![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
1310 Series DC Voltage Level Sensor, Relay Output Product Facts I I I Standard models combine DC voltage-sensing circuit with 2A DPDT output relay. Various applications I Battery protection I Computer protection I Low or high voltage alarms Many customizing options I Solid state output I Two-stage sensing (voltage band) I Up to 10A relay output I Controlled dropout differential I Operate with auxiliary control voltage I Time delay on trip point I Tighter accuracy I Different package, mounting, header The CII 1310 series DC voltage sensor is essentially a voltage monitoring device operating a snap-action transistor circuit with low drift and inherent temperature compensation. This device will either open or close a circuit when a predetermined voltage is present at the input. By using a CII electromechanical relay as the output of the voltage sensor, a positive switching action can be achieved with very close differential between pull-in and drop-out voltages. The unit is potted and hermetically sealed and is designed to meet the environmental requirements of MIL-R-83726. Outline Dimensions .063 MAX. .375 [1.60] [9.53] #4-40 THD 4 PLACES .625 [15.875] Electrical Specifications Pull-In Voltage: Any voltage level between 10 to 150Vdc. Drop-Out Voltage: 0 to 0.5V below pull-in voltage. Current Drain: 15mA max @ 25C. Accuracy: 2.5% of set point over temperature range. Max. Allowable Applied Voltage: 150% of specified pull-in voltage. Auxiliary Voltage: None required. Operate and Release Times: 50ms max. over the temperature range. Contact Arrangement: 2 Form C (DPDT). Contact Rating: 2 amps resistive @ 30Vdc 300mA resistive @ 115 Vrms, 400 Hz. 2.0 MAX. [50.8] 2.0 MAX. [50.8] 2.0 MAX. [50.8] 1.25 [31.75] .625 [15.875] .063 MAX. [1.60] .375 [9.53] INDEX DOT 1.00 MAX. [25.4] .625 [15.875] .875 1.25 MAX. [22.22] [31.75] .75 DIA. [19.05] MAX. #4-40 THD 4 PLACES 1.00 MAX. [25.4] .625 [15.875] .875 1.25 MAX. [22.22] [31.75] .250 [6.35] INDEX DOT .250 [6.35] .375 [9.53] .063 MAX. [1.60] 1.00 MAX. [25.4] 1.25 MAX. [31.75] #4-40 THD 4 PLACES INDEX DOT Mounting Option A Mounting Option B Mounting Option C Environmental Specifications Temperature Range: -55C to +125C. Vibration: 20 G's, 10 - 2,000 Hz. Shock: 50 G's, 11 1ms duration. Insulation Resistance: 1,000 megohms, min., at 500Vdc, all terminals to case. Dielectric Strength: 1,000Vrms, 60 Hz., at sea level, all terminals to case. Sealing: Hermetic, 1.3 in. (33.0mm) of mercury. Life: 100,000 operations, min. Weight: 3.5 oz (99.2g) max. Wiring Diagram - INPUT + INDEX DOT Part Numbering System Typical Part Number 1310 -2 Series: 1310 = DC Voltage Level Sensor, Relay Output Contact Form: 2 = 2 Form C (DPDT) Mounting (see outline dimension drawings): A = Studs on bottom B = Studs on top C = Studs on side Pull-In Voltage: Specify any level between 10 and 150Vdc A - 24.5 (c) 2006 by Tyco Electronics Corporation. All Rights Reserved. CII and TYCO are trademarks. Other products and company names mentioned herein may be trademarks of their respective owners. 1 Catalog 7-1773439-4 Revised 1-06 www.tycoelectronics.com Dimensions are in inches and millimeters unless otherwise specified. Values in brackets are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA: 1-800-522-6752 Canada: 1-905-470-4425 Mexico: 01-800-733-8926 C. America: 52-55-5-729-0425 South America: 55-11-3611-1514 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-141-810-8967 |
Price & Availability of 1310-2A-245
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |