Part Number Hot Search : 
A225M 403IXXKM 2SD1450 S6B0741A 2SC1783 GBPC1510 24C02B 403IXXKM
Product Description
Full Text Search
 

To Download LPS60-M Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Embedded Power for Business-Critical Continuity
LPS60-M Series
60 Watts Medical
Total Power: Input Voltage: # of Outputs: 60 - 80 Watts 85 - 264 VAC 120 - 300VDC Single
Rev. 07.23.07 LPS60-M Series 1 of 3
RoHS
Electrical Specifications
Special Features
* * * * * * * * * * Medical safety approvals Universal input 3" x 5" footprint Remote sense Built in EMI filter Low output ripple Adjustable output voltage Overload protection 110 KHz switching frequency LPX60 enclosure kit available
Input
Input range Frequency Inrush current Input current Efficiency EMI filter Safety ground leakage current 85 - 264 VAC (wide range) 120 - 300VDC 47-440 Hz <18A peak @ 115VAC, <36A peak @230 VAC, cold start @ 25C 1.5A max. (RMS) @ 115 VAC 70% typical at full load FCC Class A conducted; CISPR22 Class A conducted; EN55022 Class A conducted; VDE0878 PT3 Class A conducted <75A @ 50/60Hz; 264VAC input
Output
Maximum power Adjustment range Hold-up time Overload protection 60W for convection; 80W with 30CFM forced air -5, +10% minimum 20ms @ 60W load, 115VAC nominal line
Safety
VDE UL CSA CE 0750/EN60950 (IEC601) 21310-3336-0015 UL2601 E182560 CSA 22.2 No.601.1 LR109492 Mark (LVD)
Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating Overvoltage protection 5V output; 5.7 - 6.7VDC. Other outputs 10% to 25% above nominal output Remote sense Compensates for 0.5V lead drop min. Will operate without remote sense connected. Reverse connection protected.
Environmental Specifications
Operating temperature: 0 to 50C ambient derate each output as 2.5% per degree from 50 to 70C, -20C startup Storage temperature: -40C to +85C Electromagnetic susceptibility: Humidity: Vibration: designed to meet IEC801, -2, -3, -4, -5, -6, Level 3 Operating; non-condensing 5% to 95% RH
Output Power (Watts)
Rev. 07.23.07 LPS60-M Series 2 of 3
Power Derating Curve
80W 30 CFM Forced Air Cooling 60W 40W 30W
Three orthogonal axes, sweep at 1cot/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500Hz, operational Temperature coefficient 0.04% per C MTBF demonstrated >550,000 hours at full load and 25C ambient conditions
40W
20W 0W
Natural Convection Cooling
0C 10C 20C 30C 40C 50C 60C 70C TA - Ambient Temperature - C
Mechanical Drawing
0.22" (5.6) M1 GND
SK201
M2
+ _
Remote Sense Connector Voltage Adj. Pot
3.00" (76.2) 2.55" (64.8)
SK 1
1 3
N L
1 2 3 4 5 6
SK 2
0.22" (5.6)
4.56" (115.8)
0.15" (4) DIA (4 places) 5.00" (127)
1.69" (42.9)
0.12" (3)
Embedded Power for Business-Critical Continuity
Ordering Information
Model Number LPS63-M LPS64-M LPS65-M Output Voltage 12V 15V 24V Maximum Load Minimum with Convection Load Cooling 0A 0A 0A 5A 4A 2.5A Maximum Load with 30CFM forced Air 6.7A 5.3A 3.3A Peak Regulation2 Load1 7.5A 6A 3.8A 2% 2% 2% Ripple P/P (PARD)3 120mV 150mV 240mV
Americas
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698
Rev. 07.23.07 LPS60-M Series 3 of 3
Europe (UK)
Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355
1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10F (tantalum capacitor) in parallel with a 0. F capacitor at rated line voltage and load ranges.
Asia (HK) Pin Assignments
Connector LPS62-M SK1-1 SK1-3 SK2-1 SK2- 2 SK2- 3 SK2-4 SK2-5 SK2-6 SK201-1 SK201-2 Neutral Line +12V +12V +12V Common Common Common +Sense -Sense LPS63-M Neutral Line +15V +15V +15V Common Common Common +Sense -Sense LPS65-M Neutral Line +24 +24 +24 Common Common Common +Sense -Sense
16th - 17th Floors, Lu Plaza 2 Wing Yip Street, Kwun Tong Kowloon, Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888
For global contact, visit:
www.astecpower.com www.artesyn.com technicalsupport@astec.com technicalsupport@artesyn.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
Mating Connectors
AC Input: DC Outputs: Molex 09-50-8031 (USA) Not required for (-T) option 09-91-0300 (UK) PINS: 08-58-0111 Molex 09-50-8061 (USA) Not required for (-T) option 09-91-0600 (UK) PINS: 08-52-0113
Remote Sense: Molex 22-01-2025 PINS: 08-52-0113 Astec Connector Kit #70-841-006, includes all of the above 1. 2. 3. 4. 5. 6. 7. Specifications subject to change without notice. All dimensions in inches (mm), tolerance is 0.02" (0.5mm) Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is safety ground connection. Specifications are for convection rating at factory settings at 115 VAC input, 25C unless otherwise stated. Warranty: 2 year Weight: 0.75lbs/0.34kg
Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring and Services EmersonNetworkPower. com
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. (c)2007 Emerson Electric Co.


▲Up To Search▲   

 
Price & Availability of LPS60-M

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X