![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Voltage Transducer LV 100 For the electronic measurement of voltages : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high voltage) and the secondary circuit (electronic circuit). IPN = 10 mA VPN = 100 .. 2500 V Electrical data IPN IP RM Primary nominal r.m.s. current Primary current, measuring range Measuring resistance with 15 V ISN KN VC IC Vd @ 10 mA @ 20 mA max max 10 mA 0 .. 20 mA RM min RM max 0 0 150 50 mA V mA kV Features *Closed loop (compensated) voltage transducer using the Hall effect *Insulated plastic case recognized according to UL 94-V0. Secondary nominal r.m.s. current Conversion ratio Supply voltage ( 5 %) Current consumption R.m.s. voltage for AC isolation test 1), 50 Hz, 1 mn 50 10000 : 2000 15 10 + IS 6 Principle of use *For voltage measurements, a current proportional to the measured voltage must be passed through an external resistor R 1 which is selected by the user and installed in series with the primary circuit of the transducer. Accuracy - Dynamic performance data XG L Overall Accuracy @ IPN , TA = 25C Linearity Offset current @ IP = 0, TA = 25C Thermal drift of IO Response time 2) @ 90 % of VP max 0.7 < 0.1 Typ Max 0.2 0.3 % % mA mA s Advantages *Excellent accuracy *Very good linearity *Low thermal drift *Low response time *High bandwidth *High immunity to external interference IO IOT tr 0C .. + 70C 0.2 20 .. 100 General data TA TS RP RS m Ambient operating temperature Ambient storage temperature Primary coil resistance @ TA = 70C Secondary coil resistance @ TA = 70C Mass Standards 3) 0 .. + 70 - 25 .. + 85 1900 60 460 EN 50178 C C g *Low disturbance in common mode. Applications *AC variable speed drives and servo motor drives *Static converters for DC motor drives *Battery supplied applications *Uninterruptible Power Supplies (UPS) *Power supplies for welding applications. Notes : 1) 2) 3) Between primary and secondary R 1 = 100 k (L/R constant, produced by the resistance and inductance of the primary circuit) A list of corresponding tests is available 980709/5 LEM Components w w w .lem.com Dimensions LV 100 Front view (in mm. 1 mm = 0.0394 inch) Left view Secondary terminals Terminal + : supply voltage + 15 V Terminal M : measure Terminal - : supply voltage - 15 V Connection Top view Mechanical characteristics *General tolerance *Fastening *Connection of primary Fastening torque *Connection of secondary 0.3 mm 2 holes 6.5 mm M5 screw terminals 2.2 Nm or 1.62 Lb - Ft. Faston 6.3 x 0.8 mm Remarks *IS is positive when VP is applied on terminal +HT. *This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. Instructions for use of the voltage transducer model LV 100 Primary resistor R 1 : the transducer' optimum accuracy is obtained at the nominal primary current. As far as possible, R 1 should be s calculated so that the nominal voltage to be measured corresponds to a primary current of 10 mA. Example: Voltage to be measured VPN = 1000 V a) R 1 = 100 k /40 W, IP = 10 mA b) R 1 = 400 k / 5 W, IP = 2.5 mA Accuracy = 0.7 % of VPN (@ TA = +25C) Accuracy = 2.5 % of VPN (@ TA = +25C) Operating range (recommended) : taking into account the resistance of the primary windings (which must remain low compared to R 1, in order to keep thermal deviation as low as possible) and the isolation, this transducer is suitable for measuring nominal voltages from 100 to 2500 V. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. |
Price & Availability of LV100
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |