If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
BIG SOZA CELL BSOZA501 THRU BSOZA506 TECHNICAL SPECIFICATION FEATURES * * * * VOLTAGE RANGE CURRENT 100 to 600 Volts 50.0 Amperes Low Leakage Low forward voltage drop High current capability High forward surge current capacity .299(7.6) .283(7.2) DIA MECHANICAL DATA * * * * * * Copper slug Cell with 180milSQU Technology: cell with vacuum soldered Polarity: blue dots denotes cathode end Mounting Position: Any Weight: 0.0219 ounces, 0.62 grams 0.086(2.20) 0.078(2.0) Dimensions in inches and (millimeters) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS * * * Ratings at 25 ambient temperature unless otherwise specified Single Phase, half wave, 60HZ, resistive or inductive load For capacitive load derate current by 20% SYMBOLS BSOZA501 100 70 100 BSOZA502 200 140 200 BSOZA503 300 210 300 50.0 BSOZA504 400 280 400 BSOZA506 600 420 600 UNIT Volts Volts Volts Amps Maximum Repetitive Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current, At Tc=110 Peak Forward Surge Current 3.3mS single half sine wave superimposed on Rated load (JEDEC method) Maximum instantaneous Forward Voltage at 100A Maximum DC Reverse Current at Rated TA=25 DC Blocking Voltage per element Typical Thermal Resistance Operating and Storage Temperature Range TA=100 VRRM VRMS VDC IO IFSM VF IR RJC TJ,TSTG 500 1.08 5.0 250 0.8 (-65 to +175) Amps Volts UA /W Notes: 1. Enough heatsink must be considered in application. E-mail: sales@cnmic.com Web Site: www.cnmic.com BIG SOZA CELL BSOZA501 THRU BSOZA506 VOLTAGE RANGE CURRENT 100 to 600 Volts 50.0 Amperes RATINGS AND CHARACTERISTIC CURVES BSOZA501 THRU BSOZA506 F1G.1 TYPICAL FORWARD CURRENT DERATING GURVE AVERAGE FORWARD CURRENT, (A) F1G.2 MAXIMUM NON-REPETITIVE PEAK FORWARD SURGE CURRENT PEAK FORWARD SURGE CURRENT,(A) 60 50 40 30 20 10 0 0 25 50 75 Single Phase Half Wave 60Hz Resistive or Inductive Load 0.375(9.5mm) Lead Length 600 8.3ms Single Half Sine-Wave 500 400 300 200 100 1 Cycle 1 2 4 6 8 10 20 40 60 80 100 (JEDEC Method) Tj=Tj max 110 100 125 150 175 NUMBER OF CYCLES AT 60 Hz CASE TEMPERATURE, () F1G.3 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS 1000 F1G.4 FORWARD ROWER DISSIPATION AVERAGE POWER DISSIPATION (W) 60 INSTANTANEOUS FORWARD CURRENT, (A) 100 40 SQUARE WAVE DC 20 10 T1=25 PULSE WIDTH=300S 1%DUTY CYCLE 1.0 0 0 20 30 40 50 60 AVERAGE FORWARD CURRENT, (A) 0.1 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 INSTANTANEOUS FORWARD VOLTAGE,(V) E-mail: sales@cnmic.com Web Site: www.cnmic.com |
Price & Availability of BSOZA501 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |