Datasheet File OCR Text: |
KP Series with PFC 250 Watt AC-DC Converters Input voltage from 187...255 V AC 1 or 2 isolated outputs up to 56.5 V DC 4 kV AC I/O electric strength test voltage LGA * * * * Rugged electrical and mechanical design Integrated power factor correction No derating over ambient temperature range Special battery charging features Selection chart Output 1 Output 2 Input voltage Rated power Type Options Uo nom [V DC] 24 24 24 25.25...28.25 25.25...28.25 25.25...28.25 48 48 48 50.5...56.5 50.5...56.5 50.5...56.5 24 24 24 Io nom [A] 9.6 10.4 11.6 8 9 10 4.8 5.2 5.8 4 4.5 5 4.8 5.2 5.8 Uo nom [V DC] 24 24 24 Io nom [A] 4.8 5.2 5.8 Ui [V AC] 187...255 187...255 187...255 187...255 187...255 187...255 187...255 187...255 187...255 187...255 187...255 187...255 187...255 187...255 187...255 Po tot [W] 230 250 278 226 254 282 230 250 278 226 254 282 230 250 278 LKP 5662-7R LKP 5660-6R LKP 5661-5R LKP 5742-7R LKP 5740-6R LKP 5741-5R LKP 5662-7R LKP 5660-6R LKP 5661-5R LKP 5742-7R LKP 5740-6R LKP 5741-5R LKP 5662-7R LKP 5660-6R LKP 5661-5R E, D, P, T, B1 E, D, P, T, B1 E, D, P, T, B1 E, D, P, T, B1 E, D, P, T, B1 E, D, P, T, B1 E, D, P, T, B1 E, D, P, T, B1 E, D, P, T, B1 E, D, P, T, B1 E, D, P, T, B1 E, D, P, T, B1 E, D, P, T, B1 E, D, P, T, B1 E, D, P, T, B1 www.power-one.com Edition 4/04.2001 1 Cassette Style Input Input voltage AC Input frequency Power factor Inrush current limitation KP Series with PFC 187...255 V AC 50/60 Hz >95% per IEC/EN 61000-3-2 by thermistor Output Efficiency Output voltage setting accuracy Output voltage switching noise Line regulation Load regulation Minimum load Current limitation Operation in parallel Hold-up time Ui nom, Io nom Ui nom, Io nom IEC/EN 61204, total Ui min...Ui max, Io nom Ui nom, 0.1...Io nom, symmetrical output load not required foldback U/I characteristic by current limitation Ui nom, Io nom up to 86% 0.6% Uo nom typ. 0.6% Uo nom typ. 0.1% Uo nom typ. 0.4% 0A typ. 110...100% Io nom 9 ms Control and protection Input fuse Input undervoltage lockout Input overvoltage lockout Input transient protection Output Output overvoltage Overtemperature Output voltage adjustment Inhibit Status indication not user accessible 4 AT typ. 80% Ui min typ. 115% Ui max varistor no-load, overload and short circuit proof suppressor diode in each output switch-off with auto restart TTL input, output(s) disabled if open circuit LEDs: OK, inhibit, overload typ. 130% Uo nom TC typ. 100C 0...110% Uo nom Safety Approvals Class of equipment Protection degree Electric strength test voltage EN 60950, UL 1950, CSA 22.2 No. 950 class I IP 30 2 kV AC 4 kV AC 1 kV AC 0.1 kV AC I/case I/O O/case O/O EMC Electrostatic discharge Electromagnetic field Electr. fast transients/bursts Surge Conducted disturbances Electromagnetic emissions IEC/EN 61000-4-2, level 4 (8/15 kV) IEC/EN 61000-4-3, level 3 (10 V/m) IEC/EN 61000-4-4, level 4 (2/4 kV) IEC/EN 61000-4-5, level 3 (2 kV) IEC/EN 61000-4-6, level 3 (10 V) CISPR 22/EN 55022 criterion A criterion A criterion A criterion B criterion A class B www.power-one.com Edition 4/04.2001 2 KP Series with PFC Environmental 250 Watt AC-DC Converters -25...50C -25...60C -25...71C -25...90C -40...100C 56 days 0.35 mm/5 gn 100 gn 40 gn 4.9 gn rms 514'000 h Operating ambient temperature Ui nom, Io nom, convection cooled, -5 Ui nom, Io nom, convection cooled, -6 Ui nom, Io nom, convection cooled, -7 Operating case temperature TC Ui nom, Io nom Storage temperature non operational Damp heat IEC/EN 60068-2-3, 93%, 40C Vibration, sinusoidal IEC/EN 60068-2-6, 10...60/60...2000 Hz Shock IEC/EN 60068-2-27, 6 ms Bump IEC/EN 60068-2-29, 6 ms Random vibration IEC/EN 60068-2-64, 20...500 Hz MTBF MIL-HDBK-217F, GB, 40C Options Electronic inrush current limitation Output voltage adjustment 40...110% Uo nom, excludes feature R and vice versa Input and/or output undervoltage monitoring Current sharing Cooling plate E P D0...D9 T B1 Pin allocation Pin 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Vo2+ Vo2+ Vo2- Vo2- Vo1+ Vo1- R i D T N N P P LKP 5000 Output 2 Output 2 Output 2 Output 2 Output 1 Output 1 Control of Uo1 Inhibit Save data Current sharing Protective earth Neutral Neutral Phase Phase Connector type H15 30 26 22 18 14 10 S10010 6 32 28 24 20 16 12 8 4 www.power-one.com Edition 4/04.2001 3 Cassette Style Mechanical data Tolerances 0.3 mm (0.012") unless otherwise indicated. 159 (6.25") KP Series with PFC European Projection 4.5 (0.18") 7 TE 9 TE 111 (3U) (4.37") 89 (3.50") Test jacks Option P (Uo) Option D (Uto) Option D (Uti) LED i LED OK LED IoL Measuring point of case temperature TC 50 (1.97") 171.93 (6.77") (DIN 41494) 168.5 (6.63") S09002 6.5 (0.26") 80 (3.15") Accessories Front panels 19" (Schroff/Intermas) Mating H15 connectors with screw, solder, fast-on or press-fit terminals Connector retention facilities and code key system for connector coding Chassis or wall mounting plates for frontal access Universal mounting brackets for chassis or DIN-rail mounting Temperature sensor for battery charger www.power-one.com Edition 4/04.2001 4 |
Price & Availability of LKP5742-7R
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |