If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
M e d i c a l G r a d e 1 50 Watt Enclosed Switching Power Supplies mmk150s series Universal 88-264VAC Auto Range Input Compact Footprint High Efficiency Regulated Outputs 4000V Isolation Built in EMI Filter 3.5"W x 6"L x 1.75"H model Number MMK150S-5 MMK150S-12 MMK150S-15 MMK150S-24 Output Voltage 5 VDC 12 VDC 15 VDC 24 VDC Output Amps (max) Ripple/Noise pp,typ 30 12.5 10 6 100mv 100mv 100mv 100mv Order On-Line! WWW.AsTRODYNE.COm astrodyne.com 300 myles standish Blvd., Taunton, mA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 M e d i c a l G r a d e 1 50 Watt Enclosed Switching Power Supplies INPUT sPECIFICATIONs Input Voltage Range Frequency Range Inrush Current, typ: 88-132/176-264 VAC Auto Voltage Select 47-63 Hz 20A @ 100VAC * 40A @ 200VAC * mmk150s 0 to +60C (See Derate Curve) -25 to +85C * 10% to 90%, non-cond * EN55011, Class B 100,000 Hrs Mil Std 217, 25C series ENVIRONmENTAL sPECIFICATIONs Oper. Temperature Storage Temperature Relative Humidity EMI (Designed to Meet) MTBF OUTPUT sPECIFICATIONs Voltage and Current Line/Load Regulation (10%-FL) Voltage Tolerance DC Voltage Adjust (typ) Temperature Coefficient Ripple/Noise Over Voltage Protection Short Circuit Protection Hold Up Time Turn On Time Rise Time Over/Under Shoot Leakage Current See Selection Chart 0.5%, typ 1%, typ 6%, typ 0.03%/C 100mV, typ 130%, Latching, Re-power * 160%, Indefinite 20mS, typ (Nom I/P, FL) 1.0 sec, typ 20 msec, typ < 10% of FS 0.3 mA @ 240VAC, 50 Hz PHYsICAL sPECIFICATIONs Size Construction Weight 6" x 3.5" x 1.75" Enclosed 1.37 lb, (630g) GENERAL sPECIFICATIONs Isolation I/P-O/P: 4000VAC I/P-Ground: 1500VAC O/P-Ground: 500 VAC 78%, typ 100Khz, (fixed, typical) UL60601-1, EN60601-1, IEC60601-1 Efficiency Switching Frequency Safety All specifications are typical at nominal input, full load, and 25C unless otherwise noted * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. WWW.AsTRODYNE.COm 300 myles standish Blvd., Taunton, mA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 M e d i c a l G r a d e 1 50 Watt Enclosed Switching Power Supplies mECHANICAL DImENsIONs Pin # 1 2 3 4 5 6 7 mmk150s Outputs ACN ACL GND + Output + Output - Output - Output series PLEASE NOTE: To improve specifications and safety isolation, connection designations may have changed from prior revisions. Please verify connections per product labels on input and output connections prior to applying power to the unit OUTPUT DERATING CURVE (Forced air cooling direction: Straight down from top of unit) 1 2 3 22CFM Forced Air - All Outputs (Recommended) 12/15/24VDC Outputs, Convection Cooled 5VDC Output, Convection Cooled 120 100 80 1 Load, % 60 40 20 0 0 5 10 15 20 25 30 35 40 2 3 45 50 55 60 Ambient Temp, C WWW.AsTRODYNE.COm 300 myles standish Blvd., Taunton, mA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 |
Price & Availability of MMK150S-12 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |