|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
General Purpose Relays SCHRACK Safety Relay SR6 D/M n n n n 4 pole safety relay with either 2 NO+2 NC or 3 NO+1 NC contacts Forcibly guided contacts according to EN 50205 Rated current 8 A High insulation distances for safe separation of electrical circuits Applications Emergency shut-off, press control, machine control, elevator and escalator control, safety modules F0206-ED Approvals V REG.-Nr.of128935, Z request T 968/EL 350.04/09 E214024, Technical data approved types on Contact data 3 NO contacts and 1 NC contact or 2 NO contacts and 2 NC contacts Contact set single contact, forcibly guided type A according to EN 50205 Type of interruption micro disconnection Rated voltage / max. switching voltage AC 250 / 400 VAC Rated current 8A Maximum breaking capacity AC 2000 VA Contact material AgSnO2 Minimum contact load 10 mA / 5 V Contact resistance w 100 mOhm / 1 A / 24 VDC w 20 Ohm / 10 mA / 5 VDC Rated frequency of operation with / without load 6 min-1 / 150 min-1 Contact ratings Type Contact Load*) EN60947-5-1 SR6 1 NO SR6 1 NO *) load on one pole Contact configuration Ambient temp. [C] 23C 23C Cycles 6,050 6,050 IEC 947-5-1 (AC15) utilization category 250 VAC / 5 A IEC 947-5-1 (DC13) utilization category 24 VDC / 6 A Coil data Rated coil voltage range DC coil Operative range to IEC 61810 5...110 VDC 2 Coil versions, DC-coil Coil Rated Operate Release / Reset Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ohm mW 005 5 3.8 0.5 21+10% 1190 006 6 4.5 0.6 30+10% 1200 009 9 6.8 0.9 68+10% 1191 012 12 9.0 1.2 120+10% 1200 018 18 13.5 1.8 270+10% 1200 021 21 15.8 2.1 368+10% 1198 024 24 18.0 2.4 480+10% 1200 036 36 27.0 3.6 1080+10% 1200 040 40 30.0 4.0 1333+10% 1200 048 48 36.0 4.8 1920+10% 1200 060 60 45.0 6.0 3000+12% 1200 110 110 82.5 11.0 10080+12% 1200 All figures are given for coil without preenergization, at ambient temperature +23C Other coil voltages on request 1 Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' section in the catalogue or at schrackrelays.com in the `Schrack' section. Specifications subject to change. General Purpose Relays SCHRACK Safety Relay SR6 D/M (Continued) Insulation Dielectric strength coil-contact circuit 3000 Vrms open contact circuit 1500 Vrms adjacent contact circuits 3000 / 4000 Vrms (in longitudinal direction) Clearance / creepage coil-contact circuit W 5.5 / 5.5 mm adjacent contact circuits W 5.5 / 5.5 mm W 15 / 15 mm (in longitudinal direction) Material group of insulation parts IIIa Tracking index of relay base PTI 250 Insulation to IEC 61810-1 Type of insulation coil-contact circuit basic open contact circuit micro disconnection adjacent contact circuits reinforced (in longitudinal dir) Rated insulation voltage 250 V Pollution degree 2 Rated voltage system 230 / 400 V Overvoltage category III Insulation to EN 50178 Type of insulation coil-contact circuit reinforced adjacent contact circuits reinforced PCB layout / terminal assignment Bottom view on solder pins 2 NO+2 NC versions S0368-CI S0368-CJ Other data Mechanical endurance 10x106 cycles Material RoHS - Directive 2002/95/EC compliant as per product date code 0407 Environment Ambient temperature range -25...+70C Vibration resistance (function) NO / NC contact > 8 / 2.5 g, 10....200 Hz Shock resistance (function) NO / NC contact > 10 / 2.5 g, 16 ms half sine Category of protection RT III1) Processing Resistance to soldering heat 260C / 5 s Relay weight 30 g Packaging unit 10 pcs 1) 3 NO + 1 NC version S0368-CK please contact technical support for washing parameters Accessories PCB socket and hold down clip contact technical support S0368-CL Dimensions S0367-DB 2 Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' section in the catalogue or at schrackrelays.com in the `Schrack' section. Specifications subject to change. General Purpose Relays SCHRACK Safety Relay SR6 D/M (Continued) Product key Type SR6 Safety Relay SR6 D/M Contact configuration D 2 NO + 2 NC contacts (2 form A + 2 form B) M 3 NO + 1 NC contacts (3 form A + 1 form B) Contact material 4 AgSnO2 Coil Coil code = rated coil voltage (e.g. 024=24 VDC) Other types on request Typical product key SR6 D 4 012 Product key SR6D4012 SR6D4018 SR6D4021 SR6D4024 SR6D4040 SR6D4110 SR6M4006 SR6M4012 SR6M4018 SR6M4021 SR6M4024 SR6M4110 Type 4-pole safety relay Contact configuration 2 NO + 2 NC contacts Contact material AgSnO2 3 NO + 1 NC contacts Coil 12 VDC 18 VDC 21 VDC 24 VDC 40 VDC 110 VDC 6 VDC 12 VDC 18 VDC 21 VDC 24 VDC 110 VDC Part number 1415078-1 7-1415354-1 8-1415353-1 6-1415027-1 9-1415366-1 1415062-1 6-1415053-1 7-1415353-1 1415354-1 6-1415353-1 3-1415353-1 1-1415354-1 3 Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' section in the catalogue or at schrackrelays.com in the `Schrack' section. Specifications subject to change. |
Price & Availability of SR6M4021 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |