|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
125W Quad Output Switching Power Supply Features : RQ-125 series Protections: Short circuit / Overload / Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test All using 105 long life electrolytic capacitors Withstand 300VAC surge input for 5 second High operating temperature up to 70 Withstand 5G vibration test High efficiency, long life and high reliability 3 years warranty .. SPECIFICATION MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY MTBF DIMENSION PACKING RQ-125B CH1 5V 11A Note.6 2 ~ 12A Note.6 120W RQ-125C CH2 12V 4.5A CH3 -5V 1A CH4 -12V 0.5A 0 ~ 1A CH1 5V 10A 2 ~ 12A 122.5W CH1: 4.75 ~ 5.5V 2.0% +8,-3% 0.5% 1.0% 1.0% 3.0% CH2 15V 4A 0.5 ~ 4A CH3 -5V 1A 0.1 ~ 1A CH4 -15V 0.5A 0 ~ 1A RQ-125D CH1 5V 8A 2 ~ 12A 124W CH1: 4.75 ~ 5.5V 2.0% +8,-3% 0.5% 1.0% 1.0% 3.0% CH2 12V 2.5A 0.5 ~ 4A CH3 24V 2A CH4 -12V 0.5A 0.5 ~ 4.5A 0.1 ~ 1A 0.1 ~ 2.5A 0 ~ 1A RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 120mVp-p 150mVp-p 80mVp-p CH1: 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% +8,-3% Note.4 Note.5 +6,-10% 1.0% 6.0% 5.0% 1.0% 2.0% +6,-10% 1.0% 6.0% 5.0% 1.0% 2.0% 8.0% 1.0% 5.0% 5.0% 1.0% 2.0% 0.5% 1.0% 1.0% 3.0% 500ms, 20ms/230VAC 25ms/230VAC 47 ~ 63Hz 79% 1200ms, 30ms/115VAC at full load 248 ~ 373VDC(Withstand 300VAC surge for 5sec. Without damage) 30ms/115VAC at full load 88 ~ 132VAC / 176 ~ 264VAC selected by switch 80% 82% 3A/115VAC 2A/230VAC COLD START 40A/230VAC <2mA / 240VAC 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A 203.1Khrs min. MIL-HDBK-217F (25 ) 199*98*38mm (L*W*H) 0.7Kg; 20pcs/14Kg/0.8CUFT SAFETY & EMC (Note 7) OTHERS NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. 6. Each output can work within current range. But total output power can't exceed rated output power. 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. File Name:RQ-125-SPEC 2007-03-22 125W Quad Output Switching Power Supply Mechanical Specification 197 RQ-125 Case No. 902 series Unit:mm 9 1 8.25 2 3 4 80 98 38 3.5 5 6 7 8 7 3.5 4- M 3 4.5 57.5 199 120 6.5 190 18 9.5 9 22 157 Terminal Pin No. Assignment Pin No. 1 2 3 Assignment AC/L AC/N FG Pin No. 4 5 6 Assignment DC OUTPUT -V4 DC OUTPUT V3 DC OUTPUT +V2 Pin No. 7 8 Assignment DC OUTPUT COM DC OUTPUT +V1 Derating Curve Static Characteristics Ta=25 100 80 60 LOAD (%) 40 20 -25 -25 0 0 10 20 30 40 50 60 70 (VERTICAL) (HORIZONTAL) LOAD (%) 88 176 95 190 100 200 115 230 120 240 28.5 3-M 3 18 3.5 85.5 7 132 264 AMBIENT TEMPERATURE ( ) 3.5 INPUT VOLTAGE (VAC) 60Hz File Name:RQ-125-SPEC 2007-03-22 |
Price & Availability of RQ-125 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |