 10.0-18.0 GHz GaAs Transmitter QFN, 7x7mm
August 2007 - Rev 19-Aug-07
U1005-QD
Features
Integrated Mixer, LO Buffer and Output Amplifier 8 dB Conversion Gain 15 dB Image Rejection +11 dBm P1dB +6 dBm LO Drive Level -12 dBm LO Leakage Power
Mimix Broadband's 10.0-18.0 GHz GaAs MMIC transmitter provides +11 dBm output P1dB compression and 15 dB image rejection across the band. This device is an image reject, balanced mixer followed by a two stage output amplifier. The image reject mixer reduces the need for unwanted sideband filtering before the power amplifier. I and Q mixer inputs are provided and an external 90 degree hybrid is required to select the desired sideband. This device comes in a 7x7mm QFN surface mount laminate package which is RoHS compliant. This device is well suited for Millimeter-wave Point-to-Point Radio, LMDS, SATCOM and VSAT applications.
General Description
Absolute Maximum Ratings
Supply Voltage (Vd) Supply Current (Id1,2,3) Gate Bias Voltage (Vg) Input Power (IF Pin) Storage Temperature (Tstg) Operating Temperature (Ta) Channel Temperature (Tch)
+6.0 VDC 250,400 mA +0.3 VDC 0.0 dBm -65 to +165 OC -55 to MTTF Table 1 MTTF Table 1
(1) Channel temperature affects a device's MTTF. It is recommended to keep channel temperature as low as possible for maximum life.
Electrical Characteristics (Ambient Temperature T = 25o C)
Parameter Frequency Range (RF) Upper Side Band Frequency Range (LO) Frequency Range (IF) Output Return Loss RF (S22) Small Signal Conversion Gain IF/RF (S21) LO Input Drive (PLO) LO Leakage at RF (LO/RF) Output P1dB Compression (P1dB) Output Third Order Intercept (OIP3) Drain Bias Voltage (Vd1,2) Source Bias Voltage (Vs1) Gate Bias Voltage (Vg1), Mixer Gate Bias Voltage (Vg2) Supply Current (Id1) (Vd1=5.0V) Supply Current (Id2) (Vd2=5.0V, Vg=-0.1V Typical) Supply Current (Is1) (Vs1=-5.0V)
Units GHz GHz GHz dB dB dBm dBm dBm dBm VDC VDC VDC VDC mA mA mA Min. 10.0 7.0 DC +4.0 -1.2 Typ. 18.0 10.0 +6.0 -18.0 11.0 TBD +5.0 -5.0 -0.6 -0.1 140 210 140
Max. 18.0 21.0 3.0 +5.5 +0.1 200 300 200
Page 1 of 6
Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099 Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com
Characteristic Data and Specifications are subject to change without notice. (c)2007 Mimix Broadband, Inc. Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept their obligation to be compliant with U.S. Export Laws.
10.0-18.0 GHz GaAs Transmitter QFN, 7x7mm
August 2007 - Rev 19-Aug-07
U1005-QD
Transmitter Measurements
XU1005-QD, Conversion Gain (dB) 20.0 18.0 16.0 Conversion Gain (dB) 14.0 12.0 10.0 8.0 6.0 4.0 2.0 0.0 10 11 12 13 14 15 16 17 18 RF (GHz) [IF=2GHz] -60.0 10 11 12 13 14 15 16 17 18 RF (GHz) [IF=2GHz] USB LSB Image Rejection (dBc) 0.0 -10.0 -20.0 -30.0 -40.0 -50.0 USB LSB XU1005-QD, Image Rejection (dBc)
XU1005-QD, P1dB Compression (dBm) 20.0 18.0 16.0 14.0 P1dB (dBm) 12.0 10.0 8.0 6.0 4.0 2.0 0.0 10 11 12 13 14 15 16 17 18 RF (GHz) [IF=2GHz] -70.0 -80.0 8 USB LSB LO Leakage (dBm) 0.0 -10.0 -20.0 -30.0 -40.0 -50.0 -60.0
XU1005-QD, LO Leakage at RF (dBm), LO = +4 dBm
X1LO X2LO X3LO
13
18
23
28 LO (GHz)
33
38
43
48
Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099 Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com
Page 2 of 6
Characteristic Data and Specifications are subject to change without notice. (c)2007 Mimix Broadband, Inc. Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept their obligation to be compliant with U.S. Export Laws.
10.0-18.0 GHz GaAs Transmitter QFN, 7x7mm
August 2007 - Rev 19-Aug-07
U1005-QD
Physical Dimensions
(Note: Engineering designator is 14TX0614)
Pin Table
Pin Number 1-5 6 7-12 13 14-17 18 19 20 21-27 28 29-35 36 37 38 39-40 41 42 43 44 Nominal Value Pin Function Pin Name Not Connected NC LO Input LO Not Connected NC -0.6 Mixer Gate Bias VG1 Not Connected NC IF2 Input IF2 Not Connected NC +5.0, 210 Drain Bias VD2 Not Connected NC RF Output RF Out Not Connected NC -0.1 RF Amp Gate Bias VG2 Not Connected NC IF1 Input IF1 Not Connected NC Drain Bias +5.0, 140 VD1 Not Connected NC VS1 Bias -5.0 VS1 Not Connected NC Units
Volts
Volts, mA
Volts
Volts, mA Volts
Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099 Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com
Page 3 of 6
Characteristic Data and Specifications are subject to change without notice. (c)2007 Mimix Broadband, Inc. Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept their obligation to be compliant with U.S. Export Laws.
10.0-18.0 GHz GaAs Transmitter QFN, 7x7mm
August 2007 - Rev 19-Aug-07
U1005-QD
Application Layout
Application Layout Pin Designations
Pin Name GND LO IN GND VG1 IF2 IN VD2 GND RF Out GND VG2 IF1 IN VD1 VS1 NC Pin Function Ground LO Input Ground Mixer gate Voltage IF2 Input RF Amp Drain Voltage Ground RF output Ground RF Amp Gate Voltage IF1 Input LO Amp Drain Voltage LO Amp Bias Voltage Not Connected Nominal Value 7 to 21 -0.6 DC to 3 5 10 to 18 -0.1 DC to 3 5 -5 Unit GHz Volt GHz Volt GHz Volt GHz Volt Volt
Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099 Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com
Page 4 of 6
Characteristic Data and Specifications are subject to change without notice. (c)2007 Mimix Broadband, Inc. Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept their obligation to be compliant with U.S. Export Laws.
10.0-18.0 GHz GaAs Transmitter QFN, 7x7mm
August 2007 - Rev 19-Aug-07
U1005-QD
App Note [1] Biasing - This device is operated by separately biasing Vd(1,2)=5.0V, Vss=-5.0V, Id1=140mA, Id2=210mA and Is1=140mA. Additionally, a mixer is also required with Vg1=-0.6V. Adjusting Vg1 above or below this value can adversely affect conversion gain, LO/RF isolation and intercept point performance. Gain control can be adjusted by varying Vg2 from 0.0 to -1.2 V with 0.0V providing minimum attenuation and -1.2 V providing maximum attenuation. It is also recommended to use active biasing to keep the currents constant as the RF power and temperature vary; this gives the most reproducible results. Depending on the supply voltage available and the power dissipation constraints, the bias circuit may be a single transistor or a low power operational amplifier, with a low value resistor in series with the drain supply used to sense the current. The gate of the pHEMT is controlled to maintain correct drain current and thus drain voltage. The typical gate voltage needed to do this is -0.2V. Typically the gate is protected with Silicon diodes to limit the applied voltage. Also, make sure to sequence the applied voltage to ensure negative gate bias is available before applying the positive drain supply.
MTTF Tables (TBD)
These numbers were calculated based on accelerated life test information and thermal model analysis received from the fabricating foundry.
Backplate Temperature 55 deg Celsius 75 deg Celsius 95 deg Celsius
Channel Temperature deg Celsius deg Celsius deg Celsius
Rth
MTTF Hours
FITs
C/W C/W C/W
E+ E+ E+
E+ E+ E+
Bias Conditions: Vd1=Vd2=5.0V, Vss=-5.0V, Id1=140mA, Id2=210mA, Id3=140mA, Is1=140mA
Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099 Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com
Page 5 of 6
Characteristic Data and Specifications are subject to change without notice. (c)2007 Mimix Broadband, Inc. Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept their obligation to be compliant with U.S. Export Laws.
10.0-18.0 GHz GaAs Transmitter QFN, 7x7mm
August 2007 - Rev 19-Aug-07
U1005-QD
CAUTION! - Mimix Broadband MMIC Products contain gallium arsenide (GaAs) which can be hazardous to the human body and the environment. For safety, observe the following procedures: Do not ingest. Do not alter the form of this product into a gas, powder, or liquid through burning, crushing, or chemical processing as these by-products are dangerous to the human body if inhaled, ingested, or swallowed. Observe government laws and company regulations when discarding this product. This product must be discarded in accordance with methods specified by applicable hazardous waste procedures. Life Support Policy - Mimix Broadband's products are not authorized for use as critical components in life support devices or systems without the express written approval of the President and General Counsel of Mimix Broadband. As used herein: (1) Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. (2) A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Package Attachment - This packaged product from Mimix Broadband is provided as a rugged surface mount package compatible with high volume solder installation. The package is a low-cost plastic package. Vacuum tools or other suitable pick and place equipment may be used to pick and place this part. Care should be taken to ensure that there are no voids or gaps in the solder connection so that good RF, DC and ground connections are maintained. Voids or gaps can eventually lead not only to RF performance degradation, but reduced reliability and life of the product due to thermal stress.
Reflow Profile Ramp Up Rate Activation Time and Temperature Time Above Melting Point Max Peak Temperature Time Within 5 C of Peak Ramp Down Rate Part Number for Ordering XU1005-QD-0N00 XU1005-QD-0N0T XU1005-QD-EV1
SnPb 3-4 C/sec 60-120 sec @ 140-160 C 60-150 sec 240 C 10-20 sec 4-6 C/sec
Pb Free 3-4 C/sec 60-180 sec @ 170-200 C 60-150 sec 265 C 10-20 sec 4-6 C/sec
Description Ni/Au plated RoHS compliant QFN 7x7 44L surface mount package in bulk quantity Ni/Au plated RoHS compliant QFN 7x7 44L surface mount package in tape and reel XU1005-QD Evaluation Module
We also offer this part with alternative plating options. Please contact your regional sales manager for more information regarding different plating types.
Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099 Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com
Page 6 of 6
Characteristic Data and Specifications are subject to change without notice. (c)2007 Mimix Broadband, Inc. Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept their obligation to be compliant with U.S. Export Laws.


▲Up To Search▲   

 
Price & Availability of XU1005-QD07

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X