 FMA Series
Mass flow sensors for gases
FEATURES * Ranges 0...1000 sccm1 and 0...6 slpm2 * Actual mass flow sensing * 1...5 V output * Manifold mount/O-ring sealed * Sensortechnics PRO services
MEDIA COMPATIBILITY
To be used with dry gases only The FMA series is NOT designed for liquid flow and will be damaged by liquid flow through the sensor
SPECIFICATIONS
Maximum ratings Supply voltage3 8 to 15 V typ. 10 0.01 V
ELECTRICAL CONNECTION
P1
P2
Power consumption FMAL001DU FMAL006DU Output load NPN (Sinking) PNP (Sourcing) Temperature limits Operating Storage Mechanical shock
60 mW 75 mW
10 mA 20 mA
123
-25 to 85C -40 to 90C 100 g (5 drops, 6 axes)
Pin 1: Vout Pin 2: +Vs Pin 3: GND
Note: 1 sccm denotes standard cubic centimeters per minute, 1000 sccm = 1 slpm 2 slpm denotes standard liters per minute, which is a flow measurement referenced to standard conditions of 0C, 1 bar, 50% RH. 3 Output voltage is ratiometric to supply voltage
E / 11724 / A
1/5
www.sensortechnics.com
FMA Series
Mass flow sensors for gases
FLOW SENSOR CHARACTERISTICS4
(VS = 10 0.01 V, TA = 25C)
Part no.
FMAL001DU FMAL006DU
Flow range (full scale)
1000 sccm1 6 SLPM2
Max. flow ch an g e5
5.0 l/sec 5.0 l/sec
Output voltage @ trim point
5 0.15 V @ 1000 sccm1 5 0.15 V @ 6 SLPM2
PERFORMANCE CHARACTERISTICS
(VS = 10 0.01 V, TA = 25C)
Characteristics
Zero offset Repeatability and hysteresis (combined) Ratiometricity error3 Temperature effects6 Offset Span -25 to 85 C -25 to 25 C FMAL001DU FMAL006DU 25 to 85 C FMAL001DU FMAL006DU Response time Common mode pressure FMAL001DU FMAL006DU FMAL001DU FMAL006DU
Min.
0.95
Typ.
1.0
Max.
1.05 0.5 1.0 0.3
Unit
V
% reading
0.025 -5.0 -6.0
V
% reading 6.0 6.0 1.0 3.0 150 p si 25 ms
Notes: 1 sccm denotes standard cubic centimeters per minute, 1000 sccm = 1 slpm 2 SLPM denotes standard liters per minute, which is a flow measurement referenced to standard conditions of 0C, 1 bar, 50% RH. 3 Output voltage is ratiometric to supply voltage 4 A 5 micron filter is recommended for all devices. 5 Maximum allowable rate of flow change to prevent damage. 6 Shift is relative to 25 C.
E / 11724 / A
2/5
www.sensortechnics.com
FMA Series
Mass flow sensors for gases
FLOW SPECIFICATIONS
(VS = 10 0.01 V, TA = 25C)
FMAL001DU
Press. (mbar) 2.23 1.87 1.52 1.16 0.94 0.71 0.50 0.33 0.19 0.08 0.00 Flow (sccm)7 1000 900 800 700 600 500 400 300 200 100 0 Nom. (VDC) 5.00 4.97 4.89 4.78 4.63 4.43 4.15 3.76 3.23 2.49 1.00 Tol. ( VDC) 0.15 0.16 0.17 0.18 0.19 0.20 0.21 0.19 0.17 0.14 0.05 Press. (mbar) 20.0 14.7 9.07 6.40 3.35 1.17 0.00
FMAL006DU
Flow (slpm)7 6 5 4 3 2 1 0 Nom. (VDC) 5.00 4.89 4.70 4.40 3.80 3.10 1.00 Tol. ( VDC) 0.15 0.20 0.25 0.35 0.30 0.30 0.05
Note: 7 Devices are calibrated in mass flow. Tolerance values apply to calibration type only.
OUTPUT VS. FLOW CURVES
FMAL001DU
FMAL006DU
E / 11724 / A
3/5
www.sensortechnics.com
FMA Series
Mass flow sensors for gases
OUTLINE DRAWING
30.5 (1.20) 27.7 (1.09)
14.0 (0.55) 32.2 (1.19)
7.62 (0.30)
321
0.64 (0.025) 34.0 (1.34) 3.0 (0.12) 10.9 8.4 (0.43) (0.33) O 3.0 (O 0.12) O 3.51 (O 0.138) 2.54 (0.10) 7.9 (0.31) 12.7 (0.50) 17.3 (0.68)
2.5 (0.10)
4.8 (0.19)
O 6.2 (O 0.24)
P1
123
P2
O 2.0 (O 0.08)
Pin 1: Vout Pin 2: +Vs Pin 3: GND
third angle projection mass: approx. 11 g dimensions in mm (inches)
Note: Positiv flow direction is defined as proceeding from port 1 (P1) to port 2 (P2) and results in positive output.
E / 11724 / A
4/5
www.sensortechnics.com
FMA Series
Mass flow sensors for gases
GAS CORRECTION FACTORS8
Gas type Helium (He) Hydrogen (H2) Argon (Ar) Nitrogen (N2) Oxygen (O2) Ai r Nitric oxide (NO) Carbon monoxide (CO) Methane (CH4) Ammonia (NH3) Nitrous oxide (N2O) Nitrogen dioxide (NO2) Carbon dioxide (CO2) Correction factor (approx.) 0.59 0.79,10 0.95 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.35 1.35 1.35
Notes: 8 Gas correction factors are referenced to nitrogen (N2) as calibration gas type. Approximate gas correction factors are provided as guidelines only. Individual gas types may perform differently at temperature extremes and varying flow rates. 9 When sensing Hydrogen (H2) or Helium (He) it may be necessary to power the mass flow sensor using increased supply voltage: Hydrogen typ. 12 V, Helium typ. 15 V 10 Hydrogen (H2) flow measurement requires the use of a special sensor. These devices provide normal operation when sensing hydrogen flow and are designated with an "H" at the end of the order number.
ORDERING INFORMATION - AVAILABLE LISTINGS
Note: Preferred listings are highlighted in grey
Flow range
1 0 0 0 sccm 6 S LP M
Dry gas
FMAL001DU FMAL006DU
Hydrogen gas10
FMAL001HU ---
Sensortechnics PRO services: * Extended guarantee period of 2 years * Improved performance characteristics * Custom product modifications and adaptations even for small quantities * Advanced logistics models for supply inventory and short delivery times * Technical support through application engineers on the phone or at your site * Fastest possible technical response for design and QA engineers ... plus other services on request
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. E / 11724 / A 5/5
www.sensortechnics.com


▲Up To Search▲   

 
Price & Availability of FMAL001DU

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X