![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
DRA10 SERIES AC - DC DIN RAIL MOUNTABLE 10W CLASS 2 POWER SUPPLY INDUSTRIAL CONTROL EQUIPMENT FEATURES UL / cUL / TUV / CE UNIVERSAL INPUT 90~265VAC HIGH EFFICIENCY UP TO 76% SHORT CIRCUIT PROTECTION INTERNAL INPUT FILTER 2 YEARS WARRANTY MODEL LIST MODEL NO. INPUT VOLTAGE 90~265 VAC 90~265 VAC 90~265 VAC 90~265 VAC OUTPUT OUTPUT WATTAGE VOLTAGE Single Output Models 10 WATTS 10 WATTS 10 WATTS 10 WATTS + 5 VDC + 12 VDC + 15 VDC + 24 VDC OUTPUT CURRENT 2000 mA 840 mA 670 mA 420 mA EFF. (min.) 71% 73% 74% 74% EFF. (typ.) 73% 75% 76% 76% DRA10-05 DRA10-12 DRA10-15 DRA10-24 SPECIFICATION All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed GENERAL Characteristics Switching frequency Isolation voltage Isolation resistance Ambient temperature Derating Storage temperature Relative humidity Dimension Cooling Case material Conditions Vi nom, Io nom Input / Output Input / Output, @ 500VDC Operating at Vi nom Vi nom,from +61 C to +71 C Non operational Vi nom, Io nom L90 x W22.5 x D115 Free air convection Plastic o o min. 100 3,000 100 -20 -25 20 typ. max. unit KHz VAC M + 71 3 + 85 95 o o C C %/ C o % RH mm INPUT SPECIFICATIONS Characteristics Rated input voltage Input voltage range Line frequency Inrush current Io nom Ta min ... Ta max, Io nom Vi nom, Io nom Io nom Vi : 115VAC Vi : 230VAC AC in DC in Conditions min. 100 90 120 47 typ. max. 240 265 370 63 10 18 unit VAC VAC VDC Hz A A www.chinfa.com 2008.08.19 sales@chinfa.com DRA10 SERIES IND. CONT. EQ. SPECIFICATION All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed OUTPUT SPECIFICATIONS Characteristics Output voltage accuracy Minimum load Line regulation Load regulation Transient recovery time Temperature coefficient Ripple & noise Hold up time Voltage trim range DC ON indicator threshold at start up Vi nom Io nom, Vi min ...Vi max Vi nom, Io min ...Io nom 50% load, step changed Vi nom, Io min Vi nom, Io nom,BW = 20MHz Io nom Vi nom, Io nom Vi nom, Io nom Vi = 115VAC Vi = 230VAC 5V ...15V models 24V model 5V model 12V model 15V model 24V model DC LOW indicator threshold after start up Vi nom, Io nom 5V model 12V model 15V model 24V model Efficiency Vi nom, Io nom, Po / Pi 25 100 - 10 - 10 4.5 10.8 13.5 21.6 3.75 9 11.25 18 Up to 76%, See model list 4.5 10.8 13.5 21.6 + 15 + 20 300 0.02 50 o Conditions Vi nom, Io min ...Io nom min. 0 typ. max. 1 1 2 unit % % % % S %/C mV ms ms % % VDC VDC VDC VDC VDC VDC VDC VDC CONTROL AND PROTECTION Characteristics Input fuse Rated over load protection Over voltage protection Output short circuit Vi nom Vi nom, Io nom Vi nom, Io nom 110 125 Hiccup mode Conditions min. typ. max. 145 145 unit % % T2A / 250VAC internal APPROVALS AND STANDARDS UL / cUL TUV CE UL508 Listed UL60950-1, UL1310 Class 2 Power Supply Recognized EN60950-1 EN61000-6-3 / EN55022 Class B, EN61000-3-2 , EN61000-3-3 EN61000-6-2 / EN55024 / EN61204-3 CIRCUIT SCHEMATIC Block diagram for DRA10 series L Fuse Line Filter N Y Inrush Current Switching Limiter and Device Rectifier Vo + Rectifier Current Detection Vo - Control Opto Isolation Opto Isolation Reference & Error Amp. Over Voltage Detection Output Level Detection Vout ADJ. www.chinfa.com 2008.08.19 DC ON (Green LED) DC LOW (Red LED) sales@chinfa.com DRA10 SERIES IND. CONT. EQ. MECHANISM & PIN CONFIGURATION mm [inch] 22.5 [0.89] 115 [4.53] 21 CONSTRUCTION Easy snap-on mounting onto the DIN-Rail (TS35/7.5 or TS35/15), unit sits safely and firmly on the rail; no tools required even to remove V- V+ DC Output LO ON INSTALLATION Ventilation / Cooling Normal convection All sides 25mm free space For cooling recommended Connector size range Solid:0.2-2.0mm2(AWG24-14) (use copper conductors only) 90.0 [3.60] Vout ADJ. NL 345 PHYSICAL CHARACTERISTICS CASE SIZE CASE MATERIAL WEIGHT 90 x 22.5 x 115 mm 3.6 x 0.89 x 4.53 inches Plastic 120 g PIN ASSIGNMENT PIN NO. OUT 1 2 3 4 5 Designation V+ VN L ON LO Vout ADJ. Description Positive output terminal Negative output terminal Ground this terminal to minimize high-frequency emissions Input terminals (neutral conductor, no polarity at DC input) Input terminals (phase conductor, no polarity at DC input) Operation indicator LED DC LOW indicator LED Trimmer- potentiometer for Vout adjustment DERATING 100 Power out [ % ] 70 0 -20 Temperature [ oC ] www.chinfa.com 2008.08.19 OTHER IN 61 71 sales@chinfa.com DRA10 SERIES AC - DC DIN RAIL MOUNTABLE 10W CLASS 2 POWER SUPPLY INDUSTRIAL CONTROL EQUIPMENT FEATURES UL / cUL / TUV / CE UNIVERSAL INPUT 90~265VAC HIGH EFFICIENCY UP TO 76% SHORT CIRCUIT PROTECTION INTERNAL INPUT FILTER 2 YEARS WARRANTY MODEL LIST MODEL NO. INPUT VOLTAGE 90~265 VAC 90~265 VAC 90~265 VAC 90~265 VAC OUTPUT OUTPUT WATTAGE VOLTAGE Single Output Models 10 WATTS 10 WATTS 10 WATTS 10 WATTS + 5 VDC + 12 VDC + 15 VDC + 24 VDC OUTPUT CURRENT 2000 mA 840 mA 670 mA 420 mA EFF. (min.) 71% 73% 74% 74% EFF. (typ.) 73% 75% 76% 76% DRA10-05A DRA10-12A DRA10-15A DRA10-24A SPECIFICATION All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed GENERAL Characteristics Switching frequency Isolation voltage Isolation resistance Ambient temperature Derating Storage temperature Relative humidity Dimension Cooling Case material Conditions Vi nom, Io nom Input / Output Input / Output, @ 500VDC Operating at Vi nom Vi nom,from +61 C to +71 C Non operational Vi nom, Io nom L90 x W22.5 x D115 Free air convection Plastic o o min. 100 3,000 100 -20 -25 20 typ. max. unit KHz VAC M + 71 3 + 85 95 o o C C %/ C o % RH mm INPUT SPECIFICATIONS Characteristics Rated input voltage Input voltage range Line frequency Inrush current Io nom Ta min ... Ta max, Io nom Vi nom, Io nom Io nom Vi : 115VAC Vi : 230VAC AC in DC in Conditions min. 100 90 120 47 typ. max. 240 265 370 63 10 18 unit VAC VAC VDC Hz A A www.chinfa.com 2008.08.19 sales@chinfa.com DRA10 SERIES IND. CONT. EQ. SPECIFICATION All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed OUTPUT SPECIFICATIONS Characteristics Output voltage accuracy Minimum load Line regulation Load regulation Transient recovery time Temperature coefficient Ripple & noise Hold up time Voltage trim range DC ON indicator threshold at start up Vi nom Io nom, Vi min ...Vi max Vi nom, Io min ...Io nom 50% load, step changed Vi nom, Io min Vi nom, Io nom,BW = 20MHz Io nom Vi nom, Io nom Vi nom, Io nom Vi = 115VAC Vi = 230VAC 5V ...15V models 24V model 5V model 12V model 15V model 24V model DC LOW indicator threshold after start up Vi nom, Io nom 5V model 12V model 15V model 24V model Efficiency Vi nom, Io nom, Po / Pi 25 100 - 10 - 10 4.5 10.8 13.5 21.6 3.75 9 11.25 18 Up to 76%, See model list 4.5 10.8 13.5 21.6 + 15 + 20 300 0.02 50 o Conditions Vi nom, Io min ...Io nom min. 0 typ. max. 1 1 2 unit % % % % S %/C mV ms ms % % VDC VDC VDC VDC VDC VDC VDC VDC CONTROL AND PROTECTION Characteristics Input fuse Rated over load protection Over voltage protection Output short circuit Vi nom Vi nom, Io nom Vi nom, Io nom 110 125 Hiccup mode Conditions min. typ. max. 145 145 unit % % T2A / 250VAC internal APPROVALS AND STANDARDS UL / cUL TUV CE UL508 Listed UL60950-1, UL1310 Class 2 Power Supply Recognized EN60950-1 EN61000-6-3 / EN55022 Class B, EN61000-3-2 , EN61000-3-3 EN61000-6-2 / EN55024 / EN61204-3 CIRCUIT SCHEMATIC Block diagram for DRA10 series L Fuse Line Filter N Y Inrush Current Switching Limiter and Device Rectifier Vo + Rectifier Current Detection Vo - Control Opto Isolation Opto Isolation Reference & Error Amp. Over Voltage Detection Output Level Detection Vout ADJ. www.chinfa.com 2008.08.19 DC ON (Green LED) DC LOW (Red LED) sales@chinfa.com DRA10 SERIES IND. CONT. EQ. MECHANISM & PIN CONFIGURATION mm [inch] 22.5 [0.89] 115 [4.53] 21 CONSTRUCTION Easy snap-on mounting onto the DIN-Rail (TS35/7.5 or TS35/15), unit sits safely and firmly on the rail; no tools required even to remove V- V+ DC Output LO ON INSTALLATION Ventilation / Cooling Normal convection All sides 25mm free space For cooling recommended Connector size range Solid:0.2-2.0mm2(AWG24-14) (use copper conductors only) 90.0 [3.60] Vout ADJ. NL 345 PHYSICAL CHARACTERISTICS CASE SIZE CASE MATERIAL WEIGHT 90 x 22.5 x 115 mm 3.6 x 0.89 x 4.53 inches Plastic 120 g PIN ASSIGNMENT PIN NO. OUT 1 2 3 4 5 Designation V+ VN L ON LO Vout ADJ. Description Positive output terminal Negative output terminal Ground this terminal to minimize high-frequency emissions Input terminals (neutral conductor, no polarity at DC input) Input terminals (phase conductor, no polarity at DC input) Operation indicator LED DC LOW indicator LED Trimmer- potentiometer for Vout adjustment DERATING 100 Power out [ % ] 70 0 -20 Temperature [ oC ] www.chinfa.com 2008.08.19 OTHER IN 61 71 sales@chinfa.com |
Price & Availability of DRA10-05
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |