![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Embedded Power for Business-Critical Continuity LPS40-M Series 40 Watts Medical Total Power: Input Voltage: # of Outputs: 40-55Watts 85-264VAC 120-300VDC Single Rev. 9.8.09_28 LPS40-M Series of 3 Electrical Specifications Special Features * * * * * * * * * * * Input Inputrange: Frequency: Inrushcurrent: Inputcurrent: Efficiency: EMIfilter: Safetyground leakagecurrent: 85-264VAC;120-300VDC 47-440Hz <18Apeak@115VAC;<36Apeak@230VAC,coldstart@25C 1Amax.(RMS)@115VAC 70% typical at full load FCCClassBconducted;CISPR22ClassAconducted; EN55022ClassAconducted;VDE0878PT3ClassAconducted <75A@50/60Hz,264VACinput Medicalsafetyapprovals Universalinput 3"x5"footprint Lessthan1Uhigh Remotesenseonmainoutput Lowoutputripple Adjustable5Voutput Overvoltageprotection Overloadprotection 110KHzswitchingfrequency LPX40enclosurekitavailable Output Maximumpower: Adjustmentrange: Hold-uptime: Overloadprotection: 40Wforconvection;55Wwith30CFMforcedair -5,+10%minimum 20ms@40Wload,115VACnominalline Safety * VDE 0750/EN60601-1 (IEC601) * UL UL2601E182560 * CSA CSA22.2No.601.1 LR109492 * CE Mark(LVD) Shortcircuitprotectiononalloutputs Caseoverloadprotected@110 -145%abovepeakrating Overvoltageprotection: 5Voutput;5.7to6.7VDC.Otheroutputs10%to25%abovenominal output Remotesense: Compensatesfor0.5Vleaddropminimum. Willoperatewithoutremotesenseconnected. Reverseconnectionprotected. Embedded Power for Business-Critical Continuity EnvironmentalSpecifications Operatingtemperature: 0to50Cambient.Derateeachoutput2.5%perdegreefrom50to70C,-20Cstartup Storagetemperature: -40Cto+85C Temperaturecoefficient: 0.4%perC Electromagnetic DesignedtomeetIEC801,-2,-3,-4,-5,-6,Level3 susceptibility: Humidity: Vibration: MTBFdemonstrated: Operating;non-condensing5%to95%RH Threeorthogonalaxes,sweepat1oct/min,5min.dwellatfourmajorresonances0.75G peak5Hzto500Hz,operational >550,000hoursatfullloadand25Cambientconditions Rev. 9.8.09_28 LPS40-M Series 2 of 3 OrderingInformation Model Number LPS42-M LPS43-M Output Voltage 5V 12V Minimum Load 0A 0A Maximum Load with Convection cooling 8A 3.3A Maximum Load with 30CFM Forced Air 11A 4.5A Peak Load1 12A 5A Regulation2 2% 2% Ripple P/P (PARD)3 50mV 120mV 150mV 240mV LPS44-M 15V 0A 2.6A 3.6A 4A 2% LPS45-M 24V 0A 1.6A 2.3A 2.5A 2% 1.Peakcurrentlasting<30secondswithamaximum10%dutycycle. 2.At25Cincludinginitialtolerance,linevoltage,loadcurrentsandoutputvoltagesadjustedtofactorysettings. 3.Peak-to-peakwith20MHzbandwidthand10Finparallelwitha0.1Fcapacitoratratedlinevoltageandloadranges. Power Derating Curve 55W 30 CFM Forced Air Cooling 40W 30W Output Power (Watts) 20W Natural Convection Cooling 27.5W 20W 10W 0W 0C 10C 20C 30C 40C 50C 60C 70C TA - Ambient Temperature - C Embedded Power for Business-Critical Continuity MechanicalDrawing 5.00" (127) Americas 5810VanAllenWay Carlsbad,CA92008 USA Telephone:+17609304600 Facsimile: +17609300698 SK201 Rev. 9.8.09_28 LPS40-M Series 3 of 3 0.22" (5.6) M1 GND 4.55" (115.6) M2 _ + SK 2 3.00" (76.2) 2.55" (64.8) 3 1 Remote Sense Connector Voltage Adj. Pot Europe (UK) SK 1 N L 1 2 3 4 5 6 WaterfrontBusinessPark MerryHill,Dudley WestMidlands,DY51LX UnitedKingdom Telephone:+44(0)1384842211 Facsimile: +44(0)1384843355 Asia (HK) 0.15" (4) DIA (4 places) 14/F,LuPlaza 2WingYipStreet KwunTong,Kowloon HongKong Telephone:+85221763333 Facsimile: +85221763888 Forglobalcontact,visit: www.PowerConversion.com techsupport.embeddedpower @emerson.com 1.14" (29) 0.197" (5) Whileeveryprecautionhasbeentakentoensure accuracyandcompletenessinthisliterature,Emerson NetworkPowerassumesnoresponsibility,anddisclaims allliabilityfordamagesresultingfromuseofthis informationorforanyerrorsoromissions. Emerson Network Power. Thegloballeaderinenabling business-criticalcontinuity. PinAssignments Connector LPS42-M LPS43-M LPS44-M LPS45-M SK1-1 SK1-3 SK2-1 SK2-2 SK2-3 SK2-4 SK2-5 SK2-6 SK201-1 SK201-2 Neutral Line +5V +5V +5V Common Common Common +Sense -Sense Neutral Neutral Line Line +12V +15V +12V +15V +12V +15V Common Common Common Common Common Common +Sense +Sense -Sense -Sense Neutral Line +24V +24V +24V Common Common Common +Sense -Sense MatingConnectors Molex09-50-8031(USA) 09-91-0300(UK) PINS:08-52-0113 DCOutputs: Molex09-50-8061(USA) 09-91-0600(UK) PINS:08-52-0113 RemoteSense: Molex22-01-2025 PINS:08-52-0123 EmersonNetworkPowerConnectorKit#70-841-006,includesallof theabove 1. Specificationssubjecttochangewithoutnotice. 2 . Alldimensionsininches(mm),toleranceis0.02"(0.5mm) 3. MountingholesM1andM2shouldbegroundedforEMI purposes. 4. MountingholeM1issafetygroundconnection. 5. Specificationsareforconvectionratingatfactorysettingsat 115VACinput,25Cunlessotherwisestated. 6. Warranty:2year 7. Weight:0.5lbs/0.23kg ACInput: ACPower Connectivity DCPower EmbeddedComputing Embedded Power Monitoring OutsidePlant PowerSwitching&Controls PrecisionCooling Racks&IntegratedCabinets Services SurgeProtection EmersonNetworkPower.com EmersonNetworkPowerandtheEmerson NetworkPowerlogoaretrademarksand servicemarksofEmersonElectricCo. (c)2009EmersonElectricCo. |
Price & Availability of LPS40-M09
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |