![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
version 2.0 - 01/98 ______________________________________________________________________________________________________ TFS101.doc VI TELEFILTER SAW-Filter Specification TFS 101 - 1/4 ______________________________________________________________________________________________________ Measurement Condition Ambient Temperature: 23 C Input Power Level: 10 dBm Terminating Impedances 1.3k // -2pF Characteristics Remark: Reference level for the relative attenuation arel is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The nominal frequency fN is fixed on 101,255 MHz. Data ______________________________________________________________________________________________________ Input Power Level max. 10 dBm ______________________________________________________________________________________________________ Insertion Loss ae = amin max. 5 dB (Reference Level) ______________________________________________________________________________________________________ Nominal Frequency 101,255 MHz fN ______________________________________________________________________________________________________ Amplitude Ripple in Pass Band fN ... fN 10 kHz max. 0,5 dB ______________________________________________________________________________________________________ Relative Attenuation arel fN 10 kHz ... fN 20 kHz max. 2 dB kHz ... fN 25 kHz max. 3 dB fN 20 kHz ... fN 80 kHz min. 5 dB fN 55 kHz ... fN 100 kHz min. 23 dB fN 80 kHz ... fN 200 kHz min. 28 dB fN 100 kHz ... fN + 400 kHz min. 50 dB fN + 200 kHz ... fN - 895 kHz min. 50 dB fN - 200 kHz ... fN - 925 kHz min. 70 dB fN - 895 ______________________________________________________________________________________________________ Intermodulation Input Frequency I.M. typ. Value Variation/ Limitation + 100 kHz, + 200 kHz - 100 kHz, - 200 kHz Input Level - 30 dBm I.M. Products max.- 110 dBm ______________________________________________________________________________________________________ GDD Group Delay Distortion fN ... fN 15 kHz max. 5 s ______________________________________________________________________________________________________ F1 F2 Operating Temperature Range - 25 C ... + 75 C Storage Temperature Range - 40 C ... + 85 C ______________________________________________________________________________________________________ Temperature Coefficient - 0,036 ppm/K TC ______________________________________________________________________________________________________ Frequency Inversion Temperature 25 C ______________________________________________________________________________________________________ Generated: Checked / Approved: ______________________________________________________________________________________________________ VI TELEFILTER / Potsdamer Strae 18 / D 14 513 TELTOW Phone: (+33 28) 47 84 52 / Fax: (+33 28) 47 84 30 / E-Mail: tft@telefilter.com TFS101.doc version 2.0 - 01/98 ______________________________________________________________________________________________________ VI TELEFILTER SAW-Filter Specification TFS 101 - 2/4 ______________________________________________________________________________________________________ Construction, Pin Connection and 50 Matching Network (All Dimensions in mm) TFS 101 tft H9 ______________________________________________________________________________________________________ VI TELEFILTER / Potsdamer Strae 18 / D 14 513 TELTOW Phone: (+33 28) 47 84 52 / Fax: (+33 28) 47 84 30 / E-Mail: tft@telefilter.com TFS101.doc version 2.0 - 01/98 ______________________________________________________________________________________________________ VI TELEFILTER SAW-Filter Specification TFS 101 - 3/4 ______________________________________________________________________________________________________ Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 30g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,075 mm or 1g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 90 % to 95 % rel. humidity, 40 C, 10 days; DIN IEC 68 - 2 - 3 2. Vibration: 3. Damp heat: (steady state) 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on sheet 4; Packing Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 1700 Tape (all dimensions in mm) W Po Do D1 E F : : : : : : 24 0,3 4 0,1 1,5 + 0,5 1,5 + 0,5 1,75 0,1 11,5 0,1 0,75 2 0,1 12 0,1 1,5 7,1 0,2 13,9 0,2 COVER TAPE EMBOSSED CARRIER TAPE Do Po P2 E Ao F W D1 21,4 0,1 G (min) : P2 : P1 : D1(min) : Ao : Bo : Bo G P1 W2 Reel (all dimensions in mm): A W1 W2 (max) : N (min) C : : : : 330 24,4 +2 30,4 >= 90 C A N 13 0,25 W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. ______________________________________________________________________________________________________ VI TELEFILTER / Potsdamer Strae 18 / D 14 513 TELTOW Phone: (+33 28) 47 84 52 / Fax: (+33 28) 47 84 30 / E-Mail: tft@telefilter.com TFS101.doc version 2.0 - 01/98 ______________________________________________________________________________________________________ VI TELEFILTER SAW-Filter Specification TFS 101 - 4/4 ______________________________________________________________________________________________________ Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Chip-mount air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 ______________________________________________________________________________________________________ VI TELEFILTER / Potsdamer Strae 18 / D 14 513 TELTOW Phone: (+33 28) 47 84 52 / Fax: (+33 28) 47 84 30 / E-Mail: tft@telefilter.com |
Price & Availability of TFS101
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |