Bus Converter EUS20-120 Model Features: 48 Vin, Isolated, 4:1 Fixed Conversion Ratio 250 Watt Output at 48 Vin, 55 C, 200 LFM 200 Watt Output at 38 Vin, 55 C, 200 LFM Industry Standard 1/8 Brick Footprint Remote Enable (Primary Side, Positive or Negative) Over-temperature and Over Current Protection Direct Parallel Operation for Higher Power RoHS Compliant Table 1 Input Characteristics Input Voltage Operating Range Input Voltage Absolute Maximum Input Undervoltage Lockout Notes & Conditions Min 36 36 34 2 55 56 2 6.4 98 6 25 0.2 -0.1 2.4 2.4 -0.1 Table 2 Output Characteristics Output Voltage Set Point (Vo=Vin/4 +0/-0.5%) Output Load Regulation Output Voltage Total Regulation Output Ripple Voltage & Noise Output Current Operating Range Output Current Share Accuracy Efficiency Turn-On Time Start-up Inhibit Time Transient Response Maximum Output Capacitance Notes & Conditions Vin = 48.0 V, Io = 0 A Io = 0 to 20 A Vin = 36 to 55 V, Io = 0 to 20 A, Vin = 42 to 53 V, Io = 0 to 23 A, 20 MHz Bandwidth 0 Percent deviation from ideal (9) Vin = 48 V, Io = 20 A Vin present: Enable to 90% Vout Enabled: Vin applied to 90% Vout 25% step, 0.1A/s, Vo Recovery Time < 10 95.5 10 80 160 100 2000 Min 11.94 8.3 9.7 90 Typ. 11.98 0.7 Max 12.0 13.75 13.25 150 20 Units Vdc V Vdc Vdc mV p-p A % % mS mS mV s F 0.8 5.0 5.0 0.8 57 58 Typ. 48 Max 55 60 37.5 35.5 Units Vdc Vdc Vdc Vdc Vdc Vdc Vdc Vdc Adc mA mA mA p-p 2 As Vdc Vdc Vdc Vdc Input Overvoltage Lockout Maximum Input Current No-Load Input Current Disabled Input Current Input Reflected Ripple Current Inrush Current Transient Enable - Negative Logic Version Internal 10 K pull-up to 5 V. Enable - Positive Logic Version Internal 100 K pull-down to GND. Turn-on Threshold Turn-off Threshold Hysteresis Voltage Turn-on Threshold Turn-off Threshold Hysteresis Voltage Steady-State (26 A out) Enabled state, no load (48 Vin) Disabled state (48 Vin) Note (10) On State range Off State range On State range Off State range Technical enquiries email: sales@murata-ps.com tel: +508 339 3000 , 1 EUS20-120-6200921520.B01 18/04/08 Murata Power Solutions BUS CONVERTER EUS20-120 Model Table 1 Protection Characteristics Output Over-Current Shutdown Over Temperature Shutdown (5) Over Temperature Restart Hysteresis Notes & Conditions 0 Non-Latching Re-start rate Non-Latching Min 24 Typ. 25 75 125 10 Max 27 130 Units A msec C C Table 2 General Specifications Isolation Voltage Isolation Resistance Storage Temperature Range Operating Temperature Range Thermal Measurement Location Temperature (7) Material Flammability MTBF Notes & Conditions 0 Input to Output Input to Output Non-condensing Ambient (7) See mechanical drawing for location UL 94V-0 Calculated (Bellcore TR-332) Demonstrated 2.28"L x 0.9"W x 0.48"H (max) (57.9L x 22.9W x 12.19H mm max) Min 2250 10 -40 -40 Typ. Max Units Vdc Mohm C C C x10 Hrs 6 x10 Hrs 6 125 100 120 2.7 2 Dimension Weight 30 grams Table 3 Standards Compliance UL/CSA 60950 EN60950 Notes & Conditions (6) Basic Insulation Certified by TUV Notes: Vin = 48Vdc, Ta = 25 C, Airflow = 200 LFM for all data unless otherwise noted. Output ripple voltage and noise is specified when measured with a 10uF tantalum and a 1uF ceramic capacitor at the converter output pins. Transient response is specified without a capacitor at the output of the converter. Product operates with an external capacitance significantly greater than specified. However, for values higher than 2000uF please contact C&D representative. Thermal shutdown is monitored at the Thermal Measurement Location (TML). See `Mechanical Information' on page 3 for TML location. See `Safety Considerations' shown on last page. De-rating curves are conducted in a controlled environment. End application testing is required to ensure the Thermal Measurement Location temperature is below the maximum specified. Recommended airflow direction is from pin 1 to pin 3, or 3 to 1 (transverse airflow). Current share accuracy is optimized when the source and load impedance presented to each converter is equal. Input Reflected Ripple is specified when measured with a 12uH source inductance. EUS20-120-6200921520.B01 18/04/08 2 Murata Power Solutions Mechanical Information BUS CONVERTER EUS20-120 Model Figure 1 Pin Assignment Table 4 Pin # 1 2 3 4 5 Pin Name Vi(+) En Vi(-) Vo(-) Vo(+) Function Positive Input Voltage Input Enable / Disable Negative Input Voltage Negative Output Voltage Positive Output Voltage Referenced to Vi(-). Positive Logic: Floating = Enabled Negative Logic: Floating = Disabled Notes & Conditions EUS20-120-6200921520.B01 18/04/08 3 Murata Power Solutions BUS CONVERTER EUS20-120 Model Efficiency Curves Efficiency (%) vs. Iout (A) and Vin (V) 97% 96% 95% 94% 93% 92% 91% 90% 2 4 6 8 10 12 14 16 18 20 22 24 55Vin 48Vin 42Vin 38Vin Output Voltage vs. Current Vo (V) vs. Io (A) and Vin (V) 14 13 12 11 10 9 55 Vin 8 7 6 0 2 4 6 8 10 12 14 16 18 20 22 24 48 Vin 42 Vin 38 Vin EUS20-120-6200921520.B01 18/04/08 4 Murata Power Solutions BUS CONVERTER EUS20-120 Model Airflow from pin 3 to pin 1 Iout (A) vs. Tamb (C) and Air Flow (LFM) at 42 Vin Thermal Derating Curves (Transverse) TTML=120C Iout (A) vs. Tamb (C) and Air Flow (LFM) at 38 Vin 24 22 20 18 16 14 12 10 8 6 4 2 0 25 100 LFM 200 LFM 300 LFM 400 LFM 24 22 20 18 16 14 12 10 8 6 4 2 0 45 55 65 75 85 25 100 LFM 200 LFM 300 LFM 400 LFM 35 35 45 55 65 75 85 Iout (A) vs. Tamb (C) and Air Flow (LFM) at 48 Vin 24 22 20 18 16 14 12 10 8 6 4 2 0 25 35 45 55 65 75 85 400 LFM 100 LFM 200 LFM 300 LFM Iout (A) vs. Tamb (C) and Air Flow (LFM) at 55 Vin 24 22 20 18 16 14 12 10 8 6 4 2 0 25 35 45 55 65 75 85 100 LFM 200 LFM 300 LFM 400 LFM Output Power Curves at 200 LFM as a function of Ambient Temperature and Vin 350 300 250 200 150 100 50 25 30 35 40 45 50 55 60 65 70 75 80 85 Vin = 38 VDC Vin = 42 VDC Vin = 48 VDC Vin = 55 VDC Ambient Temperature EUS20-120-6200921520.B01 18/04/08 5 Murata Power Solutions Turn-on from Vin (Enable On) BUS CONVERTER EUS20-120 Model Turn-on from Enable (Vin present) Figure 9 Ch1: Vin; Ch2: Vout Vin=48V, Io=20A, Co=1000uF Figure 10 C3: Enable; Ch2: Vout Vin=48V, Io=20A, Co=1000uF Output Ripple/Noise Thermal Image 140.0C 140 120 SP01: 83.4 SP03: 78.0 SP02: 77.0 SP05: 91.2 SP04: 86.7 100 80 60 40 40.0C Figure 11 Vin=48V, Io=20A Vripple = 114 mVpp Figure 12 Vi=48 V, Iout=20 A, 200 LFM bottom side EUS20-120-6200921520.B01 18/04/08 6 Safety Considerations The EUS series of converters are certified to the standards listed in the `Standards Compliance' section in the table above. If this product is built into information technology equipment, the installation must comply with the above standard. An external input fuse (10 A recommended), must be used to meet the above requirements. The output of the converter [Vo(+)/Vo(-)] is considered to remain within SELV limits when the input to the converter meets SELV or TNV-2 requirements. The converters and materials meet UL 94V-0 flammability ratings. Figure 13 Ordering Information 7 EUS20-120-6200921520.B01 18/04/08 |
Price & Availability of EUS20-120-NHARVC
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |