![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
s Embedded Power for Business-Critical Continuity Intelligent VS Power Up to 4920 Watts Font: Minion Bold for VS Minion italic for i ; size for each is the same Created on Mac TM Rev. 1.22.09_145 IVS Series 1 of 11 Color: "i" 100% Blue, 50% Magenta, 0% Yellow, 0% Black "VS" - 100% Black Total Power: Up to 4920 Watts Input Voltage: 85-264Vdc 120-300Vdc # of Outputs: Up to 24 Special Features *FullmedicalEN60601approval *IntelligentI2C control *Voltageadjustmentonalloutputs (manualorI2C) *Configurableinputandoutput OKsignalsandindicators *Configurableinhibit/enable *ConfigurableoutputUP/DOWN sequencing *Highpowerdensity(12W/cu-in) *Intelligentfan(speedcontrol/ fault status) *uPcontrolledPFCinputwith activeInrushprotection *I2Cmonitorofvoltage,current, and temperature *Programmablevoltage,current limit,inhibit/enablethroughI2C *Optionalextendedhold-up module (SEMIF47compliance) *Increasedpowerdensityto150% *Optionalconformalcoating *Industrialtemprange(-40C to 70 C) *UsesstandardiMP modules *Fieldupgradeablefirmware *RoHScompliant Electrical Specifications Input Inputrange: IVS1&IVS3 90-264Vac1O;120-300Vdc IVS6&IVS8 170-264Vac3O IVS8H 480Vacnominal3O 380Vacnominal3Oderateto3800Wmax. Frequency: 47-440Hz Inrushcurrent: Efficiency: PowerFactor: Turn-ontime: EMIFilter: Leakagecurrent: RadiatedEMI: Holdoverstorage: 40Apeakmaximum(softstart) Upto85%@fullcaseload 0.99typ.meetsEN61000-3-2 ACon1.5sectypical,inhibit/enable150mstypicalProgrammable; 50msinternalturn-ondelay(DualOutputonly) CISPR22/EN55022Level"B" 500Amax.@240Vac;47-63Hz CISPR22/EN55022Level"B" 10msminimum(independentofinputVac)additional20mSEC holdoverstoragewithoptionalHUPmodule (SEMIF47compatible) > 5msearlywarningminutesbeforeoutputsloseregulationFullcycle ridethru(50Hz).Programmable MeetsEN61000-3-2 MeetsEN60950andEN60601 3years ACOK: Harmonicdistortion: Isolation: Warranty: Globalinhibit/enable: TTL,Logic"1"andLogic"0";configurable Safety UL CSA VDE BABT * CB * CE * * * * UL60950/UL2601 CSA22.2No.234Level5 EN60950/EN60601-1 CompliancetoEN60950/ EN60601BS7002 Certificate and report MarktoLVD Embedded Power for Business-Critical Continuity Output Adjustment range:* Margining: Overallregulation: Ripple: 10%minimumalloutputs(manual) (fullmoduleadjustmentrangeusingI2C) 4-6%nominalanalog(singleoutputmoduleonly) 0.4%or20mVmax.(1500Wmodules1%max.) RMS:0.1%or10mV,whicheverisgreater Pk-Pk:1.0%or50mV,whicheverisgreater Bandwidthlimitedto20MHz <2%or100mV,with25%loadstep Towithin1%in<300sec ConfigurablethroughI2C(calibrationrequired).Singleoutputmoduleand mainoutputofthedualoutputmodule105-120%ofratedoutputcurrent. Auxoutputofdualoutputmodule105-140%ofratedoutputcurrent. SpecialprogrammableOCPdelayon1500Wmodulefrom100mSecto 25.5 secondswithshutdownfeatures. Protectedforcontinuousshort-circuit. Recoveryisautomaticuponremovalofshort (Shutdownmodeon1500Wmodule). ConfigurablethroughI2C 2-5.5V122-134%;6-60V110-120% 2-6V122-134%;8-28V110-120% Noovervoltageprotectionprovided ConfigurablethroughI2C Alloutputsdisabledwheninternaltempexceedssafeoperatingrange. >5mswarning(ACOKsignal)beforeshutdown U pto0.5Vtotaldrop(notavailableontripleoutputmodule) Currentsharetowithin2%oftotalratedcurrent Rev. 1.22.09_145 IVS Series 2 of 11 Dynamicresponse: Recoverytime: Overcurrent protection:** Short-circuitprotection: Overvoltage protection:* Singleoutputmodule: Dualoutputmodule: Tripleoutputmodule: Thermal protection:* Remotesense: Singlewireparallel: DCOK:* +/-5%ofnominal. onfigurablethroughI2C C Minimumload: Notrequired Housekeepingbiasvoltage: 5Vdc@1.0Amax.presentwheneverACinputisapplied Module inhibit:* ConfiguredandcontrolledthroughI2C Output/Outputisolation: >1Megohm,500V * CanbecontrolledviaI2C ** ControlledviaI2Cbutrequiresloadcalibration(except1500Wmodule) EnvironmentalSpecifications -40to70Cambient.Derateeachoutput2.5%perdegreefrom50to70C. ( -20 C start up) Storagetemperature: -40Cto85C Electromagneticsusceptibility: DesignedtomeetEN61000-4;-2,-3,-4,-5,-6,-8,-11Level3 Humidity: Vibration: MTBFdemonstrated: Operating;non-condensing10%to95%RH IEC68-2-6tothelevelsofIEC721-3-2 >550,000hoursatfullload,220Vacand25Cambientconditions Operatingtemperature: Embedded Power for Business-Critical Continuity Output Module Line-up Module Code Module Type Maxoutputpower Maxoutputcurrent Outputvoltagesavailable* Standardvoltageincrements Remotesense Remotemargin V-Program-I2C Control ActiveCurrentShare ModuleInhibit-I2C Control ModuleInhibit-Analog Overvoltage/Overcurrent protection Minimum load required Slots occupied in any IVS case 1 Single 210W 35A 2-60V 25 Yes Yes Yes Yes Yes Yes Yes No 1 2 Single 360W 60A 2-60V 25 Yes Yes Yes Yes Yes Yes Yes No 2 3 Single 750W 150A 2-60V 25 Yes Yes Yes Yes Yes Yes Yes No 3 5 Single 1500W 140A 6-60V 18 Yes Yes Yes Yes Yes Yes Yes No 4 Yes No Yes Yes Yes Yes Yes No 1 4 Dual 144W 10A 6-15,24-28;6-15;6-15;6-15; 2-6;2-6,2-6;24-28,24-28; 24-28;2-6 16 Yes No Yes No Yes No Yes No -- Triple 36W 2A 8-15,8-15,2-6; 8-15,8-15,8-15; 8-15,8-15,18-28; 8-15,18-28,2-6 18 No No No No Yes No Yes No 1 Rev. 1.22.09_145 IVS Series of 11 Single OutputModuleVoltage/Current* Voltage Voltage Code SingleOutputModuleCode DualOutput** Triple Output 1 2V 2.2V 3V 3.3V 5V 5.2V 5.5V 6.0V 8.0V 10V 11V 12V 14V 15V 18V 20V 24V 28V 30V 33V 36V 42V 48V 54V 60V Special Special Special A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Z Z 35A 35A 35A 35A 35A 35A 34A 23A 20 A 18A 17A 17A 14A 14A 11A 10.5A 8.5A 6.7A 6.5A 6.2A 5.8A 4.2 A 4.0 A 3.7A 3.5A 35A 35A 20 A 2 3 5 4 4 10A 10A 10A 10A 10A 10A 10A 10A 4A 4A 4A 4A 4A 4A -- -- 2A 2A -- -- -- -- -- -- -- 10A 10A 8A -- -- -- -- -- -- -- -- 1A 1A 1A 1A 1A 1A -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 1A 1A 1A 1A 1A 1A 0.5A 0.5A 0.5A 0.5A -- -- -- -- -- -- -- 2A 2A 2A 2A 2A 2A 2A 2A 1A 1A 1A 1A 1A 1A 0.5A 0.5A 0.5A 0.5A -- -- -- -- -- -- -- I2C Adjustment Ranges*** 210W 750W 360W 1500W Dual Triple 60A 150A -- 10A 60A 150A -- 10A 60A 150A -- 10A 60A 150A -- 10A 60A 150A -- 10A 60A 144A -- 10A 58A 136A -- 10A 42 A 97.5A 140A 10A 36A 84.4 A 140A 10A 32A 75A 140A 10A 31A 68A 136.3A 10A 30A 62.5A 125A 10A 21A 53.5A 107A 9 A 100A 8 A 20 A 50A 19A 41.6A 83.3A -- 18A 37.5A 75A -- 15A 30A 62.5A 4 A 11A 26.8A 53.5A 3A 11A 25A 50A -- 10.9A 22.7A 35.8A -- 10A 20.8 A 35.8A -- 7.5A 16A 35.7A -- 7.5A 15.6A 31.2A -- 6.0A 13.9A 27.7A -- 6.0A 12.5A 25A -- 60A 60A 36A 150A 150A 80 A -- -- 140A -- -- -- 1.8-2.2 2.0 - 2.4 2.7-3.3 3.0-3.6 4.5-5.5 4.7-5.7 5.0-6.1 5.4-6.6 7.2-8.8 9.0-11.0 9.9-12.1 10.8-13.2 12.6-15.4 13.5-16.5 16.2-19.8 18.0-22.0 21.6-26.4 25.2-30.8 27.0-33.0 29.7-36.3 32.4-39.6 37.8-46.2 43.2-52.8 48.6-59.4 54.0-66.0 2.3-2.6 3.7-4.4 6.7-7.1 Contact Factory 144W 36W *Note:Incrementsofcurrentnotshowncanbeachievedbyparallelingmodules (addcurrentsofeachmoduleselected). **Totaloutputpowerondualmodelmustnotexceed144W. ***Forsingleoutputmodulesonly. Embedded Power for Business-Critical Continuity OrderingInformation Samplebelowis3210Wcasewith12V@125A;24V@8.5A;5V@60A;12V@10Aand12V@4A;withnooptions. Module/Voltage/Option Codes First - Module Code Second-VoltageCode Third-OptionCode Rev. 1.22.09_145 IVS Series 4 of 11 Case Size Case Option Codes Software Code Hardware Code IVS1 Case Size (mm) 1-Phase Input 1 = 5"x5"x11";1500W-3210W,9Slots (127x127x279.4) 3 = 5"x8"x11";1800W-4500W,14Slots (127x203.2x279.4) 3-Phase Input 6 = 5"x5"x11";3120W,9Slots (127x127x279.4) 8 = 5"x8"x11";4920W,14Slots (127x203.2x279.4) 8H=5"x8"x11";4920W,14Slots (127x203.2x279.4) - 5L1 - 1Q1 - 2EO - 4LL0 Module Codes Module/voltage/optioncodes ModuleCodes: (None)=36WtripleO/P(1slot) 1=210WsingleO/P(1slot) 2=360WsingleO/P(2slot) 3=750WsingleO/P(3slot) 5=1500WsingleO/P(slot4) 4=144WdualO/P(1slot) HUP=Extra30mShold-up(1slot) Voltage Codes: SeeOutputModuleVoltage/Current tableabove Option Codes: 0 =Standard 1 =Moduleenable 2 =Constantcurrent 3 =1&2combined 4 =Setforuseinstandard (non-intelligentcase) 5 =Shutdownmodefor1500W 6 =1&5combined 7-9 Future 00 Case Option Codes FirstDigit 0-9=Parallelcode (See parallel codes table below) SecondDigit 0=Nooptions 1=Reverseair 2=Notused 3=Globalenable 4=FanOffw/inhibit 5=Opt1+Opt3 6=Opt1+Opt4 7=Opt3+Opt4 8=Opt1+3+4 9=Future - A Software code usedforconfigurationchange."A" is standard - ### Factory assembled forhardwareof firmware mods. OrderingNote: 1.USBtoI2C module order code 73-769-001 Parallel Code 1 2 3 4 SlotNo. Diagram 1&2 2&3 3&4 4&5 AC 9 8 7 6 54321 AC 9 8 7 6 54321 AC 9 8 7 6 54321 AC 9 8 7 6 54321 IVS1,6 PossibleConfigurations 210210;210144;144144 360360;360210;360144;+above 750360;750210;750144;210210; 210144;144144 1500210;1500144;210210;210144; 144144;360210;360144 750210210;750210144;750144144 15001500;1500750 1500210210;1500210144;1500144 144 750750 15001500;1500360;1500144 750210&750210 750,360,750 AC 14 13 12 11 10 9 87654321 AC 14 13 12 11 10 9 IVS3,8,8H Diagram AC 14 13 12 11 10 9 87654321 AC 14 13 12 11 10 9 87654321 AC 14 13 12 11 10 9 87654321 AC 14 13 12 11 10 9 87654321 PossibleConfigurations 210210;210144;144144 360360;360210;360144;+above 750750;750360;750210;750144; 210210;210144;144144 15001500;1500750;1500360;1500210; 1500144;210210;210144;144144;360 360;360210;360144 750210210;750210144;750144144 5 6 7 8 9 A C E F G 3,4,&5 4&6 4,5,&6 IVS1,6:3&6 IVS3,8,8H:4,5,&9 IVS1,6:1&6 IVS3,8,8H:4,5&9;12&13 IVS1,6:3&4;8&9 IVS3,8,8H:4&5;11&12 IVS1,6:3,4&6 IVS3,8,8H:6&7;3,4,11&12 IVS3,8,8H:3,4,11,&12 IVS3,8,8H:3&4;11&12 IVS3,8,8H:3,4&9 AC 9 8 7 6 54321 AC 9 8 7 6 54321 AC 9 8 7 6 54321 AC 9 8 7 6 54321 AC 9 8 7 6 54321 AC 9 8 7 6 54321 AC 9 8 7 6 54321 AC 14 13 12 11 10 9 87654321 1500210210;1500210144;1500144144 150015001500;15001500750;15001500 360;15001500210;15001500144 150015001500360;150015001500210; 150015001500144 15001500&750750 750750360750750 750750750750 750360&750210;750750&750750 750750750 87654321 AC 14 13 12 11 10 9 87654321 AC 14 13 12 11 10 9 87654321 AC 14 13 12 11 10 9 87654321 AC 14 13 12 11 10 9 87654321 AC 14 13 12 11 10 9 87654321 AC 14 13 12 11 10 9 87654321 Embedded Power for Business-Critical Continuity IVSCaseSpecifications IVS1 and IVS6 S L O T 9 S L O T 5 S L O T 4 S L O T 8 S L O T 3 Rev. 1.22.09_145 IVS Series 5 of 11 Input 90-264Vac 170-264Vac S L O T 7 S L O T 2 S L O T 6 S L O T 1 IVS1= 5"x5"x11" 1500Wmax. 3210Wmax. (127x127x279.4) 9availableslots IVS6= 5"x5"x11" N/A (127x127x279.4) 9availableslots 3-phaseonly 170-264Vac 3210Wmax. IVS3, IVS8, and IVS8H S L O T 14 S L O T 8 S L O T 7 S L O T 6 S L O T 13 S L O T 5 S L O T 12 S L O T 4 S L O T 11 S L O T 3 S L O T 10 S L O T 2 S L O T 9 S L O T 1 IVS3 = 5"x8"x11" 1800Wmax. 4500Wmax. (127x203.2x279.4) 14availableslots IVS8= 5"x8"x11" N/A (127x203.2x279.4) 1 14availableslots 2 IVS8H=5"x8"x11" N/A (127x203.2x279.4) 3 14availableslots 170-264Vac 4920Wmax. 380Vac Input 90-264Vac 170-264Vac N ~ 3800Wmax. 480Vac 4920Wmax. Figure 1. AC Input Pin Connectors Figure 1. AC Input 1 2 3 N ACInput PinNo. L L L SinglePhase Function AC neutral ACline(hot) 1 N 3Phase Line1 1 Line 2 Line3 Figure 2. Connector J1 PFCInputConnector(controlandsignals) Function InputACOK-"emitter" InputACOK-"collector" GlobalDCOK-"emitter" GlobalDCOK-"collector" Noconnection Globalinhibit/optionalenablelogic"0" Globalinhibit/optionalenablelogic"1" Globalinhibit/optionalenablereturn +5VSBhousekeeping +5VSBhousekeepingreturn 1 2 3 4 ~ 1 2 3 1 IVS1,IVS3 L L IVS6 L 4 2 2 Chassis(earth) ground 3 3 Chassis(earth) 4 ~ 2 3 ground IVS8,IVS8H 4 3 2 1 PinNo. 1 1 5 2 6 10 3 Mateswith Connector J1 Figure 2. 4 Molex90142-0010Housing 90119-2110Pin 5 6 7 8 9 10 I2C Bus Output Connector Figure 3. Connector J2 Mateswith Landwin 2050S1000housing 2053T011Ppin PinNo. 1 2 3 4 5 6 7 8 9 10 Function Noconnection Noconnection Noconnection Serialclocksignal(SCL) Serialdatasignal(SDA) Address bit 0 (A0) Addressbit1(A1) Address bit 2 (A2) Secondaryreturn(GND) 5VCCexternalbus(5VCCbus) Embedded Power for Business-Critical Continuity iMP Modules DC-DCConverterOutputModules ControlSignalInformation,J1ControlConnector PinNo. 1 2 3 4 5 6 7 8 9 10 Function +RemoteSense singleordualo/pmain RemoteMargin/V.Program singleo/p MarginHigh N singleo/p 1 -RemoteSense/MarginLow singleordualo/pmain 2 Spare 3 Module,IsolatedInhibit singleordualo/p ModuleInhibitreturn singleordualo/p CurrentShare(SWP) singleordualo/pmain +RemoteSenseV2 dualo/p,singleisspare Figure 1. AC Input -RemoteSenseV2 dualo/p,singleisspare *Note:AlliMPmoduleshaveagreenDCOKLED. (exceptfor36Wmodule) Rev. 1.22.09_145 IVS Series of 11 Single210Watt .44" (11.2) 2X V+ (12.1) .48" ~ M4X8 SCREWS WITH CONICAL WASHER V- 1.38" (35.1) V ADJ .44" (11.4) PIN 1 DC OUTPUT CONNECTOR .32" (8.1) Figure 4. Connector J1 1 6 5 10 Mateswith Connector J1 Figure 2. Molex90142-0010Housing 90119-2110Pin Single360Watt .63" .33" (16.0) (8.5) Single750Watt V+ .59" (15.0) .63" (16.0) V+ Single1500Watt .48" (12.1) (2X) M 4 X 8 SCREWS WITH CONICAL WASHER .61"(15.6) (2X) 1.24"(11.0) (2X) .44" (11.0) VPIN 1 1.38" (35.2) (2X) .44" (11.4) V ADJ DC OUTPUT CONNECTOR .32" (8.1) .32" (8.1) PI D CO C O NN UTP EC UT TO R N 1 V AD J M (4 4X8 X) S C VRE W S V- V+ Dual144Watt .46 (11.7) (4X) V1 V2 + V2 M3X8 SCREWS WITH SPRING WASHER (4X) V2 ADJ V1 ADJ PIN 1 V1 + Triple36Watt V1 ADJ V2 ADJ V1+ V2+ V3+ V3 ADJ V1 + V1V2V3- V1 V2 + V2 V3 + V3 - .30 (7.5)(3X) 1.17 (29.7) .42 (10.7) .32 (8.1) Mateswith Molex09-91-0600Housing 26-60-5060Pin Embedded Power for Business-Critical Continuity IVSSeries IVS1(1500/3210 WattsMax) 5-InchCaseSize:IVS1:5"x5"x11"(127mmx127mmx279.4mm) Weight:IVS1Case:6.2lbs.*1500WSingle:2.0lbs.*750WSingle:1.6lbs. *360WSingle:1.0lb.*210WSingle:0.6lb.*144WDual:0.6lb. Rev. 1.22.09_145 IVS Series 7 of 11 REVERSE AIRFLOW DIRECTION NORMAL AIRFLOW DIRECTION 127.0 0.5 B B 279.40 1.27 AC INPUT CONNECTOR L N PE 127.0 0.9 101.6 0.9 A 127.0 0.5 63.5 FAN 92 X 92 X 38mm 127.0 0.9 USB PROGRAMMING CONNECTOR OPTION C 12.7 19.1 171.5 M4 MTG HOLES 4 PL SELV CONTROL CONNECTOR I2C C CONNECTOR 13.5 33.5 57.4 DC OK LED AC OK LED 65.5 11.6 12.0 C OUTPUT MODULE AREA "MOUNTING HOLES DIMENSIONS IDENTICAL ON BOTH SIDES" 171.45 29.05 5.00 12.70 B 114.30 22.80 19.05 171.45 A Notes 1. Input:Barriertype.ThreeNo.6-32B.H.screws(0.375"centers).Maxtorque:6in-lbs.(0.67N-m). 2. Controlconnectors:(J1)10positionhousing,goldplatedcontacts.MateswithMolex90142-0010housingwith90119-2110crimpcontacts(MolexC-GridIIISeries). Connectorkitincludesmatingconnectorand10pins,Astecpart#70-841-004.(J2)10positionhousing(Landwin2051P1000T).Mateswithhousing2050S1000 (Landwin)with2053T011P(Landwin)pins. 3. Chassismaterial:aluminumwithchemicalfilmcoating(conductive). 4. Alldimensionsareinmillimetersandinches,andaretypical. 5. Customermounting-3sidesM4,bottomalsoincludes8-32mountingholes.Max.penetrationis0.155"(4.0mm).Max.torque:5in-lbs.(0.57N-m). 6. Outputmoduleconnections:AllsingleO/PmodulesareM4x8mmscrews.Max.torque:10in-lbs.(1.13N-m). DualO/PmoduleisM3x8mmscrews.Max.torque:5in-lbs.(0.57N-m). Embedded Power for Business-Critical Continuity IVSSeries IVS3(1800/4500 WattsMax) 8-InchCaseSize:IVS3:5"x8"x11"(127mmx203.2mmx279.4mm) Weight:IVS3Case:9.0lbs.*1500WSingle2.0lbs.*750WSingle:1.6lbs. *360WSingle:1.0lb.*210WSingle:0.6lb.*144WDual:0.6lb. Rev. 1.22.09_145 IVS Series of 11 REVERSE AIRFLOW DIRECTION NORMAL AIRFLOW DIRECTION B 13 14 12 11 10 9 B 203.20.5 98 279.41.27 A A SL AC INPUT CONNECTOR OT OT OT OT OT SL SL SL SL SL OT 52.6 FAN 80 X 80 X 38mm 101.6 0.9 12.7 11.6 OUTPUT MODULE AREA C 7 5 8 6 4 3 2 1 SELV CONTROL CONNECTOR C I2C 42 61.2 81.5 DC OK LED 65.5 USB PROGRAMMING CONNECTOR OPTION 1270.9 C OT OT OT SL SL SL SL SL SL SL SL 171.45 19.1 M4 MTG HOLES 4 PL AC OK LED OT OT OT OT OT A "MOUNTING HOLES DIMENSIONS IDENTICAL ON BOTH SIDES #8-32 MTG HOLES 5PL MARKED "A" 6, 7 REF 14.4 29.1 171.5 B B A B A 173.3 149.4 12.7 B A B A B A 16.2 19.1 171.5 M4 MTG HOLES 5 PL MARKED "B" A Notes 1. Input:Barriertype.ThreeM4screws(0.512"centers).Maxtorque:7in-lbs.(0.79N-m). 2. Controlconnectors:(J1)10positionhousing,goldplatedcontacts.MateswithMolex90142-0010housingwith90119-2110crimpcontacts(MolexC-GridIIISeries). Connectorkitincludesmatingconnectorand10pins,Astecpart#70-841-004.(J2)10positionhousing(Landwin2051P1000T).Mateswithhousing2050S1000 (Landwin)with2053T011P(Landwin)pins. 3. Chassismaterial:aluminumwithchemicalfilmcoating(conductive). 4. Alldimensionsareinmillimetersandinches,andaretypical. 5. Customermounting-3sidesM4,bottomalsoincludes8-32mountingholes.Max.penetrationis0.155"(4.0mm).Max.torque:5in-lbs.(0.57N-m). 6. Outputmoduleconnections:AllsingleO/PmodulesareM4x8mmscrews.Max.torque:10in-lbs.(1.13N-m). DualO/PmoduleisM3x8mmscrews.Max.torque:5in-lbs.(0.57N-m). 177.8 Embedded Power for Business-Critical Continuity IVSSeries IVS6(3210 WattsMax) 5-InchCaseSize:IVS6:5"x5"x11"(127mmx127mmx279.4mm) Weight:IVS6Case:6.0lbs.*1500WSingle2.0lbs. *750WSingle:1.6lbs.*360WSingle:1.0lb. *210WSingle:0.6lb.*144WDual:0.6lb. Rev. 1.22.09_145 IVS Series 9 of 11 279.41.0 5.00.5 NORMAL AIRFLOW DIRECTION REVERSE AIRFLOW DIRECTION 293.01.2 20.30.6 127.00.5 63.5 INTERNAL FUSES 15A/250V GND SLOT 7 SLOT 8 12.60.6 101.60.9 (2X) 12.7 (2X) I2C CONNECTOR SELV CONTROL CONNECTOR 13.5 AC OK LED DC OK LED 12.7 (2X) USB PROGRAMMING CONNECTOR OPTION 65.5 SLOT 3 SLOT 4 SLOT 2 SLOT 5 SLOT 1 11.6 (2X) 101.60.9 (2X) L1 L2 L3 SLOT 9 SLOT 6 AC INPUT CONNECTOR L1 L2 L3 127.00.9 33.5 57.4 FOR M4 SCREW (4X) (FOR SYSTEM MOUNTING) 19.1 (2X) 171.5 (2X) 171.5 (2X) 19.1 (2X) 12.0 171.5 (2X) 19.1 (2X) 12.7 (4X) FOR M4 SCREW (4X) (FOR SYSTEM MOUNTING) FOR #8-32 SCREW (4X) (SYSTEM MOUNTING) FOR M4 SCREW (4X) (FOR SYSTEM MOUNTING) 171.5 (2X) 29.1 (2X) Notes 1. Input:Barriertype.FourM3screws(0.325"centers).Maxtorque:6in-lbs.(0.67N-m). 2. Controlconnectors:(J1)10positionhousing,goldplatedcontacts.MateswithMolex90142-0010housingwith90119-2110crimpcontacts(MolexC-GridIIISeries). Connectorkitincludesmatingconnectorand10pins,Astecpart#70-841-004.(J2)10positionhousing(Landwin2051P1000T).Mateswithhousing2050S1000 (Landwin)with2053T011P(Landwin)pins. 3. Chassismaterial:aluminumwithchemicalfilmcoating(conductive). 4. Alldimensionsareinmillimetersandinches,andaretypical. 5. Customermounting-3sidesM4,bottomalsoincludes8-32mountingholes.Max.penetrationis0.155"(4.0mm).Max.torque:5in-lbs.(0.57N-m). 6. Outputmoduleconnections:AllsingleO/PmodulesareM4x8mmscrews.Max.torque:10in-lbs.(1.13N-m). DualO/PmoduleisM3x8mmscrews.Max.torque:5in-lbs.(0.57N-m). 12.7 (4X) Embedded Power for Business-Critical Continuity IVSSeries IVS8(4920 WattsMax) 8-InchCaseSize:IVS8:5"x8"x11"(127mmx203.2mmx279.4mm) Weight:IVS8Case:9.0lbs.