Part Number Hot Search : 
CIRCC CTCDR B78148T 68027 P12N8 BCR129 SAA73 TC401
Product Description
Full Text Search
 

To Download S-210-75 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 210W Single Output Switching Power Supply
Features :
AC input range selectable by switch
S-210
series
Protections: Short circuit / Overload / Over voltage / Over temperature 100% full load burn-in test Fixed switching frequency at 90KHz Low cost High reliability 2 years warranty
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE S-210-5 5V 40A 0 ~ 40A 200W S-210-7.5 7.5V 27A 0 ~ 27A 202.5W 100mVp-p 6 ~ 9V 2.0% 0.5% 1.0% S-210-12 12V 17A 0 ~ 17A 204W 120mVp-p 10 ~ 13.2V 1.0% 0.5% 0.5% S-210-13.5 13.5V 15A 0 ~ 15A 202.5W 120mVp-p 12 ~ 15V 1.0% 0.5% 0.5% S-210-15 15V 14A 0 ~ 14A 210W 120mVp-p 13.5 ~ 18V 1.0% 0.5% 0.5% S-210-24 24V 8.8A 0 ~ 8.8A 211.2W 200mVp-p 20 ~ 26.4V 1.0% 0.5% 0.5% S-210-27 27V 7.8A 0 ~ 7.8A 210.6W 200mVp-p 26 ~ 29V 1.0% 0.5% 0.5% S-210-48 48V 4.4A 0 ~ 4.4A 211.2W 200mVp-p 45.6 ~ 52.8V 1.0% 0.5% 0.5%
RIPPLE & NOISE (max.) Note.2 80mVp-p 4.5 ~ 5.7V VOLTAGE TOLERANCE Note.3 2.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE MTBF OTHERS DIMENSION PACKING
NOTE
0.5% 1.0% 20ms/230VAC 47 ~ 63Hz 79% 4.2A/115VAC 35A/115VAC
1000ms, 20ms/230VAC
1000ms, 20ms/115VAC at full load 248 ~ 370VDC 84% 85% 87% 87% 87%
20ms/115VAC at full load
88 ~ 132VAC / 176~264VAC by switch 82% 2.5A/230VAC 50A/230VAC 83%
<3.5mA / 240VAC 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.75 ~ 6.75V 9.4 ~ 10.9V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V 27.6 ~ 32.4V Protection type : Hiccup mode, recovers automatically after fault condition is removed RTH1 85 Protection type : Hiccup mode, recovers automatically after fault condition is removed -20 ~ +50 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ) I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC 244.7K hrs min. MIL-HDBK-217F (25 215*115*50mm (L*W*H) 0.95Kg; 12pcs/12.4Kg/0.92CUFT 31.05 ~ 36.45V 55.2 ~ 64.8V
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
File Name:S-210-SPEC 2007-10-25
210W Single Output Switching Power Supply
Mechanical Specification
Air flow 18CFM (5~12V) direction
27.5 32.5 117.5 177.5 150
S-210
Case No. 912E
series
Unit:mm
LED +V ADJ. 9 8 7 6 5 4 3 2 1
135
9.5
4-M4 L=5mm
50.5
32.5
8
5-M3 L=3mm
15 215 32.5 150
16
10
115
50
95
13 max.
25 50
C L
Terminal Pin No. Assignment :
Pin No. 1 2 3 Assignment AC/L AC/N FG Pin No. Assignment 4~6 DC OUTPUT -V 7~9 DC OUTPUT +V
6-M4 L=6mm
Block Diagram
230 115 EMI FILTER ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. O.T.P.
fosc : 90KHz
I/P
+V -V
FG O.L.P.
PWM CONTROL
Derating Curve
Static Characteristics
15 ~ 48V Ta=25
18CFM forced air cooling (L=10cm) 5~12V
100
100 90 80
80 75 60
Natural convection cooling(13.5~48V) Natural convection cooling(5~12V)
70
5 ~ 13.5V
LOAD (%)
LOAD (%)
0 10 20 30 40 50 60 (HORIZONTAL)
50 40
60 50 40
20
-20
88 176
100 190
132 264
AMBIENT TEMPERATURE ( )
File Name:S-210-SPEC 2007-10-25


▲Up To Search▲   

 
Price & Availability of S-210-75

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X