Part Number Hot Search : 
HMC543 TS612 IRGB430U 120SC F2003 B8806 MBJ15 RH1498M
Product Description
Full Text Search
 

To Download RD-50 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 ELECTRONIC COMPONENTS
RSG
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de

Anderungen vorbehalten / subject to change without notice
50W Dual Output Switching Power Supply
Features :
RD-50
series
Universal AC input / Full range Protections:Short circuit/Over load/Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test All using 105 long life electrolytic capacitors Withstand 300VAC surge input for 5 second High operating temperature up to 70 Withstand 5G vibration test High efficiency, long life and high reliability 3 years warranty
SPECIFICATION
MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY(Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE RD-50A CH1 5V 6A 0.3 ~ 6A 54W 120mVp-p 7.0% 1.5% 3.0% 1200ms, 30ms/115VAC at full load 14ms/115VAC at full load 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 80% CH2 12V 2A 0.3 ~ 3A RD-50B CH1 5V 4A 0.3 ~ 6A 53.6W 80mVp-p CH1: 4.75 ~ 5.5V 2.0% 0.5% 0.5% 150mVp-p -4,+8% 1.5% 3.0% CH2 24V 1.4A 0.2 ~ 2A
RIPPLE & NOISE (max.) Note.2 80mVp-p CH1: 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0%
Note.4 Note.5
0.5% 0.5% 500ms, 20ms/230VAC 60ms/230VAC 88 ~ 264VAC 47 ~ 63Hz 79% 1.3A/115VAC 0.8A/230VAC COLD START 33A/230VAC <2mA / 240VAC 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMC
(Note 6)
HARMONIC CURRENT EMS IMMUNITY MTBF
Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A 172.6Khrs min. MIL-HDBK-217F (25 99*97*36mm (L*W*H) 0.41Kg; 45pcs/19.5Kg/0.9CUFT )
OTHERS NOTE
DIMENSION PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
File Name:RD-50-SPEC 2006-04-12
50W Dual Output Switching Power Supply
Mechanical Specification
RD-50
Case No. 905B
series
Unit:mm
1
9.5
51.5
2 3 4 8.2 5 6 7
5.5 97
2-
M
3
20.5
55
3.5
4.5 89 99
6.5
87
7
17.5
3.5
2-M
18
3
74
3.5
Terminal Pin. No Assignment
Pin No. 1 2 3 Assignment AC/L AC/N FG Pin No. Assignment 4,6 DC OUTPUT COM DC OUTPUT +V2 5 DC OUTPUT +V1 7
Derating Curve
Output Derating VS Input Voltage
Ta=25
100
100 90
80 80 60 70
LOAD (%)
LOAD (%)
40
60 50 40
20
-25 -25
0 0
10
20
30
40
50
60
70 (VERTICAL)
88
95
100
115
120
28
140
36
160 180
55.5
200
36
3.5
220 240 264
AMBIENT TEMPERATURE (
)
INPUT VOLTAGE (VAC) 60Hz
File Name:RD-50-SPEC 2006-04-12
ELECTRONIC COMPONENTS
RSG
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de

Anderungen vorbehalten / subject to change without notice


▲Up To Search▲   

 
Price & Availability of RD-50

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X