|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
2000 A analysis Field measuring instruments CLAMP ON AC/DC HiTESTER 3284 [200A rms, o 33mm(1.30 max.] 3285/-20 [2000A rms, o 55mm ") (2.17") max.] (3285 /3285-20) 3284 3285-20 CAT III 600 V DC to distorted waves http://www.hioki.co.jp/ Analysis for 3285 Analysis applications Supporting a wealth of functions Waveform harmonic and 8807-51 MEMORY HiCORDER Inrush current 0mA Model 3284 and 3285 only 9199 BNC TO BANANA ADAPTER analysis crest value Crest value peak The peak hold function displays the crest value of the inrush current occurring when electrical equipment is started. + 9094 OUTPUT CORD 0 + 0 Using the external output functions of the 3284 or 3285 in combination with a HIOKI MEMORY HiCORDER enables recording of current and frequency fluctuations and recording and harmonic analysis of instantaneous waveforms. The monitor output (MON) spans a wide frequency range from DC to 20 kHz (15 kHz in the case of 3285), which allows the units to be used for electric current analysis in various fields ranging from batteries to inverters. Example of analysis using the MEMORY HiCORDER current waveform (inverter output ) The AC+DC mode enables measurement of the RMS value of full- or half-wave rectified waveforms used in electrical machinery. full-wave rectified waveforms + 0 RMS value of current fluctuations - Harmonic analysis 3284 / 3285 Specifications Function Mode Display Switch*1 Current (A) Voltage (V) Frequency (Hz) Resistance() *8 [ ] in the Specification :3285,3285-20 Accuracy at 23 C 5 C (73 F 9 F), 80% rh or less. Measurement accuracy applies to input of at least 5% of the current range, and at least 10% of the voltage/frequency range. Range 20.00 / 200.0 [200.0 / 2000] Accuracy at DC or 45 to 66 Hz 1.3%rdg.3dgt. 1.3%rdg.3dgt.*2 1.3%rdg.13dgt.*2 1.0%rdg.3dgt. 1.0%rdg.3dgt. 1.0%rdg.7dgt. 0.3%rdg.1dgt. *5 10 to 45Hz or 66 to 2 [ 1 ] kHz PEAK accuracy at DC or 45 to 66 Hz Notes Max. allowable current 200Arms cont. 300A peak max. [2000Arms cont. 2840A peak max.] DC AC DC AC Average / PEAK RMS / PEAK 1.3%rdg.7dgt. 2.0%rdg.5dgt.*3 *4 2.0%rdg.7dgt.*3*4 1.5%rdg.5dgt. 1.5%rdg.7dgt. *5 *6 AC+DC RMS / PEAK RMS / PEAK Resolution is 0.1 [1] A during PEAK Resolution is decreased by 1 digit except in the 600 V range during PEAK 1.3%rdg.7dgt.*6 1.3%rdg.7dgt.*6 1.0%rdg.7dgt. 1.0%rdg.7dgt. 1.0%rdg.7dgt. *7 *7 Average / PEAK 30.00 / 300.0 / 600 Max. allowable voltage 600Vrms cont. 1000V peak max. AC+DC RMS / PEAK 10.00 / 100.0/1000 1000/10.00k 1000 1.0%rdg.1dgt. (at 1000Hz) Effective in the V and A functions Open terminal Voltage 3.1V DC or less 1.5%rdg.5dgt. Threshold level 30 5 or less Continuity Check*8 *1 The peak hold function works automatically during PEAK measurement. *2 Add 1.0% rdg. in the 1800 to 2000 A interval for the 3285. *3 Add 1.0% rdg. in the 1k to 2kHz interval for the 3284. *4 No assured accuracy in the 1800 to 2000 A interval for the 3285. *5 Add 6 dgt. in the 30 V range. *6 Add 4.7% rdg. in the 2300 to 2840 A interval for the 3285. *7 Add 1.0%rdg.13dgt when measuring 700 V to 1000V with Model 3285-20. *8 Model 3285-20 only. Measurable conductor diameter : o33 (1.30") mm, [o55 (2.17") mm] max. Max. usable circuit voltage : 600Vrms (insulated conductor) Functions : recording (MAX. MIN. AVE) ,data hold, auto power-off, auto zero Display update rate : digital indication FAST approx. 4 times/second, NORMAL approx. 2 times/second, SLOW 1 time/ 3 seconds; bar graph indication approx. 4 times/second Display response time : 1 sec or less Range switching : Auto/Manual (Except resistance.) Frequency characteristic : 40 Hz to 2 [1] kHz accuracy External output : A/Hz only: recording output DC1V/f.s. 1.3% rdg.10mV, Response: 250ms (Except model 3285-20) or less (at 090%)/ MON A only : Waveform output 1Vrms/f.s. 1.3% rdg.5mV, 3284 CLAMP ON AC/DC HiTESTER 3285 CLAMP ON AC/DC HiTESTER 3285-20 CLAMP ON AC/DC HiTESTER Frequency band: DC to 20 [15] kHz 3dB Effect of conductor position : within 0.5[0.7] % in any direction from the center of sensor Effect of external magnetic field : 400A/m corresponds to 0.5 [2] A max. Crest factor : 2.5 or less, 1.7 or less in the 600 V range, 3284 is 1.5 or less in the 200A range [1.42 or less in the 2000A range] Safety standard : EN61010-1 CAT III 600V, EN61010-2-032, EN60529 IP40 EMC : EN61326, EN61000-3-2, EN61000-3-3 Ambient temperature of use : 0 to 40C (32F to 104F), 80%rh or less (no condensation) Storage temperature range : -10 to 50C (14F to 122F) or less (no condensation) Power supply : 9445 AC ADAPTER(Except Model 3285-20.) or 6F22 manganese batteryx1 (continuous operation : Model 3284/3285-25 hours, Model 3285-20-20 hours) Dimensions and mass : Approx. 62Wx230[260]Hx39D mm, 460 [540]g (Approx 2.45" Wx 9.06 [10.3]" Hx 1.54" D, 16.3 [19.1] oz.) Options 9445-02 AC ADAPTER (UL) 9445-03 AC ADAPTER (EU) An AC Adapter can only be used with Models 3284 and 3285. * (All include 9207-10 TEST LEADS, 9399 CARRYING CASE(3284), 9345 CARRYING CASE(3285/3285-20), HAND STRAP) 9094 OUTPUT CORD(Jack to banana plug) DISTRIBUTED BY *No CE marking HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@ hioki.co.jp HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: hioki@ hiokiusa.com Shanghai Representative Office : 1704 Shanghai Times Square Office 93 Huaihai Zhong Road Shanghai, 200021, P.R.China TEL +86-21-6391-0090, 0092 FAX +86-21-6391-0360 E-mail: info@hioki.cn All information correct as of Oct. 11, 2005. All specifications are subject to change without notice. 3284E6-5XM-05K Printed in Japan |
Price & Availability of 3284 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |