|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TFS70H12.doc Version 2.0 19.02.2001 VI TELEFILTER 1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc: Filter Specification TFS 70H12 - 1/4 25 C. 0 dBm. for input: for output: 50 0 pF. 50 0 pF. 2. Characteristics : Remark: Reference level for the relative attenuation arel of the TFS 70H12 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme. Data Insertion loss (Reference level) Centre frequency Pass band ( PB ) : Amplitude ripple in : Bandwidth ( BW ) : 0,8 dB - band width 1,5 dB - band width 3 dB - band width 20 25 30 40 50 dB - band width dB - band width dB - band width dB - band width dB - band width arel 3,6 MHz 3,8 MHz 4,0 MHz 5,0 5,25 9 12 9 50 50 90 145 155 210 MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz fc - 3,6 MHz ... fc + 3,6 MHz at ambient temperature TA ae typ. value 21,5 70,0 dB MHz tolerance / limit max. 23 dB MHz MHz dB fc at ambient temperature (fCTA) 70,0 0,08 fc ... fc 4,0 0,4 dB max. 0,8 7,45 7,75 8,05 9,28 9,47 9,62 9,88 10,11 MHz MHz MHz MHz MHz MHz MHz MHz min. min. min. max. max. max. 7,2 7,6 8,0 9,5 10 10,5 MHz MHz MHz MHz MHz MHz Relative attenuation fc fc fc fc fc fc fc fc fc fc fc fc fc 3,6 3,8 4,75 5,0 5,25 50 12 + 9 68 + 50 + 90 + 145 + 155 fc ..... fc MHz ..... fc MHz ..... fc MHz ..... fc MHz ..... fc MHz ..... fc MHz ..... fc MHz ..... fc MHz ..... fc + MHz ..... fc MHz ..... fc + MHz ..... fc + MHz ..... fc + MHz ..... fc + 27 45 54 55...60 45...50 55...60 45...50 45...55 55...58 0 55...60 dB dB dB dB dB dB dB dB dB dB dB max. max. max. min. min. min. min. min. min. 0,8 1,5 3 25 40 50 45 40 45 dB dB dB dB dB dB dB dB dB Group delay ( mean value in PB ): Group delay ripple in PB (p-p): Deviation from linear phase in PB : Triple transit attenuation compared to main signal Crosstalk Temperature coefficient of frequency ( Tcf ) : Frequency deviation of fc over temperature : Operating temperature range Storage temperature range Generated: 2,09 s 55...65 ns 3 (r.m.s. 0,8 ) 50...52 70...75 dB dB max. max. max. 2,5 90 4 s ns -87 ppm/K fc(Hz) = Tcf(ppm/K) x (T - To) x fCTA (MHz) - 25 C ... + 80 C - 40 C ... + 85 C Wadim Dunzow Checked/Approved: Dr. Bert Wall VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS70H12.doc Version 2.0 19.02.2001 VI TELEFILTER Filter Specification TFS 70H12 - 2/4 3. Package and pin connection : (All dimensions in mm) 22,5 Max. 5,0 max. 5,6 max. 2,54 0,2 6x2,54 = 15,62 13 max. 0,45 Dia. 7,62 TFS 70H12 tft N05 1 2 7 Pin Pin Pin Pin Pin 14 9 8 Date-code: L M N ....... Year+week 1999 2000 2001 ....... 14 1 8 7 2, 9 Input Input RF Return Output Output RF Return Pakage Ground 4. 50 matching network : 14 9 TFS 70H12 tft N05 8 12 7 VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS70H12.doc Version 2.0 19.02.2001 VI TELEFILTER 5. Air reflow temperature conditions : Filter Specification TFS 70H12 - 3/4 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS70H12.doc Version 2.0 19.02.2001 VI TELEFILTER History Version 1.0 1.1 Reason of changes Generate Filter Specification . Filter Specification TFS 70H12 - 4/4 Name Dunzow W. Dunzow W. Date 25.07.2000. 19.02.2001 Change the following parameters according to customer requirements - add band width 1,5 dB : min. 7,6 MHz; VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information |
Price & Availability of TFS70H12 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |