If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Issue: 04 Specification AXE1200 Oscillator type : Crystal Oscillator (PXO) 1200 MHz Date: 2008-01-25 Parameter Nominal frequency Frequency stability Initial tolerance vs. temperature in operating temperature range operating temperature range vs. supply voltage variation vs. load change long term (aging) 1st year long term (aging) following years Frequency adjustment range Mechanical (internal trimmer) RF output Signal waveform Load Amplitude Phase noise min. typ. max. Unit 1 200 1 50 MHz ppm ppm ppm C ppm ppm ppm ppm/y ppm Condition @25C Steady state -30 +85 0.2 0.1 2 1 N.A. Sine wave 50 VS 5% Load 5% @ +25C per year @ +25C N.A. Start-up time Supply voltage VS Current consumption (steady state @ +25C) @25C Operable temperature range Storage temperature range Enclosure (see drawing) (LxWxH) Weight Packing HBM as in IEC 61000-4-2 ESD Sensitivity Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated +7 dBm -140 -135 dBc/Hz -142 -140 dBc/Hz -145 dBc/Hz 10 ms 14.25 15 15.75 V 50 mA -40 +90 C -55 +105 C 54 x 40 x 20 mm 60 gram bulk 1500 V 10 % @ 10 kHz @ 100 kHz @ 1 MHz Ordering Code: Model (Specification) AXE1200 Frequency [MHz] 1200 GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXE1200 page 1(2) .axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com Enclosure drawing Pin# 1 2 3 SMA Symbol N.C. GND VS RF OUT Function No Connection Ground Supply Voltage RF Output Environmental conditions Test Visual inspection, dimensions Solderability Resistance to soldering heat Shock* Bump* IEC 60068 Part ... IEC 60679-1 clause ... 4.3 4.6.3 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Test Ta (235 5)C Method 1 Test Tb Method 1A, 5s Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days 2-20 2-58 2-27 2-29 4.6.8 4.6.6 4.6.7 Vibration, sinusoidal* 2-6 Rapid change of temperature Dry heat Damp heat, cyclic* Cold Climatic sequence* Damp heat, steady state* Endurance tests - ageing - extended aging 2-14 2-2 2-30 2-1 1-7 2-3 4.6.5 4.6.14 4.6.15 4.6.16 4.6.17 4.6.18 4.7.1 4.7.2 30 days @ 85C, OCXO @25C 1000h, 2000h, 8000h @85C AXE1200 page 2(2) .axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany |
Price & Availability of AXE1200
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |