S/MON/SC867910/B/27/02/2002 page 1 /2 F/GB Relais statique monophase de puissance Power Solid State Relay * Sortie AC synchrone : 24-520VAC-75A * Possibilite de protection IP20 en option : Capot 1K460000 * Adapte a tout type de charges * 24-520VAC -75A Zero-Cross AC Output. * IP20 Protection optional (1K460000). * Designed for all types of loads 10102 Dimensions/Size SC867910 90-240VAC control 75A/400VAC output Application typique/Typical application 27 22,8 0,5 24-520VAC 28 O4,7 M4 protection reseau line protection 1 19,6 1 58,2 43,2 2 47,6 Entree control 90-240VAC = 4 7,5 3 2 25,8 TOLERANCES: 25,4 44,5 0,3 M3 * 1-2 peuvent etre inversees/ 1 -2 can be changed * le relais doit etre monte sur dissipateur thermique / SSR must be mounted on a heatsink * option : couvercle de protection des bornes : 1K460 000 / cover : 1K460 000 5,1 CHARGE/ LOAD Caracteristiques de commande (a 20C) / Control characteristics (at 20C) Parametre / Parameter Tension de commande / Control voltage Courant de commande / Control current (@ Uc ) Tension de relachement/Release voltage Resistance interne / Input internal resistor fig.1 Symbol Uc Ic Uc off Rc Min 90 3 1 AC Nom Max 240 8 Unit V mA V K 8 fig. 1 :Caracteristique d'entree / Control characteristic fig1 : Caracteristique d'entree / Control characteristic 6 Ic (mA) 30 4 2 Caracteristiques d'entree-sortie (a 20C) / Input-output characteristics (at 20C) Isolement entree-sortie/Input-output isolation @500m Ui 4000 Isolement sortie-semelle/Output-case isolation @500m Ui 3300 Tension assignee isolement/Rated impulse voltage Uimp 4000 Caracteristiques generales / General characteristics Parametre / Parameter Poids/Weight Plage de temperature de stockage / Storage temperature range Plage de temperature de fonctionnement/Operating temperature range VRMS VRMS V 0 0 0 20 40 60 8 0 100 120 140 160 180 200 220 240 Uc (V) Conditions Symbol Typ. 90 -40 / +100 Unit g C C Proud to serve you All technical caracteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis. celduc r e l a i s S/MON/SC867910/B/27/02/2002 Caracteristiques de sortie(a 20C) / Output characteristics (at 20C) Parametre / Parameter Tension de charge / Load voltage Plage tension de fonctionnement / Operating range Tension crete / Peak voltage Niveau de synchonisation / Synchronizing level Tension d'amorcage / Latching voltage Courant nominal AC-51/ AC-51 nominal current Courant nominal AC-53/ AC-53 nominal current Courant de surcharge non repetitif /Non repetitive overload current Chute tension directe crete/ On state voltage drop Courant de fuite etat bloque/ Off state leakage current Courant de charge minimum / Minimum load current Temps de fermeture/ Turn on time Temps d'ouverture/ Turn off time Plage de frequence / Operating frequency range dv/dt etat bloque / Off state dv/dt dI/dt maximum non repetitif/ Maximum di/dt non repetitive I2t (<10ms) EMC Test d'immunite conduite / Conducted immunity level EMC Test d'immunite conduite / Conducted immunity level Conformite / Conformity 110 page 2 / 2 F/GB Symbol Typ. Unit Ue 400 V rms Ue min-max 24-520 V rms Up 1200 V Usync 12 V Ie nom Ua 10 V ( see Fig. 2 ) Ie AC-51 75 A rms ( see Fig. 2 ) Ie AC-53 16 A rms tp=10ms (Fig. 3) Itsm 1000 A @ Ie nom Vd 1,35 V @Ue, 50Hz Ilk <3 mA Ie min 5 mA Uc nom DC ,f=50Hz ton max 30 ms Uc nom DC ,f=50Hz toff max 30 ms f 0,1-440 Hz dv/dt 500 V/s di/dt 50 A/s I2t 5000 A2s IEC 1000-4-4 (burst) 2kV criterion A IEC 1000-4-5(schocks) 2kV crit.A with external VDR EN60947-4-x 0,55K/W 110 100 Conditions Total wasted power (W) Fig. 2 Courbes thermiques / Thermal characteristics Full on-state 0,75K/W 100 90 80 70 0,95K/W 70 % duty 1,6K/W 90 80 70 60 50 40 30 20 50 % duty 60 50 40 (*) : minimum value : typically : 6600A2s 2,2K/W 30 % duty 30 20 10 0 0 10 20 30 40 50 60 70 RMS load current (A) 80 90 0 without heatsink 10 0 10 20 30 40 50 60 70 80 90 100 Ambient temperature (C) Fig.3 Surcharge de courant : Itsm (Apeak) = f(t) pour modele 75A(Itsm=1000A) Surge current : Itsm (Apeak) = f(t) for 75A models with Itsm =1000A 1500 Itsm (Apeak) 1 -Itsm non repetitif sans tension reappliquee est donne pour la determination des protections. No repetitive Itsm is given without voltage reapplied for the determination of the protection. 2 -Itsm repetitif est donne pour des surcharges de courant (Tj initiale=70C). La repetition de ces surcharges de courant diminue la duree de vie du Relais. Repetitive Itsm is given for inrush current with initial Tj = 70C. The repetition of the surge current decrease the lifetime SSR's . 1000 Surcharge de courant non repetitive sans tension reappliquee / No repetive surge current without voltage reapplied. Surcharge de courant repetitive avec tension reappliquee Repetive surge current with voltage reapplied. 500 0 0,01 0,1 t (s) 1 10 Precautions : * Les relais a semiconducteurs ne procurent pas d'isolation galvanique entre le reseau et la charge. Cautions : * Semiconductor relays don't provide any galvanic insulation between the load and the mains. celduc r e l a i s www.celduc.com Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19 |
Price & Availability of SC867910
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |