![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
65 WATT MEDICAL POWER SUPPLIES DESCRIPTION The PM65 series of compact, open PCB constructed, AC-DC switching power supplies are capable of delivering 50 to 65 watts of continuous power. They are ideally suited for use in medical equipment not for patient contact, and operate at 85 to 264 VAC input voltage without the need of voltage selection. All models meet the safety requirements of UL, CSA and IEC. PM65 SERIES (MDD) F E ATU R E S Low safety ground leakage current M e e t E N 5 5 0 11 a n d F C C C l a s s B Small size, light weight 100% burn-in W i d e i n p u t r a n g e 8 5 t o 2 6 4 VA C Input surge current protection Overvoltage protection Overcurrent protection S a f e t y St a n d a r d A p p ro v a ls I N P U T S P E C I F I C ATI O N S Input voltage Input frequency Input current Leakage current 85 to 264 VAC 47 to 63 Hz 1.60Armsfor 115VAC 1.00Armsfor 230VAC 90uA max. @ 115VAC, 60Hz 150uA max. @ 230VAC, 50Hz UL 2601-1 CSA C22.2 No. 601.1 TUV EN60601-1 OUTPUT SPECIFICATIONS Output voltage/current Total output power Ripple and noise Overvoltage protection See rating chart 65 watts maximum 1 peak to peak maximum Provided on output #1 only; set at 112 - 132 of its nominal output voltage All outputs protected to short circuit conditions All outputs 0.04 / maximum Maximum excursion of 4or better on all models, recovering to 1of final value within 500us after a 25 step load change GENERAL SPECIFICATIONS Switching frequency 32KHz 5KHz 70minimum on single output models with Vo Efficiency 12V, 65% minimum on the others. 10 msec minimum at 110VAC Hold-up time Line regulation 0.5maximum at full load 15 amps @ 115VAC, or 30 amps @ 230VAC, at Inrush current 25 cold start Withstand voltage 4000VAC from input to output 1500VAC from input to ground 500VAC from output to ground 400,000 hours minimum at full load at 25 MTBF ambient , calculated per MIL-HDBK-217F EMC PERFORMANCE (EN60601-1-2: 2001) Class B conducted, Class B radiated E N 5 5 0 11 : Class B conducted, Class B radiated FCC: Class B conducted, Class B radiated VCCI: EN61000-3-2: Harmonic distortion , Class A EN61000-3-3: Line flicker EN61000-4-2: EN61000-4-3: EN61000-4-4: EN61000-4-5: EN61000-4-6: EN61000-4-8: E N 6 1 0 0 0 - 4 - 11 : ESD, 8KV air and 6KV contact Radiated immunity, 3V/m, for 80~2500MHz Fast transient/burst, 2KV Surge, 1KV diff., 2KV com. Conducted immunity, 3Vrms Magnetic field immunity, 3A/m Voltage dips, 30% reduction for 500ms, 60% reduction for 100ms and >95% reduction for 10ms Overcurrent protection Temperature coefficient Transient response E N V I R O N M E N TA L S P E C I F I C ATI O N S Operating temperature Storage temperature Relative humidity Derating 0 to +70 -40 to +85 5to 95non-condensing Derate from 100at +50 linearly to 50% at +70 Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 sales@trumpower.com www.TRUMPower.com MEDICAL GRADE OUTPUT VOLTAGE/CURRENT RATING CHART (1) (2) Model PM65-10A PM65-12A PM65-13A PM65-14A PM65-16A PM65-17A PM65-23A PM65-24A PM65-25A PM65-30A PM65-31A PM65-32A PM65-33A PM65-39A PM65-40A Notes: Output #1 Vnom. Imin. Imax. 5V 0A 10A 12V 0A 5.5A 15V 0A 4.5A 24V 0A 3.0A 30V 0A 2.5A 36V 0A 2.2A +5V 1A 6.0A +5V 1A 6.0A +5V 1A 6.0A +5V 1A 6.0A +5V 1A 6.0A +5V 1A 6.0A +5V 1A 6.0A +5V 1A 6.0A +5V 1A 6.0A Output #2 Vnom. Imin. Imax. (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) +12V 0.5A 3.0A +15V 0.4A 3.0A +24V 0.3A 2.0A +12V 0.5A 3.0A +12V 0.5A 3.0A +15V 0.4A 3.0A +15V 0.4A 3.0A +24V 0.3A 2.0A +12V 0.5A 3.0A Output #3 Vnom. Imin. Imax. (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) -5V 0.1A 0.5A -12V 0.1A 0.5A -15V 0.1A 0.5A -12V 0.1A 0.5A -12V 0.1A 0.5A -12V 0.1A 0.5A Tol. 2% 1% 1% 1% 1% 1% 3% 3% 3% 3% 3% 3% 3% 3% 3% Tol. Tol. PM65 SERIES Output #4 Vnom. Imin. Imax. Tol. (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) -5V 0.1A 0.5A 10% Maximum Output Power 50W 65W 65W 65W 65W 65W 65W 65W 65W 65W 65W 65W 65W 65W 65W 5% 5% 5% 5% 5% 5% 5% 5% 5% 10% 10% 10% 10% 10% 10% (1) All multiple output models may be operated at no-load without damage. At no-load, output voltage tolerance increases to 10% (2) Safety agency approvals are for the above listed models in PCB format. To order a model with a metallic L-bracket or box, change suffix "A" to "B" for L-bracket format or to "C" for enclosed format (mechanical details shown in page 7-2), e.g. PM65-25C. MECHANICAL SPECIFICATIONS NOTES: 1. Dimensions shown in inch [mm] 2. Tolerance 0.02 [0.5] maximum 3. Input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal. 4. Output connector mates with Molex housing 09-50-3081 and Molex 2878 series crimp terminal. 5. Weight: 400 grams (PCB format) 6. The "" marked mounting hole is for system grounding through a metallic stand-off to the system chassis. PIN CHART PIN MODEL PM65-10A PM65-12A PM65-13A PM65-14A PM65-16A PM65-17A PM65-23A PM65-24A PM65-25A PM65-30A PM65-31A PM65-32A PM65-33A PM65-39A PM65-40A 1 OUTPUT #1 2 OUTPUT #1 3 OUTPUT #1 4 OUTPUT #1 5 6 7 8 RETURN RETURN RETURN RETURN OUTPUT #1 OUTPUT #1 COMMON RETURN COMMON RETURN OUTPUT #2 OUTPUT #2 N.C. N.C. OUTPUT #1 OUTPUT #1 OUTPUT #1 OUTPUT #1 COMMON RETURN COMMON RETURN COMMON RETURN COMMON RETURN OUTPUT #2 OUTPUT #2 OUTPUT #2 OUTPUT #2 OUTPUT #3 OUTPUT #3 N.C. OUTPUT #4 Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 sales@trumpower.com www.TRUMPower.com |
Price & Availability of PM65-25A
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |