 100W Single Output Switching Power Supply
Features :
CLG-100
series
Universal AC input / Full range Protections:Short circuit/Over load/Over voltage/Over temperature Built-in active PFC function IP67 design for indoor or outdoor installations UL1310 Class 2 power unit Cooling by free air convection 100% full load burn-in test High realibility Suitable for LED lighting and moving sign applications 3 years warranty (Note.7)
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER VOLTAGE ADJ. RANGE CURRENT ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR INPUT EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT(max.) LEAKAGE CURRENT OVER CURRENT PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE
Note.4
( for 48V only)
( except for 48V )
IP67
CLG-100-36 36V 2.65A 0 ~ 2.65A 95.4W 150mVp-p CLG-100-48 48V 2A 0 ~ 2A 96W 200mVp-p
CLG-100-12 12V
Note.6 5A Note.6 0 ~ 5A Note.6 60W
CLG-100-15 15V 5A 0 ~ 5A 75W 150mVp-p
CLG-100-20 20V 4.8A 0 ~ 4.8A 96W 150mVp-p
CLG-100-24 24V 4A 0 ~ 4A 96W 150mVp-p
CLG-100-27 27V 3.55A 0 ~ 3.55A 95.85W 150mVp-p
RIPPLE & NOISE (max.) Note.2 150mVp-p OUTPUT
Fixed. Can be modified between 0% ~ -15% rated output voltage Fixed. Can be modified between 3% ~ -25% rated output current 3.0% 1.0% 2.0% 1200ms, 80ms / 230VAC 60ms / 230VAC
Note.5 90 ~ 264VAC
3.0%
3.0%
3.0%
3.0%
2.0%
2.0%
1200ms, 80ms / 115VAC at full load
30ms / 115VAC at full load
47 ~ 63Hz PF>0.95/230VAC 83% PF>0.98/115VAC at full load 85% 87% 87% 87% 0.45A/230VAC 87% 20V ~ 48V:1.1A/115VAC 87% 0.55A/230VAC 15V:0.9A/115VAC
12V:0.8A/115VAC 0.4A/230VAC COLD START 40A/230VAC 0.5mA / 240VAC 95 ~ 100%
Protection type : Constant current limiting, recovers automatically after fault condition is removed 13 ~ 16V 16.5 ~ 20V 22 ~ 27V 27 ~ 34V 29 ~ 36V 39 ~ 48V Protection type : Shut down and latch off o/p voltage, re-power on to recover 90 10 (RTH2) (Refer to output load derating curve), -40 , 10 ~ 95% RH (0 ~ 50 ) possible Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 -40 ~ +80 0.03%/ 20 ~ 90% RH non-condensing
52 ~ 64V
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1310 Class 2, TUV EN60950-1, CAN/CSA C22.2 No. 223-M91(except for 48V),IP67 Approved
I/P-O/P:4.25KVDC SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms/500VDC EMC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING
NOTE
Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A 301Khrs min. MIL-HDBK-217F (25 ) 222*68*39mm (L*W*H) 1.0Kg; 12pcs/13Kg/0.49CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Please refer to OLP characteristics. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2. 7. 3 years warranty is guaranteed for operating ambient temperature no higher than 68 .
File Name:CLG-100-SPEC 2006-08-30
100W Single Output Switching Power Supply
Mechanical Specification
222.2 12 9.6 300 20 198.2
CLG-100
Case No. 954A
series
Unit:mm
9.4
L(Brown) N(Blue) FG(Greed/Yellow)
300 20
34.2
18AWG 3C
18AWG 2C
+V(Red) -V(Black)
9.4
68
4.2 4PL
Block Diagram
POWER SWITCHING RECTIFIERS & FILTER O.L.P. FG PFC CONTROL DETECTION CIRCUIT O.V.P.
Fosc : 100KHz
I/P
EMI FILTER & RECTIFIERS
PFC CIRCUIT
38.75
+V -V
O.L.P.
PWM & PFC CONTROL
OLP Characteristics
100
VO (%)
50 (max.)
0
50
95
(Vo Io<100VA)
IO(%)
Derating Curve
100
Static Characteristics
fosc : 100KHz
100 90
80
80 70
60
LOAD (%)
40
LOAD (%)
-25 -5 0 15 30 50 60 70 (HORIZONTAL)
60 50 40
20
-30
90
100
125
135
145
155 165
175
180
200
230
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (V) 60Hz
File Name:CLG-100-SPEC 2006-08-30


▲Up To Search▲   

 
Price & Availability of CLG-100-12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X