*1500WSingle2.0lbs. *750WSingle:1.6lbs.*360WSingle:1.0lb. *210WSingle:0.6lb.*144WDual:0.6lb. Rev. 1.22.09_145 IVS Series 10 of 11 5.8 max (2x) NORMAL AIRFLOW DIRECTION REVERSE AIRFLOW DIRECTION 203.20.5 291.21 279.40.7 FOR M4 SCREW (4X) (SYSTEM MOUNTING) INTERNAL FUSES 10A/500V 12.7 (2X) 12.7 (2X) 127.00.7 12.7 (2X) 12.7 (2X) FOR M4 SCREW (4X) (SYSTEM MOUNTING) 19.1 (2X) 171.5 (2X) 171.5 (2X) 171.5 (2X) 19.1 (2X) 19.1 (2X) FOR M4 SCREW (4X) (SYSTEM MOUNTING) 12.7 (4X) FOR #8-32 SCREW (4X) (SYSTEM MOUNTING) 12.7 (4X) 171.5 (2X) 29.1 (2X) Notes 1. Input:Barriertype.ThreeM3.5screws(0.394"centers).Maxtorque:6in-lbs.(0.67N-m). 2. Controlconnectors:(J1)10positionhousing,goldplatedcontacts.MateswithMolex90142-0010housingwith90119-2110crimpcontacts(MolexC-GridIIISeries). Connectorkitincludesmatingconnectorand10pins,Astecpart#70-841-004.(J2)10positionhousing(Landwin2051P1000T).Mateswithhousing2050S1000 (Landwin)with2053T011P(Landwin)pins. 3. Chassismaterial:aluminumwithchemicalfilmcoating(conductive). 4. Alldimensionsareinmillimetersandinches,andaretypical. 5. Customermounting-3sidesM4,bottomalsoincludes8-32mountingholes.Max.penetrationis0.155"(4.0mm).Max.torque:5in-lbs.(0.57N-m). 6. Outputmoduleconnections:AllsingleO/PmodulesareM4x8mmscrews.Max.torque:10in-lbs.(1.13N-m). DualO/PmoduleisM3x8mmscrews.Max.torque:5in-lbs.(0.57N-m). s Embedded Power for Business-Critical Continuity Americas 5810VanAllenWay Carlsbad,CA92008 USA Telephone:+17609304600 Facsimile: +17609300698 Rev. 1.22.09_145 IVS Series 11 of 11 Europe (UK) Waterfront Business Park MerryHill,Dudley WestMidlands,DY51LX UnitedKingdom Telephone:+44(0)1384842211 Facsimile: +44(0)1384843355 Asia (HK) 14/F,LuPlaza 2WingYipStreet KwunTong,Kowloon HongKong Telephone:+85221763333 Facsimile: +85221763888 Forglobalcontact,visit: www.PowerConversion.com techsupport.embeddedpower @emerson.com Whileeveryprecautionhasbeentakentoensure accuracyandcompletenessinthisliterature,Emerson NetworkPowerassumesnoresponsibility,anddisclaims allliabilityfordamagesresultingfromuseofthis information or for any errors or omissions. Emerson Network Power. Thegloballeaderinenabling business-critical continuity. AC Power Connectivity DCPower EmbeddedComputing Embedded Power Monitoring Outside Plant PowerSwitching&Controls PrecisionCooling Racks&IntegratedCabinets Services SurgeProtection EmersonNetworkPower.com EmersonNetworkPowerandtheEmerson NetworkPowerlogoaretrademarksand servicemarksofEmersonElectricCo. (c)2008 Emerson Electric Co. |
Price & Availability of IVS
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |