![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
PD - 94551 ATR28XXT SERIES ADVANCED ANALOG HYBRID-HIGH RELIABILITY DC/DC CONVERTERS Description The ATR28XXT Series of DC/DC converters provide 30 watts of output power over the full military temperature range with no derating. These devices are pin compatible with the Advanced Analog ATO series converters but offer twice the maximum output power in a lower profile package. A custom CMOS ASIC pulse width modulator operating at a nominal switching frequency of 550KHz combined with a unique magnetic feedback reduces circuit complexity for enhanced reliability. These converters provide 500 volt input to output isolation and operate in highly efficient single forward mode. The advanced feedback design and high operating frequency provide an extremely wide bandwidth control loop with high gain and phase margin. This results in fast dynamic line and load response as well as superior audio rejection. The control loop is compensated to provide optimum performance over the full military temperature range and over the 16 to 40 volt input voltage range. These converters are protected against both continuous output short circuits and output overload. Either load fault condition will result in operating in a low power dissipation foldback mode. The converters will shut down for approximately 15 milliseconds, then attempt to restart. This cycle will continue indefinitely unless the load fault is corrected. Recovery to normal operation is automatic upon removal of the load fault. Manufactured in a facility full qualified to MIL-PRF38534, these converters are available in four screening grades to satisfy a wide range of requirements. The CH grade is fully compliant to the requirements of MILPRF-38534 for class H. The HB grade is processed and screened to the class H requirement, but element evaluation and Periodic Inspections (PI) are not required. Both grades are tested to meet the complete group "A" test specification over the full military temperature range without output power deration. 28V Input, Triple Output ATR Features n n n n n n n n n n 30 Watt Output Power Flexible Output Loading -55C to +125C Operation Pin Compatible with ATO 0.410" Maximum Height 16 to 40 VDC Input Range 500 Volt Input to Output Isolation High Audio Rejection MIL-STD-704 Compatible Load Fault Protection - Short Circuit and Overload n TTL level Compatible Synchronization Two grades with more limited screening are also available for use in less demanding applications. Variations in electrical, mechanical and screening can be limited accomodated. Contact Advanced Analog with specific requirements. www.irf.com 1 10/08/02 ATR28XXT Series Specifications TCASE = -55C to +125C, VIN = +28V 5% unless otherwise specified ABSOLUTE MAXIMUM RATINGS Input Voltage Range Power Dissipation Lead Temperature Storage Temperature 1 -0.5V to 50VDC Internal limited 37.5W +300C -65C to 150C case Conditions -55C TC +125C, VIN = 28 VDC 5%, CL=0, unless otherwise specified ATR2812T Min Max ATR2815T Min Max Units Test Symbol STATIC CHARACTERISTICS OUTPUT 1 Voltage VOUT Current Ripple 1,2,3,4 IOUT VRIP 1,5 IOUT = 0 (main) +25C over temp. range 1 IOUT = 0 (dual) +25C over temp. range VIN = 16, 28, and 40VDC (main) VIN = 16, 28, and 40VDC (dual)1 VIN = 16, 28, and 40VDC (dual) BW = 20Hz to 2MHz (main) VIN = 16, 28, and 40 VDC BW = 20Hz to 2 MHz (dual) VIN = 16, 28, and 40 VDC POUT = .5, 10, 20W (main) VIN = 16, 28, and 40 VDC(dual) 12 POUT = 0, 5, 10W (dual) VIN = 16, 28, and 40 VDC POUT = .5, 10, 20W (main) VIN = 16, 28, and 40 VDC 12 POUT = o, 5, 10W (dual) IOUT = 0, inhibit (pin 8) Tied to input return (pin 10) IOUT = 0, inhibit (pin 8) = open IOUT = 4000mA (main) 12 POUT = 10W (dual) BW = 20Hz to 2MHz IOUT = 4000mA (main) +25C 12 POUT = 10W (dual) over temp. range Input to output or any pin to case 4.95 4.90 11.88 11.76 100.0 0.0 5.05 5.10 12.12 12.24 4000 625 60 40 25 60 50 60 4.95 4.90 14.85 14.70 100.0 0.0 5.05 5.10 15.15 15.30 4000 500 60 40 25 75 50 75 VDC VDC VDC VDC mA mA mVp-p mVp-p REGULATION 1,3 Line VRLINE mV mV mV mV Load 1,3 VRLOAD INPUT Current 4 IIN IRIP EFF ISO 3 15 75 15 75 mA mA Ripple Current 50 75 72 100 14 9 600 700 13 +500 +1000 200 5 10 75 72 100 50 EFFICIENCY mAp-p % ISOLATION Load Fault Power Dissipation Switching Frequency SYNC Frequency Range Inhibit Open Circuit Voltage Output Response to Step transient 7 Load changes Recovery Time Step Step transient 7,8 Load changes PD FS FSYNC VOI VOTLOAD TTLOAD (except pin 8)at 500 TC=+25C Overload Short circuit 50% load to/from 100% load no load to/from 50% load 500 500 9 500 500 9 -500 -1000 14 9 600 700 13 +500 +1000 200 5 10 M W W KHz KHz V mVpk 50% load to/from 100% load No load to/from 50% load 50% load to/from 100% load No load to 50% load 50% load to no load -500 -1000 s ms ms For Notes to Specifications, refer to page 3 2 www.irf.com ATR28XXT Series Specifications TCASE = -55C to +125C, VIN = +28V 5% unless otherwise specified ABSOLUTE MAXIMUM RATINGS Input Voltage -0.5V to 50VDC Power Output Internally limited, 17.5W typical Soldering 300C for 10 seconds 6 Operating -55C to +135C case Temperature Range Storage -65C to +135C Conditions -55C TC +125C, VIN = 28 VDC 5%, CL=0, unless otherwise specified ATR2812T ATR2815T Test Symbol Min STATIC CHARACTERISTICS Output Response to 9 Transient step 10 Line changes Recovery Time 9 Transient step 10 Line changes 1 Turn on Overshoot Turn on Delay 1, 11 8 Max Min Max Units VOTLINE TTLINE VTonOS TonD Load Fault Recovery 10 Input step 16 from/to 40 VDC IOUT = 4000mA (main) POUT = 10W (dual) Input step 16 from/to 40 VDC IOUT = 4000mA (main) POUT = 10W (dual) IOUT = 0, and 4000mA (main) POUT = 0, 10W (dual) IOUT = 0, 4000mA (main) POUT = 0, 10W (dual) 1500 1500 mV pk 10 1000 25 25 10 1000 25 25 ms mV pk ms ms TRLF Notes to Specifications Tested at each output. Parameter guaranteed byline and load regulation tests. Although operation with no load is permissible, light loading on the main (+5 volt) output may cause the output voltage of the auxiliary outputs (12 volt or 15 volt) to drop out of regulation. It is therefore recommended that at least 100mA or 20 percent of the output power, whichever is greater, be taken from the main (+5 volt) output. 4. Total combined output power -30 watts. 5. Bandwidth guaranteed by design. Tested for 20KHz to 2MHz. 6. An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the overload protection circuit and is the condition of maximum power dissipation. 7. Load step transition time between 2 and 10 microseconds. 8. Recovery time is measured from the initiation of the transient to where VOUT has returned to within 1 percent of VOUT at 50 percent load. 9. Input step transition time between 2 to 10 microseconds. 10. Parameter shall be tested as part of design characterization and after design or process changes. Thereafter parameters shall be guaranteed to the limits specified in the table. 11. Turn on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the inhibit pin (pin 8) while power is applied to the input. 1. 2. 3. www.irf.com 3 ATR28XXT Series ATR28XXT Block Diagram 5 + V ou t 1 + In put EMI F ilter T ra ckin g R eg ula to r 8 E na ble 7 C as e 9 S yn c In put R eturn 10 P rim ary H ou sekee ping S up ply 4 -V out 2 + V ou t D rive 3 R eturn E rror Amp & R ef P uls e W idth FB M odulator CS 4 www.irf.com ATR28XXT Series ATR28XXT Case Outline 1.000 0.040 D X 0.26 L P ins 0.05 10 1 9 2 4 X 0.400 = 1.600 1.95 2.360 2.700 M ax 8 3 7 4 6 Pin Designation Pin No. 1 2 3 4 5 6 7 8 9 10 Designation Positive Input +5VDC Output Output Return Negative Dual Output Positive Dual Output N/C Case Ground Enable Input Sync Input Input Return 5 0.410 M ax 1.350 M ax Part Numbering ATR 28 15 T F / CH Model Input Voltage 28 = 28V Nominal Screening - , ES, HB, CH Package Style F = Flange Output Voltage 12 = 5V,12V: 15 = 5V,12V: Outputs T = Triple S = Single D = Dual www.irf.com 5 ATR28XXT Series Available Screening Levels and Process Variations for ATR28XXT Series Requirement Temperature Range Element Evaluation Internal Visual Temperature Cycle Constant Acceleration Burn-in Final Electrical (Group A) Seal, Fine & Gross External Visual MIL-STD-883 Method No Suffix -20 to +85C ES Suffix -55C to +125C HB Suffix -55C to +125C CH Suffix -55C to +125C MIL-PRF-38534 2017 1010, Cond C 2001, Cond A 1015 MIL-PRF38534 1014 2009 Yes Cond B 500g 48hrs @ 85C 25C 48hrs @ 125C 25C Yes Yes 5,000 g 160hrs @ 125C -55, +25, +125C Yes Yes 5,000 g 160hrs @ 125C -55, +25, +125C Yes Yes Yes Yes Yes Yes * Per Commercial Standards Available Standard Military Drawing (SMD) Cross Reference Standardized Military drawing PIN 5962-9315801HXX 5962-9315801HZX 5962-9215901HXX 5962-9215901HZX Vendor CAGE Code 52467 52467 52467 52467 Vendor Similar PIN ATR2812T/CH ATR2812TF/CH ATR2815T/CH ATR2815TF/CH WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 322 3331 ADVANCED ANALOG: 2270 Martin Av., Santa Clara, California 95050, Tel: (408) 727-0500 Visit us at www.irf.com for sales contact information. Data and specifications subject to change without notice. 10/02 6 www.irf.com |
Price & Availability of ATR2812
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |