![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TOTAL POWER INT'L 60W Single Output Switching Power Supply Features : Universal AC input/Full range Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 50KHz 2 years warranty S-60 series Protections:Short circuit/Over load/Over voltage SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT S-60-5 S-60-12 S-60-15 S-60-24 5V 12A 0 ~ 12A 60W 12V 5A 0 ~ 5A 60W 120mVp-p 15V 4A 0 ~ 4A 60W 150mVp-p 13.5 ~ 16.5V 1.0% 0.5% 0.5% 24V 2.5A 0 ~ 2.5A 60W 150mVp-p 21.6 ~ 26.4V 1.0% 0.5% 0.5% RIPPLE & NOISE (max.) Note.2 120mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% LINE REGULATION 0.5% 10.8 ~ 13.2V 1.0% 0.5% 0.5% LOAD REGULATION SETUP, RISE, HOLD TIME VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY(Typ.) AC CURRENT INRUSH CURRENT(max.) LEAKAGE CURRENT OVER LOAD PROTECTION 1.0% 300ms, 50ms, 80ms / 230VAC 800ms, 50ms, 10ms / 115VAC at full load 85 ~ 264VAC 47 ~ 63Hz 73% 120 ~ 370VDC 76% 60A/230VAC 77% 79% 2A/115VAC 1A/230VAC COLD START 30A/115VAC <3.5mA / 240VAC 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed. 5.75 ~ 6.75V -10 ~ +60 13.8 ~ 16.2V 17.25 ~ 20.25 27.6 ~ 32.4V Protection type : Hiccup mode, recovers automatically after fault condition is removed. (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1012, UL1950, TUV EN60950 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC (Note 4) I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A MTBF OTHERS DIMENSION PACKING NOTE 316.2K hrs min. MIL-HDBK-217F (25 159*97*38mm (L*W*H) 0.51Kg; 24pcs/13.1Kg/0.7CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 60W Single Output Switching Power Supply Mechanical Specification S-60 Case No. 901 series Unit:mm 152.5 1 9.5 2 3 4 65 3.5 84.5 2 -M 3 78 7 8.2 5 3 .5 4.5 24 159 6.5 150 9 18.5 9 22 117 Terminal Pin. No Assignment Pin No. 1 2 3 Assignment AC/L AC/N FG Pin No. 4 5 Assignment DC OUTPUT -V DC OUTPUT +V Output Derating Static Characteristics (24V) Vo 32 28 28.5 M3 18 38 3- 3.5 97 3 .5 Ta=25 350 300 250 200 150 100 50 100 80 OUTPUT VOLTAGE (V) 24 20 16 12 8 60 40 20 -10 -10 0 0 10 20 30 40 50 45 60 55 (VERTICAL) (HORIZONTAL) 60 80 100 120 140 160 180 200 220 240 260 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz OUTPUT RIPPLE (mVp-p) LOAD (%) |
Price & Availability of S-60-5
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |