If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Slim Connector-Terminal Block Conversion Units XW2D CSM_XW2D_DS_E_1_2 New Slim Connector-Terminal Block Conversion Units. * Mounting area reduced by 35% (in comparison with 40-pole XW2B Units) to contribute to downsizing control panels and automatic equipment. * Fallout prevention for terminal screws. * Round or forked crimp terminals can be used. * Mount to DIN Track or via screws. Unique DIN Track lock can maintain open status during DIN Track attachment and removal. * Terminal cover can be locked open. * Screw terminals are arranged by color in groups of five to simplify counting terminal numbers. Ordering Information Connectors Mounted Connector No. of poles 20 34 XG4A MIL Connectors Model XW2D-20G6 XW2D-34G6 XW2D-40G6 40 XW2D-40G6-RF *1 XW2D-40G6-RM *2 50 20 XG4C MIL Connectors 34 40 50 20 MR Sockets 34 50 20 MR Plugs 34 50 XW2D-50G6 XW2D-20C6 XW2D-34C6 XW2D-40C6 XW2D-50C6 XW2D-20X6 XW2D-34X6 XW2D-50X6 XW2D-20Y6 XW2D-34Y6 XW2D-50Y6 Dimension A 79 128 149 149 149 184 79 128 149 184 79 128 184 79 128 184 Dimension B 57 100 110 110 110 144 57 100 110 144 57 100 144 57 100 144 Mounted Connector model XG4A-2031 XG4A-3431 XG4A-4031 XG4A-4031 XG4A-4031 XG4A-5031 XG4C-2031 XG4C-3431 XG4C-4031 XG4C-5031 MR-20RFD2 *3 MR-34RFD2 *3 MR-50RFD2 *3 MR-20RMD2 *3 MR-34RMD2 *3 MR-50RMD2 *3 Cable Connector model XG4M-2030-T XG4M-3430-T XG4M-4030-T XG4M-4030-T XG4M-4030-T XG4M-5030-T XG4M-2030-U XG4M-3430-U XG4M-4030-U XG4M-5030-U MR-20M *3 MR-34M *3 MR-50M *3 MR-20F*3 MR-34F *3 MR-50F *3 *1. This model has built-in bleeder resistance and is used for inputs to Units with Fujitsu connectors, i.e., the CJ1W-ID231/-ID261/-MD261. *2. This model has built-in bleeder resistance and is used for inputs on Units with MIL connectors, i.e., the CJ1W-ID232/-ID262/-MD263/-MD563. *3. The MR Connector is made by Honda Tsushin Kogyo. Accessories (Order Separately) Connecting Cables for Connector-Terminal Block Conversion Units Refer to the XW2Z Datasheet. Ratings and Specifications Rated current Rated voltage Insulation resistance Dielectric strength 1A 125 VAC, 24 VDC 100 M min. (at 500 VDC) 500 VAC for 1 min (leakage current: 1 mA max.) Ambient operating tem0 to 55C perature 1 XW2D Dimensions XW2D-@@G6 Mounted Connector: XG4A MIL Connector XG4A MIL Connector A B Two, 4.5 dia. (39.1) 17.6 (Unit: mm) Wiring Diagram (Example for Terminal Block with 50 Poles) Mounted Connector 2 1 4 3 6 5 46 48 50 45 47 49 6 40 Triangular mark 7 DIN Track lock (4.5) 1.2 7 5.8 M3 39 A1 A2 A3 B1 B2 B3 Terminal Block A23 A24 A25 B23 B24 B25 7 Note: There is only one DIN Track lock located in the center of the terminal block for a 20-pole Unit. Note: For all models, the odd-numbered pins on the Connector correspond to row A on the terminal block and the even-numbered pins on the Connector correspond to row B on the terminal block. XW2D-40G6-RF Connector (XG4A-4031) Connector pin No. 2 1 4 3 6 5 8 10 12 7 9 14 16 18 20 22 24 26 28 30 32 34 36 38 40 21 23 25 27 29 31 33 35 37 39 XW2D-40G6-RM Connector (XG4A-4031) Connector pin No. 2 1 4 3 6 5 8 7 10 12 9 14 16 18 20 22 24 17 19 21 23 26 28 30 32 34 36 38 40 25 27 29 31 33 35 37 39 11 13 15 11 13 15 17 19 Triangular mark Triangular mark Terminal No. A1 A2 B1 B2 A3 B3 A4 B4 A5 A6 B5 B6 A7 B7 A8 A9 A10 B8 B9 B10 A11 B11 A12 B12 A13 B13 A14 B14 A15 B15 A16 B16 A17 B17 A18 B18 A19 B19 A20 B20 Terminal No. A1 A2 B1 B2 A3 B3 A4 B4 A5 A6 B5 B6 A7 B7 A8 A9 B8 B9 A10 B10 A11 B11 A12 B12 A13 B13 A14 B14 A15 B15 A16 B16 A17 B17 A18 B18 A19 B19 A20 B20 Terminal Block Note: The dimensions shown here are the same as the XW2D-40G6. Terminal Block Note: The dimensions shown here are the same as the XW2D-40G6. XW2D-@@C6 Mounted Connector: XG4C MIL Connector A B XG4C MIL Connector Two,4.5 dia. (21.1) 17.6 Wiring Diagram (Example for Terminal Block with 50 Poles) Mounted Connector 2 1 4 3 6 5 46 48 50 45 47 49 6 40 Triangular mark 7 DIN Track lock (4.5) 1.2 7 5.8 M3 39 A1 A2 A3 B1 B2 B3 Terminal Block A23 A24 A25 B23 B24 B25 7 Note: There is only one DIN Track lock located in the center of the terminal block for a 20-pole Unit. Note: For all models, the odd-numbered pins on the Connector correspond to row A on the terminal block and the even-numbered pins on the Connector correspond to row B on the terminal block. 2 XW2D XW2D-@@X6 Mounted Connector: MR Socket A B Two, 4.5 dia. (28.2) 17.6 Wiring Diagram (Example for Terminal Block with 50 Poles) Mounted Connector 33 34 35 6 40 48 49 50 32 16 17 18 19 20 1 2 3 7 DIN track lock (4.5) 1.2 39 7 5.8 M3 1 2 7 3 4 5 6 17 19 16 18 20 45 47 49 46 48 50 Terminal Block Note: Connector pin numbers correspond 1-to-1 to terminal block numbers on all models. Note: There is only one DIN Track lock located in the center of the Connector for a 20-pole Unit. XW2D-@@Y6 Mounted Connector: MR Plug A B Two, 4.5 dia. (25.9) 17.6 Wiring Diagram (Example for Terminal Block with 50 Poles) Mounted Connector 1 6 40 2 3 19 20 16 17 18 32 48 49 50 33 34 35 7 DIN Track lock (4.5) 7 1.2 5.8 M3 39 1 2 7 3 4 5 6 17 19 16 18 20 45 47 49 46 48 50 Note: There is only one DIN Track lock located in the center of the terminal block for a 20-pole Unit. Terminal Block Note: Connector pin numbers correspond 1-to-1 to terminal block numbers on all models. 3 XW2D Safety Precautions Precautions for Correct Use Wiring * Always turn OFF the power supply before wiring. Otherwise, cables or other conductors can short the terminals and cause the Unit to fail. * Do not connect or disconnect Connectors with the power turned ON. Otherwise, it may cause malfunctions. Mounting Units to and Removing Units from DIN Track * XW2D Connector-Terminal Block Conversion Units can be mounted side-to-side on DIN Track. * Secure both ends of the XW2D with End Plates. * When removing the Unit from a DIN Track, insert a flat-head screwdriver into the slider and pull the lock out. Wiring Terminal Blocks Using Crimp Terminals (With a Terminal Block with M3 Screws) Round crimp terminals 3.2 mm dia. 5.8 mm max. 3.2 mm 5.8 mm max. Forked crimp terminals Applicable crimp terminals Round crimp terminals Forked crimp terminals 1.25-3 1.25Y-3 Applicable wires AWG 22 to 16 (0.30 to 1.25 mm2) AWG 22 to 16 (0.30 to 1.25 mm2) Handling M3 Screw and Round Terminals Raise the M3 screw with a Phillips screwdriver as shown in diagram (1) and slide the screw toward you to keep the space open. Follow the steps in diagrams (1) and (2) below when using round crimp terminals. Terminal Screw Tightening Torque Use a tightening torque of 0.7 N*m when connecting wires or crimp terminals to the terminal block. A B 4 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2008.11 In the interest of product improvement, specifications are subject to change without notice. Industrial Automation Company http://www.ia.omron.com/ OMRON Corporation (c)Copyright OMRON Corporation 2008 All Right Reserved. |
Price & Availability of XW2D-40C6
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |