![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Sensing element/Gauge Features . Dual-In-line-Package(DIP)or Horizontal pressure port, Easy to mount on PCB . Vacuum pressure measurable . Non-corrosive liquid measurable(FPMC/FHMC available) FPM,FHM Data sheet Applications . Industrial instrumentation . Pressure switch, Pneumatic device . Medical device . Turbo boost pressure measurement for Automotive system Part number for ordering FPM C - 07P G R Model FPM FHM Rated pressure (PSI) Terminal leads direction(See Outline Diagram) No mark : R: Pressure type Available pressure media G : Gauge pressure No mark : Non-corrosive gas only C : Non-corrosive gas and liquid(Contact us about availability) Gauge pressure FPM FHM Pressure type Model Package configuration Measurable pressure range(kPa) 13.79 13.79 34.47 34.47 48.26 48.26 98.07 103.4 98.07 206.8 98.07 344.7 98.07 482.6 98.07 827.4 Dual-In-line-Package(DIP) Horizontal pressure port DIP FPM-02PG FPM-05PG FPM-07PG FPM-15PG FPM-30PG FPM-50PG FPM-70PG FPM-120PG Part number for ordering FPM-02PGR FHM-02PG FPM-05PGR FHM-05PG FPM-07PGR FHM-07PG FPM-15PGR FHM-15PG FPM-30PGR FHM-30PG FPM-50PGR FHM-50PG FPM-70PGR FHM-70PG FPM-120PGR FHM-120PG FHM-02PGR FHM-05PGR FHM-07PGR FHM-15PGR FHM-30PGR FHM-50PGR FHM-70PGR FHM-120PGR Specifications Model/Rated pressure 02PG 05PG 07PG 15PG 30PG 50PG 70PG 120PG unit Recommended operating conditions Pressure type Gauge pressure 13.79 34.47 48.26 103.4 206.8 344.7 482.6 Rated pressure 0.141 0.352 0.492 1.055 2.109 3.516 4.922 13.79 34.47 48.26 98.07 98.07 98.07 98.07 Measurable pressure range 13.79 34.47 48.26 103.4 206.8 344.7 482.6 Pressure media FPM, FHM : Non-corrosive gas only, FPMC, FHMC : Non-corrosive gas and liquid Excitation current(Constant) 1.5 Absolute maximum rating Maximum load pressure Twice of rated pressure Maximum excitation current 3 Operating temperature 20 100 Storage temperature 40 120 Operating humidity 30 80(No dew condensation) Electric performances/characteristics(Excitation current I=1.5mA constant, Ambient temperature Ta=25 ) Full scale span voltage 60 140 Offset voltage 20 Bridge impedance 4000 6000 Mechanical response time 2(For the reference) Temperature sensitivity of offset(TSO) 5 Temperature coefficient of sensitivity(TCS) 2.5 Linearity 0.5 0.3 0.5 Pressure hystersis 0.4 0.2 Accuracy Please consult us available liquid pressure media when you choose the C models. 827.4 8.437 98.07 827.4 kPa kg/cm2 kPa mADC 1.5times of rated pressure mADC RH mV mV msec FS/0 50 FS/0 50 FS FS 0.6 0.4 1 Sensing element/Gauge Outline dimensions FPM,FHM Data sheet unit(mm) FPM 12 6 5 4 4 2.2 8 5 0.2 max 15 Pressure port 0.8 0.6 Vent hole 4.5 4 5 6 15.24(600mil) R1.5 3 C0.5 14 1 2 3 Terminal leads 3 2 1 Labelled faceplate 6.8 2.8 Recommended footprint for PCB 6- 0.9(Diameter of through holes) 2.54 2.54 6- 1.8(Diameter of lands) 1.2 60 15.2 unit(mm) unit(mm) FPM-R 0.2 12 max 15 4 2.2 8 5 6 5 4 0.8 Pressure port 4 5 6 R1.5 14 3 C0.5 1 2 3 Terminal leads Labelled faceplate 0.6 Vent hole 32 4.5 1 15.24(600mil) 0.5 2.54 2.54 Recommended footprint for PCB 6- 0.9(Diameter of through holes) 6- 1.8(Diameter of lands) 1.2 60 2.8 6.8 15.2 unit(mm) 2 2.54 2.54 2.54 2.54 0.5 Sensing element/Gauge Outline dimensions FPM,FHM Data sheet FHM 2.54 2.54 1 2 3 unit(mm) Pressure port 6 (14) 5 4 15 0.25 1 3.2 0.6 5.5 2.6 6 10.15 Vent hole 8 Labelled faceplate 6 5 4 1.2 3.4 7.6 Recommended footprint for PCB 6- 1(Diameter of through holes) 6- 1.8(Diameter of lands) 8 1 2 3 10 FHM-R 1 2.54 2.54 2 3 unit(mm) Pressure port 6 5 4 (14) 1.2 1 3.2 1.55 5.5 2.6 6 15 10.16 0.25 Vent hole 0.6 Labelled faceplate 8 6 5 4 4.7 3.4 (7.6) Recommended footprint for PCB 6- 1(Diameter of through holes) 6- 1.8(Diameter of lands) 8 1 2 3 10 3 2.54 2.54 1 2.54 2.54 unit(mm) unit(mm) Sensing element/Gauge Connection diagram FPM,FHM Data sheet unit(mm) FPM, FHM i 1.5mA 2 Output voltage R2 Constant current source 3 6 R3 R4 1 6 Zero balancing trimmer (VR0) is available. VR0 :200 R1 1 5 VR0 Note ; Please read instruction "Notes" before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538 4 E-mail : sensor@fujikura.co.jp |
Price & Availability of FPMC-07PGR
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |