 impedance) / 100 VAC (200 k imp.) 5 A (250 mV internal shunt/ 0,05 impedance) / 500 VAC (1 M imp.) AC frequency range Overload protection Cont.: Current: Voltage: For 1 s: Current: Voltage: 48 to 62 Hz 1.2 x rated input 1.2 x rated input 20 x rated input 2 x rated input Specifications are subject to change without notice 1 CVT-DIN AV1/AV4/AV5 General Specifications Warm-up time Operating temperature Storage temperature Insulation reference voltage Insulation 15 minutes 0 to 50C (32 to 122F) (R.H. < 90% non-condensing) -10 to 60C (14 to 140F) (R.H. < 90% non-condensing) 300 Vrms to ground 2000 Vrms between output and measuring input, output and supply input. 4000 Vrms between input/output and ground 4000 Vrms for 1 minute 80 dB, 48 to 62 Hz EN 50081-1, EN 50082-1 Safety standards Safety requirements Product requirements Connector Housing Dimensions Material Degree of protection Weight Approval IEC 601010-1, EN 61010-1 IEC 60688-1, EN 60688-1 Screw-type, max. 2.5 mm2 wires 4-DIN modules, 58.5 x 89 x 71.5 mm ABS, self-extinguishing: UL 94 V-0 IP 50 300 g approx. (packing included) CE Dielectric strength Noise rejection CMRR EMC Output Specifications Range/load 0 to 20 mA 4 to 20 mA 0 to 10 V 0 to 1 V Adjustment Load: 500 Load: 500 Load: 10 k Load: 10 k Easy field adjustment from 50 to 130% of the I/U inputs which can be modified without any calibrator being requested 300 ms typical 200 ppm/C Supply Specifications AC supply 230 VAC, -15% +10%, 50/60 Hz (standard) 24 VAC, 48 VAC, 115 VAC, -15% +10%, 50/60 Hz (on request) 5 VA Power consumption Response time Temperature drift Dimensions Connections 230VAC 115VAC 48VAC 24VAC ~ ~ 1 3 CVT-DIN A-V AC/DC 4 56 8 10 11 12 Note Measurement inputs Current measurement: between current input and common (1) terminals; Voltage measurement: between voltage input and common (1) terminals. 2 Specifications are subject to change without notice + OUTPUT: 10V/1V..... - ADJUSTMENT INPUT: current (1) COM. INPUT: voltage OUTPUT: 20mA + .. - } } |
Price & Availability of CVT-DINAV5DD04Y
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |