 Filename: tfs 380n.doc
Version 1.1
10.10.2005
VI TELEFILTER
Measurement condition
Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 C dBm
Filter specification
TFS 380N
1/5
499 || -6,3 pF 480 || -6,2 pF
Characteristics
Remark:
The nominal frequency fN is fixed at 380 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative attenuation arel of the TFS 380N is the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 30 dB filter attenuation level relative to the insertion loss ae. All specified data are met within the operating temperature range.
Data
Insertion loss at fN (reference level) Nominal frequency Centre frequency at ambient temperature Passband Pass band ripple Relative attenuation fC fC fC 3,0 7,5 MHz ... fC MHz ... fC MHz ... fC MHz OTR TCf ** 3,0 3,75 50,0 arel MHz MHz MHz PB ae fN fC
typ. value
8,5 380,0 0,8 dB MHz fN dB
tolerance / limit
max. 11 380,0 0,4 2,0 1,5 dB MHz MHz MHz dB
max.
0,5 1 34 46 -18
dB dB dB ns
max. max. min. max.
1 3 30 75
dB dB dB ns
Group delay ripple in fN 2,5 Operating temperature range Storage temperature range
- 40 C ... +85 C - 40 C ... + 85 C ppm/K
Temperature coefficient of frequency
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz)
Generated:
Checked / Approved:
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 380n.doc
Version 1.1
10.10.2005
VI TELEFILTER
Filter characteristic
0
Filter specification
TFS 380N
2/5
0
0.91
-5
-1
0.85
-10
-2
0.79
-15
-3
0.73
magnitude in dB
magnitude in dB
-20
-4
0.67 delay in s
-25
-5
0.61
-30
-6
0.55
-35
-7
0.49
-40
-8
0.43
-45
-9
0.37
-50 330
340
350
360
370
380 390 frequency in MHz
400
410
420
430
-10 375
376
377
378
379 380 381 frequency in MHz
382
383
384
0.31 385
Construction and pin connection
(All dimensions in mm)
S 380N T42
1 3
2 Max.
Date code
7,2 Max. 2,54 0,2 1
2,54 0,2 5,2 Max.
1 2 3 4 5 6 7 8 9 10 11 12
Ground Ground Output RF Return Output Ground Ground Ground Ground Input RF Return Input Ground Ground
0,80
50 Test circuit
1
Date code: T U V ...
Year + week 2005 2006 2007
L1
10 9
L2
4
L3
SAW
3
L4
1, 2, 5, 6, 7, 8, 11, 12
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 380n.doc
Version 1.1
10.10.2005
VI TELEFILTER
Stability characteristics
Filter specification
TFS 380N
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow): 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel: IEC 286 - 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm
Pull Off Direction
Tape (all dimensions in mm) W : 16,00 0,3 Po : 4,00 0,1 Do : 1,50 +0,1/-0 E : 1,75 0,1 F : 7,50 0,1 G(min) : 0,60 P2 : 2,00 0,1 P1 : 8,00 0,1 D1(min) : 1,50 Ao : 5,50 0,1 Bo : 7,50 0,1 Ct : 13,5 0,1
Date Code P1 Po P2
t
Do
G Ct Bo F
Ko Typ PIN Marker D1 Ao
W2 A C N W1
E G W
Reel (all dimensions in mm) A : 330 W1 : 16,4 +2/-0 W2(max) : 22,4 N(min) : 50 C : 13,0 +0,5/-0,2
The minimum bending radius is 45 mm.
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 380n.doc
Version 1.1
10.10.2005
VI TELEFILTER
Air reflow temperature conditions
Filter specification
TFS 380N
4/5
Conditions Average ramp-up rate (30C to 217C) > 100C > 150C > 217C Peak temperature Time within 5C of actual peak temperature Cool-down rate (Peak to 50C) Time from 30C to Peak temperature
Exposure less than 3C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260C between 10 and 30 seconds less than 6C/second no greater than 300 seconds
Chip-mount air reflow profile Temperature / C
max. 260C
217C
max. 300 s
10 ... 30 s 30 ... 150 s
Time / s
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 380n.doc
Version 1.1
10.10.2005
VI TELEFILTER
History
Version 1.0 1.1 Reason of Changes
Filter specification
TFS 380N
5/5
Name Strehl Pfeiffer
Date 22.09.2005 10.10.2005
Generation of development specification terminating impedance, typical values and filter characteristic added
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS380N

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X