If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Unit type Ordering information PAA PAA600F R PAA 600 1 2 3 F 4 -5 5 -O 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional C :with Coating G :Low leakage current R :Positive logic control W :with Alarm signal Recommended Noise Filter NAC-16-472 High voltage pulse noise type : NAP series Low leakage current type : NAM series *The Noise Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT PAA600F-3 360 3V 120A PAA600F-5 600 5V 120A PAA600F-12 636 12V 53A PAA600F-15 645 15V 43A PAA600F-24 648 24V 27A PAA600F-48 624 48V 13A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] FREQUENCY[Hz] EFFICIENCY[%] ACIN 100V POWER FACTOR ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT -RC INPUT-FG OUTPUT-RC-FG OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD ACIN 100V ACIN 200V PAA600F-3 PAA600F-5 PAA600F-12 PAA600F-15 PAA600F-24 AC85 - 264 1f or DC120 - 340 5.4typ 8.2typ 2.7typ 4.1typ 50/60 (47 - 63) 70typ 76typ 80typ 81typ 83typ 0.99typ (Io=100%) 0.95typ (Io=100%) 20typ (Io=100%) 40typ (Io=100%) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 12 15 24 120 120 53 43 27 20max 20max 48max 60max 96max 40max 40max 100max 120max 150max 80max 80max 120max 120max 120max 140max 140max 160max 160max 160max 120max 120max 150max 150max 150max 160max 160max 180max 180max 180max 40max 50max 120max 150max 240max 50max 60max 150max 180max 290max 12max 20max 48max 60max 96max 500max (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 2.85 - 3.45 t10% Works over 105% of rating and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating LED (Green) Provided Provided AC3,000V 1minute, Cutoff current = 10mA max,DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA max,DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA max,DC500V 50MW min (At Room Temperature) AC100V 1minute, Cutoff current = 100mA max,DC100V 50MW min (At Room Temperature) -10 to +65C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.234 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B Complies with IEC61000-3-2 190X92X200mm (without terminal block and screw) (WXHXD) /4.0kg max Forced cooling (internal fan) PAA600F-48 INPUT 83typ OUTPUT 48 13 192max 300max 150max 200max 200max 300max 480max 580max 192max PROTECTION CIRCUIT AND OTHERS ISOLATION max ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 According to 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). *2 Drift is change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. * Avoid prolonged use under over-load. A-58 Distribution: RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de Anderungen vorbehalten / subject to change without notice PAA600F External view 4-M4(Top) M4 Name plate Short piece PAA 200 10 6.6 5 + 100-0.5 55 45 28max 19.5 + 150-0.5 + 160-0.5 (Top) 125 118 8.6 10 FG hole M4 Output (-) terminal V.ADJ AC (L) AC (N) FG RG RC CB VB -S -M +M +S 15.5 Output (+) terminal 9 9 Output voltage adjust 12 79.5 M5 LED Terminal cover 15 20 + 100-0.5 75.5 47.5 4-M4 8-M4(Bottom) + 60-0.5 16 (Both sides) 92 + 170-0.5 190 AIR FLOW Weight: 4.0kg or less Tolerance +1 - + 160-0.5 (Bottom) 20 7max Performance data RISE TIME & FALL TIME (PAA600F-5 ) EFFICIENCY (PAA600F-5) 82 80 78 EFFICIENCY 76 DC Output AC Input ACIN 100V Io=100% 74 10 Mounting torque:1.5N . m(16kgf . cm)max 72 Load factor 100% Load factor 50% 70 50ms/DIV 0 100 140 180 220 260 300 INPUT VOLTAGE V HARMOINC CURRENT (PAA600F-5) 10 HARMONIC CURRENT (PAA600F-5) 10 Harmonic current standard class A,D(at odd number) HARMONIC CURRENT HARMONIC CURRENT 1 Load factor 100% Input voltage AC 100V A A Harmonic current standard class A,D(at odd number) 1 Load factor 100% Input voltage AC 230V 0.1 0.1 0.01 0.01 0.001 0 10 20 30 40 0.001 0 10 20 30 40 HARMONIC ORDER HARMONIC ORDER Distribution: RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de A-59 Anderungen vorbehalten / subject to change without notice |
Price & Availability of PAA600F
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |