Filename: tfs 380n.doc Version 1.1 10.10.2005 VI TELEFILTER Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 C dBm Filter specification TFS 380N 1/5 499 || -6,3 pF 480 || -6,2 pF Characteristics Remark: The nominal frequency fN is fixed at 380 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative attenuation arel of the TFS 380N is the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 30 dB filter attenuation level relative to the insertion loss ae. All specified data are met within the operating temperature range. Data Insertion loss at fN (reference level) Nominal frequency Centre frequency at ambient temperature Passband Pass band ripple Relative attenuation fC fC fC 3,0 7,5 MHz ... fC MHz ... fC MHz ... fC MHz OTR TCf ** 3,0 3,75 50,0 arel MHz MHz MHz PB ae fN fC typ. value 8,5 380,0 0,8 dB MHz fN dB tolerance / limit max. 11 380,0 0,4 2,0 1,5 dB MHz MHz MHz dB max. 0,5 1 34 46 -18 dB dB dB ns max. max. min. max. 1 3 30 75 dB dB dB ns Group delay ripple in fN 2,5 Operating temperature range Storage temperature range - 40 C ... +85 C - 40 C ... + 85 C ppm/K Temperature coefficient of frequency *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz) Generated: Checked / Approved: Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 380n.doc Version 1.1 10.10.2005 VI TELEFILTER Filter characteristic 0 Filter specification TFS 380N 2/5 0 0.91 -5 -1 0.85 -10 -2 0.79 -15 -3 0.73 magnitude in dB magnitude in dB -20 -4 0.67 delay in s -25 -5 0.61 -30 -6 0.55 -35 -7 0.49 -40 -8 0.43 -45 -9 0.37 -50 330 340 350 360 370 380 390 frequency in MHz 400 410 420 430 -10 375 376 377 378 379 380 381 frequency in MHz 382 383 384 0.31 385 Construction and pin connection (All dimensions in mm) S 380N T42 1 3 2 Max. Date code 7,2 Max. 2,54 0,2 1 2,54 0,2 5,2 Max. 1 2 3 4 5 6 7 8 9 10 11 12 Ground Ground Output RF Return Output Ground Ground Ground Ground Input RF Return Input Ground Ground 0,80 50 Test circuit 1 Date code: T U V ... Year + week 2005 2006 2007 L1 10 9 L2 4 L3 SAW 3 L4 1, 2, 5, 6, 7, 8, 11, 12 Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 380n.doc Version 1.1 10.10.2005 VI TELEFILTER Stability characteristics Filter specification TFS 380N 3/5 After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow): 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 16,00 0,3 Po : 4,00 0,1 Do : 1,50 +0,1/-0 E : 1,75 0,1 F : 7,50 0,1 G(min) : 0,60 P2 : 2,00 0,1 P1 : 8,00 0,1 D1(min) : 1,50 Ao : 5,50 0,1 Bo : 7,50 0,1 Ct : 13,5 0,1 Date Code P1 Po P2 t Do G Ct Bo F Ko Typ PIN Marker D1 Ao W2 A C N W1 E G W Reel (all dimensions in mm) A : 330 W1 : 16,4 +2/-0 W2(max) : 22,4 N(min) : 50 C : 13,0 +0,5/-0,2 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 380n.doc Version 1.1 10.10.2005 VI TELEFILTER Air reflow temperature conditions Filter specification TFS 380N 4/5 Conditions Average ramp-up rate (30C to 217C) > 100C > 150C > 217C Peak temperature Time within 5C of actual peak temperature Cool-down rate (Peak to 50C) Time from 30C to Peak temperature Exposure less than 3C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260C between 10 and 30 seconds less than 6C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / C max. 260C 217C max. 300 s 10 ... 30 s 30 ... 150 s Time / s Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 380n.doc Version 1.1 10.10.2005 VI TELEFILTER History Version 1.0 1.1 Reason of Changes Filter specification TFS 380N 5/5 Name Strehl Pfeiffer Date 22.09.2005 10.10.2005 Generation of development specification terminating impedance, typical values and filter characteristic added Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS380N
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |