![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
POLYFUSE(R) RESETTABLE FUSES LTD Strap Type, 15 V / 24 V Standard UL 1434 1st Edition CSA C22.2 No. 0 CSA TIL No. CA-3A cULus Recognition TUV Specifications Packaging A small pack D standard Materials Insulating material: Terminals: 120 C Operating / Storage Temperature -40 C to +85 C (consider derating) Humidity Ageing +85 C, 85 % R.H., 7 days, 5 % typical resistance change Vibration MIL-LTD-883C, Condition A, no change Marking "P", Part Code, identification, lot number Polyester Tape Nickel Approvals Features Dimensions (mm) Max. Device Surface Temperature in Tripped State This product line similar to the STD family is designed to provide overcurrent protection for rechargable batteries at elevated temperatures. These devices offer hold currents from 0.7 A to 4.3 A and voltages from 15 V to 24 V. S: one slot SS: two slots Dimensions (mm) Model Fig LTD070 LTD070S LTD100 LTD100S LTD100SS LTD180 LTD180S LTD180SS LTD190 LTD260 LTD300 LTD310 LTD340 1 2 1 2 3 1 2 3 1 1 1 1 1 A Min Max 19.9 19.9 20.9 20.9 20.9 24.0 24.0 24.0 21.3 24.0 28.4 24.0 24.0 22.1 22.1 23.1 23.1 23.1 26.0 26.0 26.0 23.4 26.0 31.8 26.0 26.0 B Min Max 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 10.2 10.8 13.0 14.8 14.8 5.2 5.2 5.2 5.2 5.2 5.2 5.2 5.2 11.0 11.9 13.5 15.9 15.9 C Min Max 0.7 0.7 0.6 0.6 0.6 0.6 0.6 0.6 0.5 0.6 0.5 0.6 0.6 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.1 1.0 1.0 D Min 5.5 5.5 4.1 4.1 4.1 4.1 4.1 4.1 5.0 5.0 6.3 5.0 5.0 E Min Max 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 4.8 5.9 6.0 5.9 5.9 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 5.4 6.1 6.6 6.1 6.1 packaging quantity small pack standard 500 500 500 500 500 500 500 500 500 500 500 500 500 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 cURus * * * * * * * * * * * * * LTD070 LTD070S LTD100 LTD100S LTD100SS LTD180 LTD180S LTD180SS LTD190 LTD260 LTD300 LTD310 LTD340 NOTE: I hold = I trip = Vmax = I max = 700 700 1.00 1.00 1.00 1.80 1.80 1.80 1.90 2.60 3.00 3.10 3.40 1.50 1.50 2.50 2.50 2.50 3.80 3.80 3.80 4.20 5.20 6.30 6.00 6.80 15 15 24 24 24 24 24 24 24 24 24 24 24 100 100 100 100 100 100 100 100 100 100 100 100 100 5.0 @ 3.5 5.0 @ 3.5 7.0 @ 5.0 7.0 @ 5.0 7.0 @ 5.0 2.9 @ 9.0 2.9 @ 9.0 2.9 @ 9.0 3.0 @ 10.0 5.0 @ 13.0 4.0 @ 15.0 5.0 @ 16.0 5.0 @ 17.0 1.00 1.00 1.50 1.50 1.50 2.00 2.00 2.00 1.90 2.30 2.00 2.50 2.70 0.100 0.100 0.070 0.070 0.070 0.040 0.040 0.040 0.030 0.025 0.015 0.018 0.016 0.200 0.200 0.130 0.130 0.130 0.068 0.068 0.068 0.057 0.042 0.031 0.030 0.027 0.340 0.340 0.260 0.260 0.260 0.120 0.120 0.120 0.100 0.076 0.055 0.055 0.050 Hold current: maximum current device will pass without tripping in 20 C still air. Trip current: minimum current at which the device will trip in 20 C still air. Maximum voltage device can withstand without damage at rated current (I max) Maximum fault current device can withstand without damage at rated voltage (Vmax) Pd = Power dissipated from device when in the tripped state at 20 C still air. Minimum resistance of device in initial (un-soldered) state. R min= Maximum resistance of device at 20 C measured one hour after tripping for 20 s. R 1max= Caution: Operation beyond the specified rating may result in damage and possible arcing and flame. Specifications are subject to change without notice Order Information 040706 Qty. OrderNumber Model Packaging In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com TUV * * * * * * * * * * * * * Permissible continuous operating current is 100 % at ambient temperature of 20 C (68 F). Model Ihold ITrip Vmax. dc Imax. max. time to trip (mA/A) (A) (V) (A) (s @ A) Pd max. (W) R min.( ) Resistance Approvals R max.( ) RI max.( ) POLYFUSE(R) RESETTABLE FUSES LTD 100.00 A BC A: LTD190 B: LTD180 C: LTD100S 10.00 Time to Trip (s) 1.00 0.10 0.01 1.00 10.00 100.00 Fault Current (A) Thermal Derating Chart Model Ambient Operation Temperature - Ihold (A) -40 C LTD070 LTD070S LTD100 LTD100S LTD100SS LTD180 LTD180S LTD180SS LTD190 LTD260 LTD300 LTD310 LTD340 1.20 1.20 1.86 1.86 1.86 3.13 3.13 3.13 3.32 4.30 5.10 5.36 5.52 -20 C 1.09 1.09 1.60 1.60 1.60 2.68 2.68 2.68 2.86 3.72 4.40 4.58 4.79 0 C 0.85 0.85 1.40 1.40 1.40 2.20 2.20 2.20 2.40 3.10 3.70 3.70 4.00 23 C 0.70 0.70 1.00 1.00 1.00 1.80 1.80 1.80 1.90 2.60 3.00 3.10 3.40 40 C 0.50 0.50 0.83 0.83 0.83 1.33 1.33 1.33 1.48 1.98 2.30 2.36 2.60 50 C 0.45 0.45 0.70 0.70 0.70 1.10 1.10 1.10 1.25 1.69 1.95 2.01 2.24 60 C 0.35 0.35 0.60 0.60 0.60 0.90 0.90 0.90 1.10 1.40 1.60 1.70 1.90 70 C 0.28 0.28 0.44 0.44 0.44 0.65 0.65 0.65 0.79 1.11 1.25 1.30 1.51 85 C 0.16 0.16 0.23 0.23 0.23 0.36 0.36 0.36 0.43 0.60 0.69 0.71 0.78 040706 In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com |
Price & Availability of LTD100
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |