![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Product Data Sheet 300 WATT DC/DC POWER SUPPLY DNX301 FEATURES Fully Isolated Outputs Low Profile: 9" x 4.85" x 2.00" One, Two, Three and Four Output Models N+1 Current Sharing Optional Fan Mounted On Cover Active Inrush Current Limiting DESCRIPTION The DNX301 is a compact 300 watt, multiple output power supply. All outputs are fully isolated and regulated. Active current sharing circuitry on Output #1, together with control functions and alarm options, simplifies N+1 and redundant applications. Fan and disk drive applications are handled by the peak current ratings of the auxiliary outputs. AGENCY APPROVALS See "Safety" section on page 2 for more information Website: http://www.cdpowerelectronics.com Power Electronics Division, United States 3400 E Britannia Drive, Tucson, Arizona 85706 Tel: 800.547.2537 Fax: 520.295.4197 C&D Technologies, (NCL) Milton Keynes MK14 5BU UK Tel: +44 (0)1908 615232 Fax: +44 (0)1908 617545 Any data, prices, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc. without notice. While such information is believed to be accurate as indicated herein, C&D Technologies, Inc. makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or completeness of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, C&D Technologies, Inc. hereby disclaims all warranties, either express or implied, concerning the fitness or suitability of such product(s) for any particular use or in any specific application or arising from any course of dealing or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user's intended purpose and in user's specific application. C&D Technologies, Inc. does not warrant or recommend that any of its products be used in any life support or aviation or aerospace applications. DNX301 4/2002 REV B Page 1 Input Specifications Parameter Operating Range Inrush Current Limiting 36VD 72VDC Efficiency 48 VDC, at full load 70 25 50 APK APK % Conditions DC Min 36 Typ 48 Max 72 Units VDC Remote Sense Remote Sense is provided on Output #1 and will compensate for 0.7V of line drop. Remote Sense leads are protected against open, short and reversal. Remote On/Off (Optional) The power supply is turned on with a TTL logic `1' (or open) signal and turned off by a switch closure or TTL logic `0' referenced to (-) sense terminal. Consult the factory for other options. Over Voltage Protection Output #1: 6.5V 0.5 VDC. The power supply will latch off until AC power is cycled. Over Current Protection Individual current limit on all outputs. Automatic recovery upon fault removal. Active Inrush Current Limiting Inrush current is independent of ambient temperature. Transient Response The peak output voltage excursion will not exceed 2% and will recover within 1% in 200 sec for a 25% load step change. Over Temperature Protection Thermal switch turns off power supply if overheating occurs and automatically restarts. Safety Safety certified to UL/CUL to 1950, File Number E131694 TUV to EN60950/IEC950. Cooling The unit is designed to operate with 30 CFM of airflow. Page 2 DNX301 4/2002 REV B Output Voltages and Maximum Rated Loads OUTPUT #1 VOUT IMAX 5V 5V 5V 5V 5V 5V 5V 5V 45A 45A 45A 45A 45A 45A 45A 45A MODEL NUMBER DNX301-U3A DNX301-U3B DNX301-U4C DNX301-U4D DNX301-U4E DNX301-U4F DNX301-U4G DNX301-U4H OUTPUT #2 VNOM IMAX/IPK 12V 15V 12V 12V 12V 15V 15V 15V 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A OUTPUT #3 VNOM IMAX/IPK 12V 15V 12V 12V 12V 15V 15V 15V 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A OUTPUT #4 VNOM IMAX 5V 24V 12V 5V 24V 12V 3.0A 1.5A 3.0A 3.0A 1.5A 3.0A Note: Maximum current ratings are for 10sec maximum. Total power not to exceed 300 watts. Output Specifications Parameter Regulation Line Load Cross Minimum Load Output #1 Auxiliary Outputs 3.0A 0.1A 0.03% 0.25% 0.05% Limits Parameter Voltage Adustment Range PARD Temperature Operating Storage Temperature Coefficient (TC) Conditions 20 MHz bandwidth Min Typ 5 Max 1 Units % % P-P 0 -20 After half hour warm-up 0.02 50 +85 C C %/C DNX301 4/2002 REV B Page 3 Mechanical TOP VIEW 0.25 0.55 8.50 1.95 0.040 COVER 1 TB2 3.90 4.85 1 J9 1 OUTPUT NO. 1 5V RETURN TB1 9.00 5V 6-32 THD 4 PLC'S Maximum depth of mounting scres is 0.156 inches NOTES: All measurements are in inches FAN MOUNTED ON COVER ADDS 1.30". COOLING: The DNX301 is designed to operate with 30 CM airflow. SHOCK AND VIBRATION: The DNX301 meets the requirements of MIL STD-810D. WEIGHT: Approximately 3 lbs. Terminal Block 1 POS 1 2 3 FUNCTION DC + DC Ground Terminal Block 2 POS 1 2 3 4 5 6 FUNCTION -V2 +V2 -V3 +V3 -V4 +V4 J9 Connector Molex No. 22-28-1090 PIN 1 2 3 4 5 6 7 8 9 FUNCTION + Sense - Sense N/C N/C Start Up Sync. N/C Remote Inhibit Current Share Control Signal Rtn Page 4 DNX301 4/2002 REV B |
Price & Availability of DNX301-U4H
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |