![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
H HiTRON 2008/02/18 UNIVERSAL INPUT HARMONIC CORRECTION AC-DC MEDICAL AND IEC APPLICATION OPEN FRAME SINGLE & MULTI-OUTPUT 150 WATTS INTERNAL SWITCHING POWER SUPPLIES HIMP151 SERIES FEATURES: 5" X 3"* X 1.38" COMPACT SIZE ACCOMMODATE UNIVERSAL AC SOURCES MEET IEC 61000-3-2 HARMONIC CORRECTION MEET UNIVERSAL SAFETY STANDARDS EMI MEET CISPR EN 55022/EN 55011 & FCC CLASS B CONDUCTED CE MARKING COMPLIANCE SPECIFICATION INPUT SPECIFICATION Input Voltage: Typ. 90-264Vac with PFC. Input Connector: V-M connector. Input Frequency: 47-63Hz. Inrush Current: 9.3-11.3Arms @230Vac. Input Current: Typ. 2.2A @115Vac, 0.9A @230Vac. Dielectric Withstand: Meet IEC 60950-1. EMI: Meet CISPR EN 55022 & FCC Class B conducted. Meet CISPR EN 55011 & FCC Class B conducted. Hold-up Time: Typ. 90mS @115Vac & 230Vac. Power Factor & Harmonic Correction: Meet IEC 61000-3-2, PF typ. 0.99 @ full load. Over Temperature Protection: Installed. Leakage Current: 0.40-0.50mA @230Vac touch current. OUTPUT SPECIFICATION Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Connector: V-M connector. Output Wattage: Max. 150 watts. Line Regulation: Typ. 1.0%. Load Regulation: Single O/P VO1 3.0%. Dual O/P VO1 3.0% VO2 1.0% Triple O/P VO1 3.0% ( 8% for 3.3V), VO2/VO3 3.0%. Quad O/P VO1/VO2/VO3/VO4 3.0% Noise & Ripple: Typ. 1.0-2.0% peak to peak. OVP: Built-in at VO1 and VO2. Adjustability: Available at VO1 and VO2. Overload Protection (OLP): Fully protected against output overload and short circuit. OLP set at about 125-150% rating output wattage. Consult the factory for OLP setting. Operating Temperature: 0 to +50C under 30 CFM forced air cooling for full load. Storage Temperature: -20 to +85C. Temperature Coefficient: Typ. 0.04% /C. Cooling: Requested 30 CFM forced air flow for full load. Construction: U-bracket format. Power Density: 6.52-7.24 Watts / Cubic Inch . GENERAL SPECIFICATION Efficiency: Typ. 76-80% various with output. Switching Frequency: 68K Hz. Circuit Topology: Single Fixed frequency forward circuit. Dual/Triple/Quad: Fixed freq. flyback circuit. Transient Response: Output voltage returns in less than 14.8-25.2mS following a 25% load change. Safety Standard: IEC 60950-1 Class I for IEC use. IEC 60601-1 Class I for Medical use. Note: Due to requests in market and advances in technology, specifications subject to change without notification. For the details of safety approval, please consult the factory. OUTPUT VOLTAGE / CURRENT RATINGS CHART SINGLE OUTPUT (Under air cooling) MODEL NO. MAIN VO1 @ Typ. Volt. Max. 5V 12V 15V 24V 30A 12.5A 10.0A 6.3A HIMP151-S050270 27A HIMP151-S120125 12.5A HIMP151-S150100 10.0A HIMP151-S240063 6.3A 2008/02/18 DUAL OUTPUT (Under forced air cooling) MODEL NO. HIMP151-D050I HIMP151-D050M HIMP151-D120I HIMP151-D150K MAIN VO1 @ Typ. Volt. Max. 15.00A 15.0A 6.25A 5.0A +5V +5V +12V +15V 15.00A 15.0A 6.25A 5.00A AUX. VO2 @ Typ. Max. Volt. 6.00A 3.00A 6.25A 5.00A +12V +24V +12V +15V 6.00A 3.00A 6.25A 5.00A TRIPLE OUTPUT (Under forced air cooling) MODEL NO. HIMP151-T033EI HIMP151-T050II HIMP151-T050KK MAIN VO1 @ Typ. Volt. Max. 18A 15A 15A +3.3V +5.0V +5.0V 20A 15A 15A AUX. VO2 @ Typ. Max. Volt. 13.5A 5.5A 4.5A +5V +12V +15V 15A 5.5A 4.5A AUX. VO3 Typ. Volt. Max. 0.8A 0.8A 0.5A +12V +12V +15V 0.8A 0.8A 0.5A QUAD OUTPUT (Under forced air cooling) MODEL NO. MAIN VO1 @ Typ. Volt. Max. AUX. VO2 @ Typ. Max. Volt. AUX. VO3 Typ. Volt. Max. -15V 0.8A AUX. VO4 Typ. Max. Volt. 0.5A -5V 0.5A 15A 15A 4A 4A 0.8A HIMP151-Q050KKE +5V +15V Symbol: "" OVP built-in. "@" Adjustable. "" Post -Regulated Remark: Please refer to the derating chart depending on ambient temperature and fan cooling. MECHANICAL DIMENSIONS: MM [INCHES] WEIGHT: 385.0g (13.4 Oz.) SINGLE DUAL/TRIPLE/QUAD INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT AC INPUT ASSIGNMENT AC AC- AC-L N G SINGLE O/P VO1 DCCOM VO1 DUAL O/P VO2 DCCOM VO1 TRIPLE O/P VO2 VO3 DCCOM VO1 VO2 QUAD O/P VO3 +VO4 DC COM P1- P1- P1CNTR & PIN # L N G P2-1,2, 3,4,5,6 P2-7,8,9 P2-1,2,3, P2-9,10 10,11,12 4 P2-5, 6,7,8 P2-1,2, 3,4 P2-9,10 P2-11 P2-5, 6,7,8 P2-1, 2,3,4 P2-9,10 P2-11 P2-12 P2-5,6, 7,8 Mating connector: Moles 5195 or 5239 series. DERATING CHART HIMP151-S050270 Forced air cooling- 5CFM Power derating 2008/2/18 Forced air cooling- 20CFM Power derating Forced air cooling- 30CFM Power derating 100 90 80 70 60 % 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 deg C 100 90 80 70 60 % 50 40 30 20 10 0 0 10 20 30 40 50 deg C 60 70 80 90 100 100 90 80 70 60 % 50 40 30 20 10 0 0 10 20 30 40 50 deg C 60 70 80 90 100 HIMP151-D050I Forced air cooling- 5CFM Power derating Forced air cooling- 20CFM Power derating Forced air cooling- 23CFM Power derating 100 90 80 70 60 % 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 deg C 100 90 80 70 60 % 50 40 30 20 10 0 0 10 20 30 40 50 deg C 60 70 80 90 100 100 90 80 70 60 % 50 40 30 20 10 0 0 10 20 30 40 50 deg C 60 70 80 90 100 HIMP151-T033EI Forced air cooling- 5CFM Power derating Forced air cooling- 20CFM Power derating Forced air cooling- 30CFM Power derating 100 90 80 70 60 % 50 40 30 20 10 0 0 10 20 30 40 50 deg C 60 70 80 90 100 100 90 80 70 60 % 50 40 30 20 10 0 0 10 20 30 40 50 deg C 60 70 80 90 100 100 90 80 70 60 % 50 40 30 20 10 0 0 10 20 30 40 50 deg C 60 70 80 90 100 HIMP151-Q050KKE Forced air cooling- 5CFM Power derating Forced air cooling- 20CFM Power derating Forced air cooling- 26CFM Power derating 100 90 80 70 60 % 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 deg C 100 90 80 70 60 % 50 40 30 20 10 0 0 10 20 30 40 50 deg C 60 70 80 90 100 100 90 80 70 60 % 50 40 30 20 10 0 0 10 20 30 40 50 deg C 60 70 80 90 100 |
Price & Availability of HIMP151
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |