Part Number Hot Search : 
FM305 74LV107 74HCT4 SS2150 746EP SG2846Q A0B41Z D1A12000
Product Description
Full Text Search
 

To Download TFS942 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 TFS942.doc
version 1.2
19.11.2003
VI TELEFILTER
Measurement condition
Ambient temperature: Input power level: Terminating impedance: Input: Output: 25 2 0 50 50
Development Specification
TFS 942
1/5
C dBm
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 942,5 MHz without any tolerance or limit. The electrical data have to be guaranteed at ambient temperature.
Data
Insertion loss Nominal frequency Passband Pass band ripple (p-p) Absolute attenuation 0 860 880 905 970,7 980 1005 1050 1500 MHz MHz MHz MHz MHz MHz MHz MHz MHz ... ... ... ... ... ... ... ... ... 860 880 905 915 980 1005 1050 1500 3000 MHz MHz MHz MHz MHz MHz MHz MHz MHz OTR Aabs Ae fN PB
typ. value
TCf * -30 ppm/K
tolerance / limit
max. 3,4 942,5 fN max. 17,5 1,7 dB MHz MHz dB
min. min. min. min. min. min. min. min. min.
40 35 22 20 14 18 30 40 15
dB dB dB dB dB dB dB dB dB
Operable temperature range Storage temperature range Temperature coefficient of frequency Input power level *) fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).
- 20 C ... + 75 C - 40 C ... + 85 C max. 15 dBm
Generated
:
Checked / approved
:
TELE FILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS942.doc
version 1.2
19.11.2003
VI TELEFILTER
Construction and pin configuration
(All dimensions in mm)
Development Specification
TFS 942
2/5
942 R42 R39 date code
Date code: Year+week N P R 2001 2002 2003 ...
Pin Pin Pin Pin Pin Pin
1 2 3 4 5 6
Input Ground Input Ground Output Ground Output Ground
TELE FILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS942.doc
version 1.2
19.11.2003
VI TELEFILTER
Stability Characteristics
Development Specification
TFS 942
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N
2. Vibration:
3. Change of temperature: 4. Resistance to solder heat (reflow):
reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4
Packing
Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 9000 min 300 mm min 500 mm min 300 mm
EMBOSSED CARRIER TAPE
Tape (all dimensions in mm)
W Po Do E F G (min) P2 P1 D1(min) Ao Bo CT : : : : : : : : : : : : 8 4 1,5 1,75 3,5 0,75 2 4 1,5 3,25 3,25 5,5 0,3 0,1 + 0,1 0,1 0,05
CT Do Po P2
E Ao F W
D1 Bo
0,05 0,1
G
0,1 0,1 0,2
P1
COVER TAPE
W2
Reel (all dimensions in mm): A W1 : : 330 8,4 + 2,0 14,4 : : 50 13 +0,5/ -0,2
A C N
W2 (m ax) : N (m in) C
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
TELE FILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS942.doc
version 1.2
19.11.2003
VI TELEFILTER
Air reflow temperature conditions
Development Specification
TFS 942
4/5
1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods main-heating periods 150 C - 170 C over 200 C 60 sec. - 90 sec. 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / s ec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
TELE FILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS942.doc
version 1.2
19.11.2003
VI TELEFILTER
History
Version 1.0 1.1 1.2 Reason of Changes
Development Specification
TFS 942
5/5
Name Roizengaft Roizengaft Wall
Date 16.10.2003 30.10.2003 19.11.2003
- Generation of development specification - Definition of packing Change operating temperature range to operable temperature range Change remark for electrical data Change ambient temperature Add value for temperature coefficient of frequency
TELE FILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS942

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X