![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
VER : B_3 update : 98.04.09 AC-DC Power Module APC-E1 SERIES KEY FEATURES Switching Power Module for PCB Mountable Fully Encapsulated Plastic Case Universal Input Range 90-264VAC, 47-440 Hz Regulated Output Low Ripple and Noise Screw Terminal For Optional CE, UL, TUV Approval 2-Years Product Warranty 5 Watts ELECTRICAL SPECIFICATIONS Model No. ( Single Output ) Max Output Wattage (W) Voltage Frequency (Hz) Input Current (Full load) Inrush Current (<2ms) Leakage Current External Fuse (recommend) Voltage (V.DC.) Voltage Accuracy Current (mA) max Line Regulation (LL-HL) (typ.) Load Regulation (5-100%) (typ.) Output Minimum Load Maximum Capacitive Load Ripple Noise Efficiency Hold-up Time Switching Frequency Over Power Protection Protection Over Voltage Protection Short Circuit Protection Input-Output (V.AC) Isolation Input-FG (V.AC) Output-FG (V.AC) Operating Temperature Storage Temperature Environment Temperature Coefficient Humidity MTBF Dimension (L x W x H) Physical Case Material Weight Cooling Method Safety EMC Agency Approvals EMI (Conducted & Radiated Emission) EMS (Noise Immunity) APC-3.3S-E1 5W 47-440 Hz 110 mA max. (115 VAC) / 70 mA max. (230 VAC) 23 A max. (115 VAC) / 46 A max. (230 VAC) 0.75 mA max. 1.5 A slow blow type 3.3V 2% 1500 0.3% 0.5%. 4% 1% 1% 0% 0% 470-23,000F depending on model <0.2% Vout +40mV max (Vp-p) <0.5% Vout +50mV max (Vp-p) 62% 15 ms min. 100 kHz Hiccup technique, auto-recovery Zener diode clamp Hiccup mode, indefinite (automatic recovery) 3000V 1500V 500V -40C...+70C (with derating) -40C...+85C 0.02%/C 95% RH >300,000 h @ 25C (MIL-HDBK-217F) 2.17 x 1.77 x 0.81 Inches 80 g Free air convection UL/cUL, CE, TUV EN 55022 class B EN 50082-1 All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. APC-5S-E1 5W APC-12S-E1 5W APC-15S-E1 5W APC-24S-E1 5W 90-264 VAC or 120-370 VDC 5V 1000 12V 416 15V 333 24V 200 65% 70% 70% 71% ( 55.0 x 45.0 x 20.5 mm ) Tolerance 0.5 mm Plastic resin with Fiberglass (flammability to UL 94V-0) http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -1- VER : B_3 update : 98.04.09 AC-DC Power Module APC-E1 SERIES ELECTRICAL SPECIFICATIONS Model No. ( Dual Output ) APC-5D-E1 5W 90-264 VAC or 120-370 VDC 47-440 Hz 110 mA max. (115 VAC) / 70 mA max. (230 VAC) 23 A max. (115 VAC) / 46 A max. (230 VAC) 0.75 mA max. 1.5 A slow blow type 5V 2% 500 0.3% 0.5%. 0% <0.2% Vout +40mV max (Vp-p) <0.5% Vout +50mV max (Vp-p) 70% 15 ms min. 100 kHz Hiccup technique, auto-recovery Zener diode clamp Hiccup mode, indefinite (automatic recovery) 3000V 1500V 500V -40C...+70C (with derating) -40C...+85C 0.02%/C 95% RH >300,000 h @ 25C (MIL-HDBK-217F) 2.17 x 1.77 x 0.81 Inches 80 g Free air convection UL/cUL, CE, TUV EN 55022 class B EN 50082-1 ( 55.0 x 45.0 x 20.5 mm ) Tolerance 0.5 mm Plastic resin with Fiberglass (flammability to UL 94V-0) 67% 67% 0% 3% 470-23,000F depending on model 200 160 12V 15V APC-12D-E1 5W 5 Watts APC-15D-E1 5W Max Output Wattage (W) Voltage Frequency (Hz) Input Current (Full load) Inrush Current (<2ms) Leakage Current External Fuse (recommend) Voltage (V.DC.) Voltage Accuracy Current (mA) max Line Regulation (LL-HL) (typ.) Load Regulation (5-100%) (typ.) Output Minimum Load Maximum Capacitive Load Ripple Noise Efficiency Hold-up Time Switching Frequency Over Power Protection Protection Over Voltage Protection Short Circuit Protection Input-Output (V.AC) Isolation Input-FG (V.AC) Output-FG (V.AC) Operating Temperature Storage Temperature Environment Temperature Coefficient Humidity MTBF Dimension (L x W x H) Physical Case Material Weight Cooling Method Safety EMC Agency Approvals EMI (Conducted & Radiated Emission) EMS (Noise Immunity) All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -2- VER : B_3 update : 98.04.09 AC-DC Power Module APC-E1 SERIES MECHANICAL DIMENSION ( Top View ) PIN# 1 2 3 4 5 6 SINGLE FG AC IN (N) AC IN (L) -DC OUT NO PIN +DC OUT 5 Watts Dual FG AC IN (N) AC IN (L) -DC OUT COMMON +DC OUT BLOCK DIAGRAM DERATING http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -3- VER : B_3 update : 98.04.09 AC-DC Power Module APC-E1 SERIES SCREW TERMINAL APC-E1-A2 5 Watts PIN# 1 2 3 4. 5 6 7 8 Single FG AC IN (N) AC IN (L) NO CONNECT -DC OUT NO CONNECT +DC OUT NO CONNECT Dual FG AC IN (N) AC IN (L) NO CONNECT -DC OUT COMMON +DC OUT NO CONNECT APC- E1-A4 PIN# 1 2 3 4. 5 6 Single AC IN NO CONNECT -DC OUT NO CONNECT +DC OUT NO CONNECT Dual FG NO CONNECT -DC OUT COMMON +DC OUT NO CONNECT http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -4- VER : B_3 update : 98.04.09 AC-DC Power Module APC-E1 SERIES APC- E1-A5 5 Watts PIN# 1 2 3 4. 5 6 7 8 Single FG AC IN (N) AC IN (L) NO CONNECT -DC OUT NO CONNECT +DC OUT NO CONNECT Dual FG AC IN (N) AC IN (L) NO CONNECT -DC OUT COMMON +DC OUT NO CONNECT APC- E1-A7 PIN# 1 2 3 4. 5 6 Single AC IN NO CONNECT -DC OUT NO CONNECT +DC OUT NO CONNECT Dual FG NO CONNECT -DC OUT COMMON +DC OUT NO CONNECT http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -5- |
Price & Availability of APC-33S-E1
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |