If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Specification AXLE208 Oscillator type : TCXO in CO15 package Parameter Frequency range Frequency stability vs. temperature vs. supply voltage variation vs. load change long term (aging) per year Frequency adjustment range Mechanical (internal trimmer) Electronic Frequency Control (EFC) EFC voltage VC EFC slope (f / VC) EFC input impedance RF output Signal waveform Issue: 01 Date:2008-05-07 min. 6 1 typ. max. 190 800 Unit MHz MHz ppm ppm ppm ppm ppm ppm ppm V V k Condition (Clipped) Sinewave HCMOS See tables 1 & 2 10 % @+40C Option 1 = blank Option 1 = "V" Option 2 = "3" Option 2 = "5" 0.5 ppm to 5 ppm 0.1 0.3 0.2 1 3 5 0.15 0.5 100 1.65 2.5 positive 3.15 4.5 Load Amplitude Supply voltage VS Current consumption (Note 3) Storage temperature range Enclosure (see drawing) Marking Packing Construction Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated 2. All combinations of options might not be available. Please consult factory 3. Depending on frequency and supply voltage Sine wave Clipped Sine wave HCMOS 50 10 k || 10 pF 15 pF 0 dBm +10 dBm 0.8 V p-p 1.0 V p-p According to relevant Logic Standard 3.15 3.3 3.45 V 4.75 5.0 5.25 V 12 ~ 30 mA 2 ~ 30 mA 15 ~ 50 mA -45 +90 C 20.3 x 20.3 x 5.3 max. mm AXLE208 Freq wwAXPyy Palette Lead(Pb) -free Option 3 = "S" Option 3 = "C" Option 3 = "H" Option 3 = "S" Option 3 = "C" Option 3 = "H" Option 3 = "S" / 3.3 V Option 3 = "S" / 5.0 V Option 3 = "C" / 3.3 V Option 3 = "C" / 5.0 V Option 3 = "H" Option 2 = "3" Option 2 = "5" Option 3 = "S" Option 3 = "C" Option 3 = "H" IEC 60679-3 CO-15 Specification Frequency ww=week, yy=year GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXLE208 page 1(2) ww.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com Frequency Stability over Temperature Table 1 Code4 Stability 05 0.5 10 1.0 15 1.5 20 2.0 25 2.5 30 3.0 35 3.5 50 5.0 Table 2 Lower Temperature Code5 Temp/C 0 0 1 -10 2 -20 3 -30 4 -40 Upper Temperature Code5 A B C D E F Temp/C +50 +60 +70 +75 +80 +85 Ordering Code: Part number AXLE208 Option 1 EFC Option 2 Supply Voltage Option 3 Output Option 4 Stability Option 5 Temp. range _ or "V" 5 or 3 S, C, H See tables 1 & 2 Example: AXLE208V-5-S-10-3D Enclosure drawing Pin connections Pin # Symbol Function 1 N.C. or VC No Connection or Control Voltage (EFC) 2 RF OUT RF Output 3 Vs Supply Voltage 4 GND Ground 5 GND Ground GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXLE208 page 2(2) ww.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com |
Price & Availability of AXLE208
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |