 TOTAL POWER INT'L
60W Single Output Switching Power Supply
Features :
Universal AC input/Full range Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 50KHz 2 years warranty
S-60
series
Protections:Short circuit/Over load/Over voltage
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT
S-60-5 S-60-12 S-60-15 S-60-24
5V 12A 0 ~ 12A 60W
12V 5A 0 ~ 5A
60W 120mVp-p
15V 4A 0 ~ 4A 60W 150mVp-p
13.5 ~ 16.5V
1.0%
0.5%
0.5%
24V 2.5A 0 ~ 2.5A 60W 150mVp-p
21.6 ~ 26.4V
1.0%
0.5%
0.5%
RIPPLE & NOISE (max.) Note.2 120mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% LINE REGULATION 0.5%
10.8 ~ 13.2V 1.0%
0.5%
0.5%
LOAD REGULATION SETUP, RISE, HOLD TIME VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY(Typ.) AC CURRENT INRUSH CURRENT(max.) LEAKAGE CURRENT OVER LOAD
PROTECTION
1.0% 300ms, 50ms, 80ms / 230VAC
800ms, 50ms, 10ms / 115VAC at full load
85 ~ 264VAC 47 ~ 63Hz 73%
120 ~ 370VDC 76% 60A/230VAC 77% 79%
2A/115VAC 1A/230VAC COLD START 30A/115VAC <3.5mA / 240VAC
105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed. 5.75 ~ 6.75V -10 ~ +60 13.8 ~ 16.2V 17.25 ~ 20.25 27.6 ~ 32.4V Protection type : Hiccup mode, recovers automatically after fault condition is removed. (Refer to output load derating curve)
20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1012, UL1950, TUV EN60950 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
OVER VOLTAGE
WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE EMC
(Note 4)
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
MTBF OTHERS DIMENSION PACKING
NOTE
316.2K hrs min. MIL-HDBK-217F (25 159*97*38mm (L*W*H)
0.51Kg; 24pcs/13.1Kg/0.7CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
60W Single Output Switching Power Supply
Mechanical Specification
S-60
Case No. 901
series
Unit:mm
152.5
1
9.5
2 3 4
65
3.5
84.5
2 -M 3
78
7
8.2
5
3 .5
4.5
24
159
6.5
150
9
18.5
9
22
117
Terminal Pin. No Assignment
Pin No. 1 2 3 Assignment AC/L AC/N FG Pin No. 4 5 Assignment DC OUTPUT -V DC OUTPUT +V
Output Derating
Static Characteristics (24V)
Vo 32 28
28.5
M3
18
38
3-
3.5
97
3 .5
Ta=25
350 300 250 200 150 100 50
100
80
OUTPUT VOLTAGE (V)
24 20 16 12 8
60
40
20
-10 -10
0 0
10
20
30
40
50 45
60 55
(VERTICAL) (HORIZONTAL)
60
80
100
120
140
160
180
200
220
240
260
AMBIENT TEMPERATURE (
)
INPUT VOLTAGE (V) 60Hz
OUTPUT RIPPLE (mVp-p)
LOAD (%)


▲Up To Search▲   

 