![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Embedded Power for Business-Critical Continuity LPS200-M Series 250 Watts Total Power: Input Voltage: # of Outputs: 125-250Watts 90-264Vac Single Rev. 4.30.09_#98 LPS200-M Series of 3 Special Features * * * * * * * * * * * * * * MedicalandITEsafeties Activepowerfactorcorrection 3"x5"footprint Lessthan1Uhigh EN61000-3-2compliant Remotesense Powerfail Adjustablemainoutput Built-inClassBEMIfilter Overvoltageprotection Overloadprotection Thermaloverloadprotection Isolated12VFanoutput LPX80enclosureavailable Electrical Specifications Input Inputrange: Frequency: Inrushcurrent: Efficiency: EMI/RFI: Powerfactor: Safetyground leakagecurrent: 90-264Vac;120-300Vdc 47-63Hz 50Amax.,coldstart@25C 86%typicalatfullload FCCClassBconducted;CISPR22ClassBconducted; EN55022ClassBconducted;VDE0878PT3ClassBconducted 0.99typical 2 75uA@50/60Hz,264Vacinput Output Maximumpower: Adjustmentrange: Fanoutput: Hold-uptime: Overloadprotection: 125Wforconvection;250W(200WforLPS202-M)with30CFMforcedair 10%minimumonthemainoutputs 12V@1Aisolated,10% 16ms@250Wload,120Vacinput Shortcircuitprotectiononalloutputs.Caseoverloadprotected@110-160% aboverating Overvoltageprotection: 15-50%abovenominaloutput LogicalControl Powerfailure: Opencollectorlogicsignalgoeshigh100-500msecaftermainoutput;it goeslowatleast6msecbeforelossofregulation C ompensatesfor0.5Vleaddropmin.Willoperatewithoutremotesense connected.Reverseconnectionprotected. Safety * * * * * * TUV 60950,60601-1 UL 60950,60601-1 cULus 60950,60601-1 TUV 60950,60601-1 CB Certificate & report CE Mark(LVD) Remotesense: Embedded Power for Business-Critical Continuity EnvironmentalSpecifications Operatingtemperature: Storagetemperature: Electromagnetic susceptibility: Humidity: Vibration: MTBFdemonstrated: 0to50Cambientderateeachoutputas2.5%perdegreefrom50to70C.-20C start up -40Cto+85C DesignedtomeetEN61000-4; -2,-3,-4,-5,-6,-8,-11Level3 Operating;non-condensing10%to95%RH IEC68-2-6tothelevelsofIEC721-3-2 >550,000hoursatfullloadand25Cambientconditions Rev. 4.30.09_#98 LPS200-M Series 2 of 3 OrderingInformation Model Number LPS202-M LPS203-M LPS204-M LPS205-M LPS208-M Output Voltage 5V 12V 15V 24V 48V Minimum Load 0A 0A 0A 0A 0A MaximumLoadwith ConvectionCooling 20A 10.3A 8.3A 5.2A 2.6A MaximumLoadwith 30CFMForcedAir 40A 20.8A 16A 10.4A 5.2A PeakLoad Regulation2 44A 22A 18A 11.5A 5.8A 2% 2% 2% 2% 2% Ripple P/P(PARD)3 50mV 120mV 150mV 240mV 480mV 1. Peakcurrentlasting<30secondswithamaximum10%dutycycle. 2. At25Cincludinginitialtolerance,linevoltage,loadcurrentsandoutputvoltagesadjustedtofactorysettings. 3. Peak-to-peakwith20mHzbandwidthand10F(tantalumcapacitor)inparallelwitha0.1Fcapacitoratratedlinevoltageandloadranges. PinAssignments Connector LPS200-M SK1 Pin1 Pin3 SK2 TB-1 TB-2 SK3 Pin1 Pin 2 Pin3 Pin4 Pin 5 Pin6 Pin7 Pin8 Pin 9 Pin10 Neutral Line Common Mainoutput +V1Remotesense -V1Remotesense N/C N/C +Powerfail Common N/C Common +12VFan +12FanReturn(isolated) MatingConnectors ACInput(SK1): Molex09-50-8031(connector) PINS:08-52-0113 ACGround: Molex01-90020001 DCOutput (SK2): ControlSignals (SK3): Molex19141-0058/0063/0083 SpadelugbasedonCableAmpacity/AWG Molex90142-0010(USA) PINS:90119-2110or Amp:87977-3 PINS:87309-8 EmersonNetworkPowerConnectorKit#70-841-020,includesallofthe above. 1. Specificationssubjecttochangewithoutnotice. 2 . Alldimensionsininches(mm),toleranceis0.02"(0.5mm) 3. MountingholesMH1andMH2shouldbegroundedforEMIpurposes. 4. MountingholeMH1issafetygroundconnection. 5. Specificationsareforconvectionratingatfactorysettingsat115VAC input,25Cunlessotherwisestated. 6. Thispowersupplyrequiresmountingonmetal standoffs0.20"(5m)inheight. 7. Warranty:2years 8. Weight:0.75lb/0.34kg Embedded Power for Business-Critical Continuity MechanicalDrawing Americas 5810VanAllenWay Carlsbad,CA92008 USA Telephone:+17609304600 Facsimile: +17609300698 Rev. 4.30.09_#98 LPS200-M Series 3 of 3 3.00 (76.2) 2.55 (64.8) MH1 3 SK1 1 (4) 4 Places 0.15 Dia. Europe (UK) Waterfront Business Park MerryHill,Dudley WestMidlands,DY51LX UnitedKingdom Telephone:+44(0)1384842211 Facsimile: +44(0)1384843355 Asia (HK) 14/F,LuPlaza 2WingYipStreet KwunTong,Kowloon HongKong Telephone:+85221763333 Facsimile: +85221763888 4.55 (115.6) 5.00 (127.0) Forglobalcontact,visit: www.PowerConversion.com techsupport.embeddedpower @emerson.com Whileeveryprecautionhasbeentakentoensure accuracyandcompletenessinthisliterature,Emerson NetworkPowerassumesnoresponsibility,anddisclaims allliabilityfordamagesresultingfromuseofthis informationorforanyerrorsoromissions. Emerson Network Power. Thegloballeaderinenabling business-criticalcontinuity. ACPower Connectivity DCPower 2 SK2 1 SK3 EmbeddedComputing Embedded Power Monitoring OutsidePlant PowerSwitching&Controls 1.32 (33.6) MH2 PrecisionCooling Racks&IntegratedCabinets Services SurgeProtection EmersonNetworkPower.com EmersonNetworkPowerandtheEmerson NetworkPowerlogoaretrademarksand servicemarksofEmersonElectricCo. (c)2009EmersonElectricCo. 1 5 10 SK3 VR1 Output Voltage Adjust Pot 0.197" (5.0) Minimum Standoff Height |
Price & Availability of LPS200-M09
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |